• 제목/요약/키워드: Ventilator

검색결과 565건 처리시간 0.027초

공기흐름을 이용한 무동력 환풍장치 개발 (Development of Ventilator without Power using Air Flow)

  • 김범석;권택주;정지현
    • 동력기계공학회지
    • /
    • 제20권2호
    • /
    • pp.26-31
    • /
    • 2016
  • The studies on the efficient ventilator to reduce fire and save energy have been proceeded actively. The purpose of this paper is to design a ventilator used in residential wood stove. The ventilator consists of rotation and support part, and it is operated by natural wind without power. The shape of rotation part of the ventilator is like airfoil to reinforce pressure drop. We designed direction controller for the rotation part to track the direction of wind continuously. The rotation and support part have point-contact each other to minimize a friction. We verify the properties of the proposed ventilator though simulation and experiment. The results show the proposed ventilator can exhaust safely combustion gas of the stove more than other ventilator.

인공호흡기 회로 교환주기가 인공호흡기 관련 폐렴에 미치는 영향에 관한 메타 분석 (A Meta-Analysis of the Ventilator Circuit Change Period on Ventilator-Associated Pneumonia)

  • 송주현;김경희
    • 임상간호연구
    • /
    • 제16권3호
    • /
    • pp.111-121
    • /
    • 2010
  • Purpose: This meta-analysis was aimed to investigate the evidence of proper period of the ventilator circuit change using existing research. Methods: For this study, 14 published studies between 1995 and 2010 were tested by Macaskill, Funnel Plot, the Odds Ratio of DerSimonian and Laird, Fisher and Liptak analysis. Results: There were no publication bias found in the subjects. The results of the meta-analysis demonstrated no statistically significant differences were observed in neither the Odds Ratio (OR=1.18, 95% CI=0.94-1.47) of the frequency of ventilator-associated pneumonia and the mortality based on the period of the ventilator circuit change (Fisher p=.332, Liptak p=.498), nor the ventilation duration of ventilator (Fisher p=.843, Liptak p=.506), and the hospital length of stay (Fisher p=.254, Liptak p=.480). Conclusion: In order to present more concrete guidelines on the period of the ventilator circuit change, further research is warranted to thoroughly control confounding variables which related to the periods of the ventilator circuit change.

회로 교환주기에 따른 인공호흡기 관련 폐렴발생률 차이 (Ventilator-associated Pneumonia with Circuit Changes Every 7 Days versus Every 14 Days)

  • 최정실;연정화
    • 대한간호학회지
    • /
    • 제40권6호
    • /
    • pp.799-807
    • /
    • 2010
  • Purpose: To determine whether the practice of not routinely changing ventilator circuits in patients who require prolonged mechanical ventilation is associated with ventilator-associated pneumonia (VAP). Methods: Patients were divided into two groups, ventilator circuits were routinely changed every 7 days for the control group (39) and every 14 days for the experimental group (40) over a period of 1 yr (April 1, 2009-March 31, 2010). Pediatric patients (age 17 yr or less) were not included. VAP was diagnosed by the criteria of the Centers of Disease Control and Prevention (CDC). Incidence of VAP and characteristics of infection were evaluated. Results: In the experimental group, 2 episodes of pneumonia were observed in 40 patients and 1,322 ventilator days. The rate of VAP was 1.5 per 1,000 ventilator days. There was 1 episode of pneumonia in 39 patients and 481 ventilator days for the control group. The rate of VAP was 2.1 per 1,000 ventilator days. The difference between both groups was not significant (p=.695). Conclusion: Extending ventilator circuit change interval from 7 days to 14 days does not increase the risk for VAP.

Cardiac function associated with home ventilator care in Duchenne muscular dystrophy

  • Lee, Sangheun;Lee, Heeyoung;Eun, Lucy Youngmin;Gang, Seung Woong
    • Clinical and Experimental Pediatrics
    • /
    • 제61권2호
    • /
    • pp.59-63
    • /
    • 2018
  • Purpose: Cardiomyopathy is becoming the leading cause of death in patients with Duchenne muscular dystrophy because mechanically assisted lung ventilation and assisted coughing have helped resolve respiratory complications. To clarify cardiopulmonary function, we compared cardiac function between the home ventilator-assisted and non-ventilator-assisted groups. Methods: We retrospectively reviewed patients with Duchenne muscular dystrophy from January 2010 to March 2016 at Gangnam Severance Hospital. Demographic characteristics, pulmonary function, and echocardiography data were investigated. Results: Fifty-four patients with Duchenne muscular dystrophy were divided into 2 groups: home ventilator-assisted and non-ventilator-assisted. The patients in the home ventilator group were older ($16.25{\pm}1.85years$) than those in the nonventilator group ($14.73{\pm}1.36years$) (P=0.001). Height, weight, and body surface area did not differ significantly between groups. The home ventilator group had a lower seated functional vital capacity ($1,038{\pm}620.41mL$) than the nonventilator group ($1,455{\pm}603.2mL$). Mean left ventricular ejection fraction and fractional shortening were greater in the home ventilator group, but the data did not show any statistical difference. The early ventricular filling velocity/late ventricular filling velocity ratio ($1.7{\pm}0.44$) was lower in the home ventilator group than in the nonventilator group ($2.02{\pm}0.62$. The mitral valve annular systolic velocity was higher in the home ventilator group (estimated ${\beta}$, 1.06; standard error, 0.48). Patients with Duchenne muscular dystrophy on a ventilator may have better systolic and diastolic cardiac functions. Conclusion: Noninvasive ventilator assistance can help preserve cardiac function. Therefore, early utilization of noninvasive ventilation or oxygen may positively influence cardiac function in patients with Duchenne muscular dystrophy.

내과계중환자실에서 인공호흡기관련 폐렴 번들 적용의 효과 (Impact of the Ventilator-associated Pneumonia Bundle in a Medical Intensive Care Unit)

  • 유송이;정재심;최상호;김미나
    • Journal of Korean Biological Nursing Science
    • /
    • 제20권4호
    • /
    • pp.205-213
    • /
    • 2018
  • Purpose: The purpose of this study was to confirm the compliance of the application of a ventilator-associated pneumonia bundle and understand its effects on the decrease in the incidence of ventilator-associated pneumonia. Methods: This was a retrospective observational study with history control group design. Subjects were selected from January to June 2014, prior to the intervention using the ventilator-associated pneumonia bundle. Subjects were also selected from October 2014 to March 2015, 3 months after the intervention. The number of subjects was 112 before the intervention, and 107 after the intervention. Results: The number of nurses who followed the bundles increased from 8 out of 29 (27.6%) before the intervention to 19 out of 29 (65.5%) after the intervention (odd ratio= 4.99, confidence interval= 1.63-15.25, p= .004). There were 3 cases of ventilator-associated pneumonia before the intervention and 1 case after the intervention. The ventilator days were 2,143 days before the intervention and 2,232 days after the intervention. The ventilator-associated pneumonia rate of the 1,000 ventilator days was 1.40 before the intervention and decreased to 0.45 after the intervention. Conclusion: This study is meaningful, as there has been little research conducted regarding the application of the ventilator-associated pneumonia bundle in South Korea.

전열교환 환기시스템의 외기변화에 따른 성능평가 및 에너지평가를 통한 운전방안에 관한 연구 (A Study on Operating Method by Energy Evaluation and Performance Evaluation of Heat Recovery Ventilator According to Outdoor Conditions)

  • 김광현;이정재
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.57-64
    • /
    • 2008
  • Recently, regulation of ventilator installation and its details has been revised and the establishment of heat recovery ventilator in newly built apartments has been obligated. This study was done to offer the method of operation and design of heat recovery ventilator to save energy by measuring its efficiency and comparing with the results of experiment. This paper confirmed that it is desirable to operate heat recovery ventilator by using "by-pass mode" within $60{\sim}80%$ scope of the difference indoor absolute humidity in spring and autumn and outdoor absolute humidity and heat recovery ventilator of energy saving effect is better than constant air volume system.

인공호흡기 튜브교환주기에 따른 인공호흡기 관련 폐렴발생률 (The Incidence Rate of Ventilator Associated Pneumonia in Relation to the Exchange of Circuit Cycle)

  • 김남초;김양리
    • 성인간호학회지
    • /
    • 제15권3호
    • /
    • pp.463-471
    • /
    • 2003
  • Purpose: This study was aimed at providing scientific evidence for minimizing ventilator-associated pneumonia(VAP) by identifying appropriate timing of exchange of circuit for mechanical ventilator that is well suitable for the medical environment of intensive care units of hospitals in Korea. Method: This was a quasi-experimental study with a convenience sample of 19 adult subjects aged over 18 years who were admitted to the NS ICU of C university hospital, and placed on mechanical ventilator. The subjects were placed in two groups, compared on the incidence rate of VAP after they received exchange of circuit either at 1-week interval (N =10) or 2-week interval (N = 9). Result: 1) When considering 1000 days as the standard unit of analysis for incidence, the incidence rate of VAP was 7.19 cases at the 1-week cycle exchange group and 15.23 at the 2-week cycle exchange group, showing no statistically significant difference between the two groups. 2) There were a total of 3 types of bacteria isolated from the patients with VAP, including 2 cases with P. aeruginosa, 1 case with Streptococcus group F and A. baumannii. Conclusion: With thorough hand washing and strict management of tracheal tube of mechanical ventilator as well as use of tracheal intubation techniques, exchange cycle of circuit of mechanical ventilator by nurses may be changed from 1-week to 2-week interval.

  • PDF

자연환기 벤틸레이터 형태에 따른 환기효율 평가 (Evaluation of Ventilation Efficiency for Various Gravity Ventilators)

  • 하현철;김태형
    • 설비공학논문집
    • /
    • 제14권7호
    • /
    • pp.543-551
    • /
    • 2002
  • Gravity ventilators allow the escape of the warm air and air contaminants due to both (either) buoyancy and (or) convection. As a natural ventilation strategy, various gravity ventilators can be installed on the roof. Ventilation efficiency could be affected by various parameters, such as, area of openings, wind velocity and incidence angle, temperature difference between inside and outside, and shape of ventilator. Especially, the shape of roof gravity ventilator might be one of influencing factors for the effective ventilation. The window type gravity ventilators are frequently installed instead of general (standard) gravity ventilator. However, the ventilation efficiencies of them were not proved yet. To compare the ventilation efficiency, general type ventilator and two window type ventilators were numerically tested. Mean age of air, temperature and CO concentration were predicted by using commercial CFD code, AIRPAK (Ver. 2.0) with various conditions. The predicted result showed that general type ventilator is more effective for natural ventilation than window type ventilators.

고층건축물에서의 연돌효과에 따른 배연창의 배연성능에 관한 기초적 연구 (A Basical Study about Ventilation Performance of Natural Smoke Ventilators through Stack Effect in High-rise Building)

  • 김혜원;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2017년도 추계 학술논문 발표대회
    • /
    • pp.54-55
    • /
    • 2017
  • The High-rise building has a problem the ventilation performance of natural ventilator by stack effect that it occurs by pressure difference. For that reason the study about natural smoke ventilator of High-rise building consistently needs. Therefore on this study does analysis of difference with abroad through investigate of Natrual smoke ventilator's law, it conducts of natural smoke ventilator's research on the actual condition. As a result on this study, in the case of abroad that it states more specific standards than domestic. Also the result of a field study, it shows that the natural smoke ventilator is installed same size and the number regardless of building's pressure difference.

  • PDF

의료진의 가정용 인공호흡기 관련 지식 정도와 교육요구도 조사 (A Survey on Nurses' and Physicians' Knowledge and Educational Needs on Home Ventilator)

  • 조수현;고명균;정진희;원선영;이희옥;남지명;위미숙;이영희
    • 중환자간호학회지
    • /
    • 제5권1호
    • /
    • pp.56-66
    • /
    • 2012
  • Purpose: The purpose of this study was to investigate the knowledge and educational needs of nurses and physicians on home ventilator. Methods: The participants were 140 nurses and 47 physicians working at departments using home ventilators. The data were collected from January 30 to February 12, 2012 through a self-administered questionnaire with 32 items of the knowledge and educational needs on home ventilator. Results: The mean scores of nurses' and physicians' knowledge were 2.52 and 2.56 respectively. The mean scores of nurses' and physicians' educational needs were 3.16 and 3.06 respectively. Nurses' knowledge was associated with their experience using and receiving education about home ventilator and willingness to receive education about home ventilator education. Nurses' educational needs were associated with their present working department and experience using home ventilator. Nurses with high knowledge were more likely to have high educational needs. Physicians' knowledge and educational needs were not associated with any their general characteristics. Conclusion: Nurses' and physicians' knowledge of home ventilator were low and their educational needs on home ventilator were high. To provide high quality of care for home ventilators, it is necessary to provide nurses and physicians with education and to develop a more specific educational program for them.

  • PDF