• Title/Summary/Keyword: bioelectrical impedance analysis

검색결과 141건 처리시간 0.03초

Bioelectrical Impedance Analysis on the Paretic and Non-paretic Regions of Severe and Mild Hemiplegic Stroke Patients

  • Yoo, Chanuk;Yang, Yeongae;Baik, Sungwan;Kim, Jaehyung;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권2호
    • /
    • pp.115-125
    • /
    • 2017
  • For many stroke patients undergoing rehabilitation therapy, there is a need for indicator for evaluating the body function in paretic and non-paretic regions of stroke patients quantitatively. In this paper, the function of muscles and cells in paretic and non-paretic regions of severe and mild hemiplegic stroke patients was evaluated using multi-channel bioelectrical impedance spectroscopy. The paretic and non-paretic regions of severe and mild stroke patients were quantitatively assessed by using bioelectrical impedance parameters such as prediction marker (PM), phase angle (${\theta}$), characteristic frequency ($f_c$), and bioelectrical impedance vector analysis (BIVA). The mean values of impedance vector were significantly discriminated in all comparisons (severe-paretic, severe-non-paretic, mild-paretic, and mild-non-paretic). The bioelectrical impedance parameters were proved to be a very valuable tool for quantitatively evaluating the paretic and non-paretic regions of hemiplegic stroke patients.

Bioelectrical Impedance Analysis at Inner Forearms of the Human Body using Bioelectrical Impedance Measurement System

  • Kim, Jae-Hyung;Kim, Soo-Hong;Baik, Sung-Wan;Jeon, Gye-Rok
    • 한국멀티미디어학회논문지
    • /
    • 제19권7호
    • /
    • pp.1146-1153
    • /
    • 2016
  • The bioelectrical impedance (BI) at the inner forearms was measured using bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, while applying a constant alternating current of 800A to the inner region of the forearms, BI (Z) was measured at nineteen frequencies ranging from 5 to 500 kHz. The prediction marker (PM) was calculated for right and left forearm. The resistance (R) and the reactance (Xc) were simultaneously measured during impedance measurement. Second, a Cole-Cole plot (relationship between reactance and resistance) was obtained for left and right forearm, indicating the different characteristic frequencies (fc). Third, the phase angle was obtained, indicating strong dependence on the applied frequency.

Impedance Parameter Variations at Intravenous (IV) Infiltration Using Bioelectrical Impedance: A Pilot Study

  • Kim, Jaehyung;Lee, Mansup;Baik, Seungwan;Kim, Gunho;Hwang, Youngjun;Jeon, Gyerok
    • 한국멀티미디어학회논문지
    • /
    • 제20권10호
    • /
    • pp.1678-1688
    • /
    • 2017
  • Infiltration is one of detrimental problems occurring in nursing or medical settings. Early detection of infiltration is essential to minimize the risk of injury from infiltration. To perform a preliminary study on the point of care and automated infiltration detection system, bioelectrical impedance was investigated using bioelectrical impedance analyzer. We would like to report experimental results that allow impedance parameters to effectively distinguish infiltration. Electrodes were attached to both sides of the transparent dressing on the fusion site where IV solution was being infused. Then, impedance parameters before and after infiltration were measured as a function of time and frequency. The experimental results are as follows. After infiltration was intentionally induced by puncturing the vein wall with a needle, the resistance gradually decreased with time. That is, when an alternating current having a frequency of 20 kHz was applied to the electrodes, the resistance gradually decreased with time, reflecting the accumulation of IV solution in the extracellular fluid since the current could not pass through the cell membrane. Impedance parameters and equivalent circuit model for human cell were used to examine the mechanism of current flow before and after infiltration, which could be used for early detection of infiltration.

생체 전기 임피던스 분석의 한의학적 적용을 위한 연구동향 (Review on Bioelectrical Impedance Analysis in Traditional East Asian Medicine)

  • 배장한;김영민;김근호;김재욱
    • 동의생리병리학회지
    • /
    • 제27권6호
    • /
    • pp.717-729
    • /
    • 2013
  • Bioelectrical Impedance Analysis (BIA) is a non-invasive and low-cost technique that estimates body composition based on the distribution of water and electrolytes in the body by analyzing body's electrical responses to source voltages. In this work, we carried out a systematic literature review on BIA researches in traditional East Asian medicine (TEAM). For comparison, firstly we introduced the concept and principle of BIA, and offered a general overview of research trends in western medical perspectives. We searched through the databases of Oriental Medicine Advanced Searching Integrated System and DataBase Periodical Information Academic for the articles published between 1994 and 2013, with keywords such as 'BIA', 'bioelectrical impedance' and 'impedance'. Among the rough-searched 274 articles, we finally selected 21 articles appropriate to the intended research field. The selected articles were categorized into diagnosis in Sasang medicine, impedance analysis in meridian system, and change of body composition after taking herbal medicine. We found that most of BIA researches in TEAM were preliminary and remained in the peripheral levels which is far behind the western medical research activities. Therefore, more efforts are needed to study BIA in association with major subjects such as pattern identification or physiological/pathological phenomena. In addition, methodological breakthrough of BIA is possible by applying the diagnostic concepts of the TEAM in relation to the balance of Qi and Blood.

Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS

  • Kim, J.H.;Kim, S.S.;Kim, S.H.;Baik, S.W.;Jeon, G.R.
    • 센서학회지
    • /
    • 제25권1호
    • /
    • pp.1-7
    • /
    • 2016
  • Bioelectrical impedance (BI) at popliteal regions was measured using a bioelectrical impedance measurement system (BIMS), which employs the multi-frequency and the two-electrode method. Experiments were performed as follows. First, a constant AC current of $800{\mu}A$ was applied to the popliteal regions (left and right) and the BI was measured at eight different frequencies from 10 to 500 kHz. When the applied frequency greater than 50 kHz was applied to human's popliteal regions, the BI was decreased significantly. Logarithmic plot of impedance vs. frequency indicated two different mechanisms in the impedance phenomena before and after 50 kHz. Second, the relationship between resistance and reactance was obtained with respect to the applied frequency using BI (resistance and reactance) acquired from the popliteal regions. The phase angle (PA) was found to be strongly dependent on frequency. At 50 kHz, the PA at the right popliteal region was $7.8^{\circ}$ slightly larger than $7.6^{\circ}$ at the left popliteal region. Third, BI values of extracellular fluid (ECF) and intracellular fluid (ICF) were calculated using BIMS. At 10 kHz, the BI values of ECF at the left and right popliteal regions were $1664.14{\Omega}$ and $1614.08{\Omega}$, respectively. The BI values of ECF and ICF decreased sharply in the frequency range of 10 to 50 kHz, and gradually decreased up to 500 kHz. Logarithmic plot of BI vs. frequency shows that the BI of ICF decreased noticeably at high frequency above 300 kHz because of a large decrease in the capacitance of the cell membrane.

Comparison of Infiltration Induced in Veins of Rabbit's Ear and Human's Forearm by Using Bioelectrical Impedance: Pilot Study

  • Kim, Jae-Hyung;Hwang, Young-Jun;Kim, Gun-Ho;Shin, Beum-Joo;Kim, Yong-Jin;Lee, Eun-Joo;Jeon, Gye-Rok
    • 센서학회지
    • /
    • 제26권5호
    • /
    • pp.306-313
    • /
    • 2017
  • An early detection of infiltration in veins is essential to minimize the injuries caused during infusion therapy, which is one of the most important tasks for nurses in clinical settings. We report that bioelectrical impedance analysis is useful in the early detection of infiltration at puncture sites. When infiltration was intentionally induced in the vein of a rabbit's ear, impedance parameters showed significant difference before and after infiltration. In particular, the relative resistance at 20 kHz in the vein of rabbit's ear reduced largely at infiltration, decreased slowly, and then stayed at a constant value. This indicates that the vein in the ear of the rabbit is small, and hence the infiltrated intravenous (IV) solution no longer accumulates after 3 minutes of infiltration. However, when infiltration was induced in the vein of a human's forearm, the relative resistance at 20 kHz decreased gradually over time. In the $R-X_c$ graph, the positions in infiltration induced in the rabbit's ear rapidly shifted before and after infiltration whereas the positions in infiltration induced in the human's forearm changed gradually during infiltration. Our findings suggest that bioelectrical impedance analysis is an effective method to detect the infiltration early in a noninvasive and quantitative manners.

생체 전기 신호에 의한 효율적인 생체 신호 측정 (Effective Body Signal Measurement with the Bioelectric Impedance Analysis)

  • 오세용;황대석;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 춘계종합학술대회
    • /
    • pp.955-958
    • /
    • 2005
  • 생체 전기 임피던스법(Bioelectrical Impedance Analysis, BIA)은 신체의 체수분량을 측정하고 이를 바탕으로 체지방량을 측정할 수 있다. 여기에 사용된 상관식은 FFM=-4.104+0.518H+0.231W+0.130X+4.229S를 사용하였다. 여기서 H는 신장, R은 저항값, W는 체중, X는 리액턴스이고 S는 성별이다.

  • PDF

효율적인 생체 임피던스 신호 측정에 관한 연구 (Effective Body Signal Measurement with the Bioelectric Impedance Analysis)

  • 오세용;이영우
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2005년도 추계종합학술대회
    • /
    • pp.689-692
    • /
    • 2005
  • 생체 전기 임피던스법(Bioelectrical Impedance Analysis, BIA)은 신체의 체수분량을 측정하고 이를 바탕으로 체지방량을 측정할 수 있다. 이를 효율적으로 측정하기 위해서 4개의 전극을 손바닥에 위치 시키고 전류(50kHz, 800uA)를 신체에 흘려 보내 전압과 캐패시턴스를 측정하고 기본 파라미터인 키, 몸무게, 나이와 성별을 입력하여 체지방량을 측정하는 방법을 제안하였다.

  • PDF

Predicting body compositions of live finishing pigs based on bioelectrical impedance analysis

  • An, Ji Seon;Lee, Ji Hwan;Song, Min Ho;Yun, Won;Oh, Han Jin;Kim, Yong Ju;Lee, Jun Soeng;Kim, Hyeun Bum;Cho, Jin Ho
    • Journal of Animal Science and Technology
    • /
    • 제63권2호
    • /
    • pp.332-338
    • /
    • 2021
  • The objective of this study was to predict body compositions of live pigs using bioelectrical impedance procedures. In experiment 1, 32 crossbred (Duroc × Landrace × Yorkshire) finishing pigs with an average weight at 84.06 kg were used. In experiment 2, 96 crossbred (Duroc × Landrace × Yorkshire) finishing pigs with an average weight at 88.8 kg were used. A four-terminal body composition analyser was utilized to determine fat percentage. Lean meat percentage and backfat thickness were measured with a lean meat measuring meter. In experiment 1, fat percentage was not significantly correlated with lean meat percentage, although a tendency (p < 0.1) of a negative correlation was found. Backfat thickness was significantly correlated with fat percentage and lean meat percentage (r = 0.745 and r = -0.961, respectively). Coefficients of determination for fat percentage with lean meat percentage, fat percentage with backfat thickness, and backfat thickness with lean meat percentage were 0.503, 0.566, and 0.923, respectively. In experiment 2, fat percentage was significantly correlated with lean meat percentage (r = -0.972). Backfat thickness was also significantly correlated with fat percentage and lean meat percentage (r = 0.935 and r = -0.957, respectively). Results of this study indicate that bioelectrical impedance analysis might be useful for predicting body compositions of live finishing pigs.

분절임피던스를 기준한 분절다주파수 생체임피던스의 일치도 분석 (Validation of Segmental Multi-Frequency Bioelectrical Impedance Analysis based on the Segmental Bioelectrical Impedance analysis in the Elderly Population)

  • 탕새조;김장희;엄진종;엄선호;김학균;김철현
    • Journal of Platform Technology
    • /
    • 제9권2호
    • /
    • pp.38-45
    • /
    • 2021
  • 분절다중주파수 생체전기임피던스분석법(Segmental Multi-frequency Bioelectrical Impedance)은 최근 체성분 검사를 위해 선호되는 검사법이다. 그러나 SMF-BIA 는 팔다리와 몸통의 임피던스를 추정하는 방법으로 정확한 사용을 위해서는 타당성에 대한 확인이 요구된다. 본 연구는 SMF-BIA 를 인체의 분절임피던스를 기준하여 분절별 임피던스의 추정값에 대한 정확도와 타당도를 검정하는데 목적하였다. 연구목적을 위해 노인 108 명을 대상으로 50kHz 주파수에서 얻어진 분절별 생체전기 임피던스값에 대하여 분절 생체임피던스 측정치 비교하였다. 실험 결과 오른쪽 팔의 저항 값은 준거값에 비해 유의한 수준으로 높았다(저항값: 35.5±6.2%, P < 0.001; 리액턴스: 2.7±7.6%, P < 0.01). 왼쪽팔, 오른쪽 다리와 왼쪽다리의 생체저항값은 준거값에 비해 모두 유의하게 높았다. 몸통의 추정값은 기준값에 비해 가장 큰 차이를 보였다(저항값: 65.4±3.2%, P < 0.001; 리액턴스: 89.2±1.8%, P < 0.001). 두 방법으로 측정한 임피던스 결과에서 사지와 전신의 생체저항값은 높은 상관관계(RA: R = 0.950 LA: R = 0.949 RL: R = 0.899, LL: R = 0.888)를 보였으며, 팔과 다리에서도 유의한 상관관계를 보였다. 따라서 분절다주파수 생체임피던스는 준거와 높은 상관도와 함께 유의한 오차를 보여, 향후 오차 수준을 줄이기 위한 연구가 필요하였다.c