• 제목/요약/키워드: Seismic Design Category

검색결과 29건 처리시간 0.019초

Development of classification criteria for non-reactor nuclear facilities in Korea

  • Dong-Jin Kim;Byung-Sik Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권2호
    • /
    • pp.792-799
    • /
    • 2023
  • Non-reactor nuclear facilities are increasing remarkably in Korea combined with advanced technologies such as life and space engineering, and the diversification of the nuclear industry. However, the absence of a basic classification guideline related to the design of non-reactor nuclear facilities has created confusion whenever related projects are carried out. In this paper, related domestic and international technical guidelines are reviewed to present the classification criteria of non-reactor nuclear facilities in Korea. Based on these criteria, the classification of structures, systems and components (SSCs) for safety controls is presented. Using the presented classification criteria, classification of a hot cell facility, a representative non-reactor nuclear facility, was performed. As a result of the classification, the hot cell facility is classified as the hazard category 3, accordingly, the safety class was classified as non-nuclear safety, the seismic category as non-seismic (RW-IIb), and the quality class as manufacturers' standards (S).

KBC 2005 내진설계 주요 개정사항 (Significant Changes in the Seismic Design Provisions of the 2005 KBC)

  • 정광량;유병억
    • 기술사
    • /
    • 제38권5호
    • /
    • pp.5-9
    • /
    • 2005
  • The seismic design provisions of the 2005 KBC has been based on the 2000 IBC and has considered the building code situations in Korea. There are site ground motion, soil class, seismic design category in the significant changes of the 2005 KBC. In the case of soft soil condition, the response spectrum acceleration of the 2005 KBC is larger than that of previous code. To reduce the seismic force of the 2005 KBC, it need to introduce the eqrthauke force resisting system with high ductility.

  • PDF

5층 철근콘크리트 중간모멘트골조의 비탄성 시간이력해석 (Inelastic Time History Analysis of a 5-Story Reinforced Concrete IMRF)

  • 강석봉;임병진
    • 한국지진공학회논문집
    • /
    • 제16권6호
    • /
    • pp.13-20
    • /
    • 2012
  • In this study, 5-story structures were designed in accordance with KBC2009 for inelastic time history analysis of RC IMRF. Bending moment-curvature relationship for beam and column was identified with fiber model and bending moment-rotation relationship for beam-column joint was calculated with simple and unified joint shear behavior model and moment equilibrium relationship for the joint. The hysteretic behavior was simulated with three-parameter model suggested in IDARC program. The analytical results showed that the inelastic shear behavior of the joint could be neglected in the structural design for seismic design category C but the structure of category D did not satisfy the criteria of FEMA 356 for collapse prevention performance level.

Estimation of response reduction factor of RC frame staging in elevated water tanks using nonlinear static procedure

  • Lakhade, Suraj O.;Kumar, Ratnesh;Jaiswal, Omprakash R.
    • Structural Engineering and Mechanics
    • /
    • 제62권2호
    • /
    • pp.209-224
    • /
    • 2017
  • Elevated water tanks are considered as important structures due to its post-earthquake requirements. Elevated water tank on reinforced concrete frame staging is widely used in India. Different response reduction factors depending on ductility of frame members are used in seismic design of frame staging. The study on appropriateness of response reduction factor for reinforced concrete tank staging is sparse in literature. In the present paper a systematic study on estimation of key components of response reduction factors is presented. By considering the various combinations of tank capacity, height of staging, seismic design level and design response reduction factors, forty-eight analytical models are developed and designed using relevant Indian codes. The minimum specified design cross section of column as per Indian code is found to be sufficient to accommodate the design steel. The strength factor and ductility factor are estimated using results of nonlinear static pushover analysis. It was observed that for seismic design category 'high' the strength factor has lesser contribution than ductility factor, whereas, opposite trend is observed for seismic design category 'low'. Further, the effects of staging height and tank capacity on strength and ductility factors for two different seismic design categories are studied. For both seismic design categories, the response reduction factors obtained from the nonlinear static analysis is higher than the code specified response reduction factors. The minimum dimension restriction of column is observed as key parameter in achieving the desired performance of the elevated water tank on frame staging.

시설물별 지진응답계측기 설치 운영에 관한 기준 및 지침 (Standard and Guideline for Installation and Management of Earthquake Instruments for Each Facilities)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.458-467
    • /
    • 2000
  • The standard of performance-based seismic design accepted by Ministry of Construction and Transport requires to install and manage earthquake instruments for the facilities of seismic category I and to acquire earthquake response data of these facilities at earthquake events. So detailed standard and guideline for installation and management of earthquake instruments for each facilities according to the seismic design standard are getting ready. This paper presents the part of installation locations of sensors in that detaile standard and guideline.

  • PDF

Seismic fragility analysis of base isolation reinforced concrete structure building considering performance - a case study for Indonesia

  • Faiz Sulthan;Matsutaro Seki
    • Structural Monitoring and Maintenance
    • /
    • 제10권3호
    • /
    • pp.243-260
    • /
    • 2023
  • Indonesia has had seismic codes for earthquake-resistant structures designs since 1970 and has been updated five times to the latest in 2019. In updating the Indonesian seismic codes, seismic hazard maps for design also update, and there are changes to the Peak Ground Acceleration (PGA). Indonesian seismic design uses the concept of building performance levels consisting of Immediate occupancy (IO), Life Safety (LS), and Collapse Prevention (CP). Related to this performance level, cases still found that buildings were damaged more than their performance targets after the earthquake. Based on the above issues, this study aims to analyze the performance of base isolation design on existing target buildings and analyze the seismic fragility for a case study in Indonesia. The target building is a prototype design 8-story medium-rise residential building using the reinforced concrete moment frame structure. Seismic fragility analysis uses Incremental Dynamic Analysis (IDA) with Nonlinear Time History Analysis (NLTHA) and eleven selected ground motions based on soil classification, magnitude, fault distance, and earthquake source mechanism. The comparison result of IDA shows a trend of significant performance improvement, with the same performance level target and risk category, the base isolation structure can be used at 1.46-3.20 times higher PGA than the fixed base structure. Then the fragility analysis results show that the fixed base structure has a safety margin of 30% and a base isolation structure of 62.5% from the PGA design. This result is useful for assessing existing buildings or considering a new building's performance.

Performance-based seismic evaluation and practical retrofit techniques for buildings in China

  • Wang, Hao;Sun, Baitao;Chen, Hongfu
    • Earthquakes and Structures
    • /
    • 제22권5호
    • /
    • pp.487-502
    • /
    • 2022
  • China is prone to earthquake disasters, and the higher seismic performance is required by many existing civil buildings. And seismic evaluation and retrofit are effective measures to mitigate seismic hazards. With the development of performance-based seismic design and diverse retrofit technology for buildings, advanced evaluation methods and retrofit strategies are in need. In this paper, we introduced the evolution of seismic performance objectives in China combined with performance-based seismic design. Accordingly, multi-phase evaluation methods and comprehensive seismic capacity assessment are introduced. For buildings with seismic deficiency or higher performance requirements, the retrofit technologies are categorized into three types: component strengthening, system optimization, and passive control. Both engineering property and social property for the retrofit methods are discussed. The traditional seismic retrofit methods usually are costly and disturbing, and for example in Beijing, seismic strengthening costs approx. 1000 RMB/m2 (for 160 USD/m2), for hospital building even more expensive as 5000 RMB/m2(for 790 USD/m2). So cost-efficient and little disturbance methods are promising techniques. In the end, some opinions about the retrofit strategy and schemes category are shared and wish to discuss the situation and future of seismic retrofit in China.

수직비정형과 비틀림비정형을 동시에 가지는 저층 RC 건물의 내진성능에 관한 연구 (Study on the Seismic Performance for Low-rised RC Building with Vertical and Torsional Irregularities)

  • 최인혁;백은림;이상호
    • 대한건축학회논문집:구조계
    • /
    • 제35권12호
    • /
    • pp.137-148
    • /
    • 2019
  • Korean piloti-type buildings are comprised of pilotis in the first story and shear walls in the upper stories. This vertical irregularity causes excessive lateral plastic deformation on the first story while the upper stories stay elastic. Meanwhile, asymmetric position of structural components such as core walls and columns of RC piloti-type buildings tends to produce torsional irregularities of the structures. Korean Building Code(KBC2016) requires the special seismic load and torsional amplification factor to apply to the piloti-type buildings lower than six-story or 20m if it has vertical and torsional irregularities when the building corresponds to seismic design category C or D. Many Korean low-rised RC buildings fall into the class. Therefore, the special earthquake load and torsional amplification factor are often applied to a building simultaneously. However, it has not been studied enough how much influence each parameter has on buildings with vertical and torsional irregularities at the same time. The purpose of this study is to evaluate the effect of factor special seismic load and torsional amplification on seismic performance of irregular buildings. In this study, a damaged 4th story piloti-type building by the Pohang earthquake was selected and the earthquake response analysis was carried out with various seismic design methods by the KBC 2016. The effect of the design parameters on seismic performance was analyzed by the dynamic analysis of models with special seismic load and torsional amplification factor based on the selected building. It was concluded that the application of the torsional amplification factor to the reference model to which special seismic design was applied, does not significantly affect the seismic performance.

지반주기를 고려한 다층지반의 평균전단파속도 추정 방법 평가 (Evaluation of Average Shear-wave Velocity Estimation Methods of Multi-layered Strata Considering Site Period)

  • 김동관
    • 한국지진공학회논문집
    • /
    • 제23권3호
    • /
    • pp.191-199
    • /
    • 2019
  • To calculate proper seismic design load and seismic design category, the exact site class for construction site is required. At present, the average shear-wave velocity for multi-layer soil deposits is calculated by the sum of shear-wave velocities without considering of vertical relationship of the strata. In this study, the transfer function for the multi-layered soil deposits was reviewed on the basis of the wave propagation theory. Also, the transfer function was accurately verified by the finite element model and the eigenvalue analysis. Three methods for site period estimation were evaluated. The sum of shear-wave velocities underestimated the average shear-wave velocities of 526 strata with large deviations. The equation of Mexican code overestimated the average shear-wave velocities. The equation of Japanese code well estimated the average shear-wave velocities with small deviation.

연구용 원자로 내부에 설치되는 이차정지구동장치의 내진낙하성능 (Seismic Drop Performance for Second Shutdown Drive Mechanism Installed in Research Reactor)

  • 김상헌;김경호;선종오;조영갑;김정현;정택형;이관희
    • 한국소음진동공학회논문집
    • /
    • 제26권6_spc호
    • /
    • pp.697-704
    • /
    • 2016
  • The second shutdown drive mechanism (SSDM) that is classified into seismic category I as an active mechanical equipment shall maintain the structural integrity and its designed inherent safety functions during and/or after normal operation, anticipated operational occurrences, accidents and seismic occurrences. Therefore, not only a structural integrity assessment through numerical analyses but also a qualification test by using the prototype SSDM shall be conducted to verify the adequacy of the SSDM design. This paper describes a sort of seismic qualification test of the prototype SSDM to demonstrate that the structural integrity and operability (functionality) of SSDM are maintained during and/or after seismic excitations. From the results, this paper shows that the SSDM satisfies all design requirements without any malfunctions during and after the seismic test.