A Study on the Reference Building based on the Building Design Trends for Non-residential Buildings (건축물 설계현황 분석을 통한 국내 비주거용 표준건물의 설정에 관한 연구)

  • Jeong, Young-Sun;Jung, Hae-Kwon;Jang, Hee-Kyung;Yu, Ki-Hyun
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.3
    • /
    • pp.1-11
    • /
    • 2014
  • The Korean government plans to introduce the building energy performance standard which regulates the annual energy consumption of buildings. This paper aimed to set up the reference building from database based on the building design trends for non-residential buildings. We surveyed the design data of 435 non-residential buildings which were granted building permission from 2007 to 2011. And we conducted estimation on the heating & cooling load and the energy consumption of the reference building using ECO2 program. From results, the reference building of non-residential buildings was office building which had a total 7 floors and $20,838m^2$ gross floor area. And it suggests the design reference data of building envelope, HAVC, heat source equipment and lighting system for the reference building. The total annual energy use of the reference building was $151.9kWh/m^2yr$.

A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building (제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구)

  • Sung, Uk-Joo;Rim, Min-Yeop;Kim, Seok-Hyun;Cho, Soo
    • Journal of Korean Institute of Architectural Sustainable Environment and Building Systems
    • /
    • v.12 no.6
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

A Study on Development of New Assessment Method for the Energy Performance in G-SEED using Dynamic Building Energy Simulation Programs (동적 건물에너지 시뮬레이션을 이용한 G-SEED 에너지성능 평가지침 도입 방안에 관한 기초연구)

  • Kim, Kee Han;Chae, Chang-U;Cho, Dongwoo
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.10
    • /
    • pp.27-35
    • /
    • 2018
  • In this paper, a fundamental study for developing and introducing a new assessment method of the 'Energy Performance' in G-SEED that uses dynamic building energy simulations was conducted by comparing and analyzing the corresponding issues of domestic and foreign green building certification systems. The most significant part of the new assessment method to be developed was a development of a modeling guideline for a reference building using dynamic building energy simulations. In this paper, the composition and detailed contents of the guideline was created to comply with domestic energy codes. In addition, one of the most influential part of the result in the simulations, the 24-hour building operation schedule for a reference building, was created considering the equity with the ECO2 program that is the evaluation tool of one of the current assessment methods in the "Energy Performance". In order to improve the completeness of this guideline, it is necessary to continue the process of supplementation in the future, however, this paper is expected to be of great significance as the beginning of the research.

Research on Relationship between Natural Vibration Periods and Structural Heights for High-rise Buildings and Its Reference Range in China

  • Xu, Peifu;Xiao, Congzhen;Li, Jianhui
    • International Journal of High-Rise Buildings
    • /
    • v.3 no.1
    • /
    • pp.49-64
    • /
    • 2014
  • Natural vibration period is an important parameter for high-rise building, Based on 414 high-rise buildings completed or passed over-limit approval in China, the distribution law of natural vibration periods is analyzied. In order to satisfy the design requirements, such as global stability, story drift limit and minimum shear-gravity ratio, the reference ranges of fundamental periods $T_1$ are $0.3{\sqrt{H}}{\sim}0.4{\sqrt{H}}$ when the structural heights $H{\geq}250m$, when 150 m ${\leq}$ H < 250m, $T_1=0.25{\sqrt{H}}{\sim}0.4{\sqrt{H}}$, when 100 m ${\leq}$ H < 150 m, $T_1=0.2{\sqrt{H}}{\sim}0.35{\sqrt{H}}$, when 50 m $ {\leq}$ H < 100m, $T_1=0.15{\sqrt{H}}{\sim}0.3{\sqrt{H}}$. These can provide reference data for controlling mass and rigidity of high-rise buildings.

A Study on the Design Guideline based Reference Plane for Standardization in Material of the Multi-family housing (공동주택 자재표준화를 위한 조립기준면 설계기준에 관한 연구)

  • Park, Geun-Soo;Lim, Seok-Ho;Ji, Jang-Hun
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.241-244
    • /
    • 2008
  • This study focused on the checking of design guideline using concept of reference plane as a promoting tool in order to apply to practical affair in relation to material standardization in housing build. For this purpose, we above all defined the role of reference plane. After establishing structural type can correspond to planning module of building components and coordination condition, we did exemplicated the sub-detail of building components which be to detach according to design method using the concept of reference plane that be complexed with spacial territory and replace cycle of building component or material.

  • PDF

A Study on Development of BIM Library for Unit Modular Housing - Focused on Small-sized Urban-life-housing - (유닛모듈러 주택의 BIM 라이브러리 개발 연구 - 소규모 도시형 생활주택을 중심으로 -)

  • Lee, Chang-Jae;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.23 no.6
    • /
    • pp.11-20
    • /
    • 2012
  • This Study developed library of parts, applied with 3-dimension character which has width, length and height and a reference plane, for the system development of BIM design on housing unit modular. The current BIM software has not the concept of a reference plane or work tolerance in modular, so the development of parts library applied to unit modular has not moved forward. So, we developed, in this study, parts library applied to windows, built-in-furniture, kitchen systems and knock down bathrooms, with a reference plane and work tolerance based on single roon prototype on urban-life-housings. BIM library can utilize changed size and work tolerance of parts, and fabricating reference plane will be created automatically when an engineer puts work tolerance in the BIM library with supplement of some category related to work reference. Through this BIM library development, we consider the part module can be used for housing complex planning, and architectural designers will be able to utilize the BIM library for housing complex design.

Building a Model of Digital Reference Services (디지털참고봉사 모형 구축에 관한 연구)

  • Kim, hwi-Chool
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.35 no.3
    • /
    • pp.117-133
    • /
    • 2001
  • This study presented the necessity of the development of a digital reference service systems as a method for direct information service in the library on the internet. The purpose of this research is to find commonalities for building a model of digital reference service. This study used qualitatives methods(elite interviews and document analysis) to extract accumulated knowhow from fourteen expert services sites which are similar with reference services in the library. For effective management of the digital reference service, it is necessary to have a digital reference service librarian who is well versed in the inner workings of the service and in the knowledge the service deals with.

  • PDF

Fast and Accurate Visual Place Recognition Using Street-View Images

  • Lee, Keundong;Lee, Seungjae;Jung, Won Jo;Kim, Kee Tae
    • ETRI Journal
    • /
    • v.39 no.1
    • /
    • pp.97-107
    • /
    • 2017
  • A fast and accurate building-level visual place recognition method built on an image-retrieval scheme using street-view images is proposed. Reference images generated from street-view images usually depict multiple buildings and confusing regions, such as roads, sky, and vehicles, which degrades retrieval accuracy and causes matching ambiguity. The proposed practical database refinement method uses informative reference image and keypoint selection. For database refinement, the method uses a spatial layout of the buildings in the reference image, specifically a building-identification mask image, which is obtained from a prebuilt three-dimensional model of the site. A global-positioning-system-aware retrieval structure is incorporated in it. To evaluate the method, we constructed a dataset over an area of $0.26km^2$. It was comprised of 38,700 reference images and corresponding building-identification mask images. The proposed method removed 25% of the database images using informative reference image selection. It achieved 85.6% recall of the top five candidates in 1.25 s of full processing. The method thus achieved high accuracy at a low computational complexity.

A Study on Building a Web-based Reference Resources Site (웹 기반 참고정보원 사이트의 구축에 관한 연구)

  • 문정순
    • Journal of Korean Library and Information Science Society
    • /
    • v.30 no.4
    • /
    • pp.229-254
    • /
    • 1999
  • As the number of Web reference resources are gradually increasing, reference librarians have to create a Web-based reference resources site. This site includes links to the Web reference resources of good quality, so that reference librarians and users will become accustomed to using these resources. This Study first explores the function of the Web-based reference resources site. Next, it carries out a survey of the current trends in america and Korea. Finally, a model Web-based reference resources site for academic libraries is developed.

  • PDF

A Study on the Control of Apartment House Design Factors considering Energy, Environment and Economical Efficiency (에너지, 환경 및 경제성을 통합 고려한 공동주택 설계요소 제어에 관한 연구)

  • Choi, Doo-Sung;Do, Jin-Seok
    • KIEAE Journal
    • /
    • v.12 no.6
    • /
    • pp.29-38
    • /
    • 2012
  • The current building energy efficiency rating certification regulation on apartment houses evaluates only the saving rate of energy consumed during operation, i.e. use, of a building, but doesn't consider the energy consumptions and environmental load($CO_2$) emissions occurring during the whole lifetime of a building. So this study calculated the energy consumptions and environmental load emissions occurring during the whole lifetime of a building, selected reference schemes and alternative items by design variables to present a design draft considering energy efficiency and environmental performance, and evaluated the total cost by combining and calculating its direct cost(material and heating cost) and indirect cost(environmental cost), for an existing apartment house as an evaluation object. As a result of analysis, the change of heating cost by alternative items of design variables showed a 4~8% change rate compared to the reference scheme, and the material cost of design variable 7 showed a maximum 4.4 times change rate in the alternative plan 6 compared to the reference scheme. The environmental cost showed a similar change rate to the material cost change rate in general, but showed a similar environmental cost change rate to the heating cost change rate in case of design variables 4-1, 4-2, 7.