• 제목/요약/키워드: constant sum method

검색결과 69건 처리시간 0.024초

Aggregation of Measures of Effectiveness with Constant Sum Scaling Method and Multiple Regression

  • Kim, Hyung-Bae
    • 한국국방경영분석학회지
    • /
    • 제5권2호
    • /
    • pp.27-38
    • /
    • 1979
  • This method explores a method of aggregating the measures of effectiveness of a weapon system from its characteristics. With this method, the constant sum method and multiple regression are used to develop a functional relationship between system effectiveness and system characteristics. As an example, a study of a tank weapon system was${\cdot}$conducted with data from the U.S. Army Armor School. It was concluded that the aggregation method is feasible, and that for the tank system studied, the reciprocals of system characteristics give a good estimating equation for measuring tank system effectiveness.

  • PDF

구획모델을 이용한 주택에서 이산화질소의 발생강도 및 감소상수 동시 추정 (Estimation of Source Strength and Deposition Constant of Nitrogen Dioxide Using Compartment Model)

  • 양원호;손부순;손종렬
    • 한국환경보건학회지
    • /
    • 제31권4호
    • /
    • pp.260-265
    • /
    • 2005
  • Indoor air quality might be affected by source strength of indoor pollutants, ventilation rate, decay rate, outdoor level, and so on. Although technologies measuring these factors exist directly, direct measurements of all factors are not always practical in most field studies. The purpose of this study was to develop an alternative method to estimate the source strength and deposition constant by application of multiple measurements. For the total duration of 60 days, indoor and outdoor $NO_2$ concentrations every 3 days were measured in 30 houses in Seoul, Asan and Daegu. Using a compartment model by mass balance and linear regression analysis, penetration factor (ventilation divided by sum of air exchange rate and deposition constant) and source strength factor (emission rate divided by sum of air exchange rate and deposition constant) were calculated. Subsequently, the source strength and deposition constant were estimated. Natural ventilation was $1.80{\pm}0.42\;ACH,\;1.11{\pm}0.50\;ACH,\;0.92{\pm}0.26\;ACH$ in Seoul, Asan and Daegu, respectively. Calculated deposition constant(K) and source strength of $NO_2,$ in this study were $0.98{\pm}0.28\;hr^{1}\;and\;16.28{\pm}7.47\;ppb/h,$ respectively.

Estimation of NO$_2$ Source Generation and Ventilation rate in Residence by Multiple Measurements

  • Won Ho, Yang;Gi Yeong, Lee
    • 한국환경과학회:학술대회논문집
    • /
    • 한국환경과학회 2003년도 봄 학술발표회 발표논문집
    • /
    • pp.155-160
    • /
    • 2003
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor $NO_2$ concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential $NO_2$ deposition constant of 1.05 $hr^{-1}$, and 1.36 ACH in Seoul, with the measured residential $NO_2$ deposition constant of 0.94 $hr^{-1}$. Source strengths of $NO_2$ were 15.8 $\pm$ 18.2 ${\mu}g$/$m^3$.hr and 44.7 $\pm$ 38.1${\mu}g$/$m^3$.hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

Estimation of Nitrogen Dioxide Source Generation and Ventilation Rate in Residence Using Multiple Measurements in Korea

  • Chung, Moon-Ho;Yang, Won-Ho
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2004년도 International Conference Current Challenges and Advances in Environmental Health
    • /
    • pp.45-50
    • /
    • 2004
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Alt hough technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Daily indoor and outdoor NO2 concentrations were measured for 30 consecutive days in 28 houses in Brisbane, Australia, and for 21 consecutive days in 37 houses in Seoul, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and NO2 source strength were estimated. Geometric means of ventilation rate were 1.44 ACH in Brisbane, assuming a residential NO2 deposition constant of 1.05 hr-1, and 1.36 ACH in Seoul, with the measured residential NO2 deposition constant of 0.94 hr-1. Source strengths of N02 were 15.8 ${\pm}$ 18.2 ${\mu}$g/m3${\cdot}$hr and 44.7 ${\pm}$ 38.1 ${\mu}$g/m3${\cdot}$hr in Brisbane and Seoul, respectively. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF

HE NONCOMMUTATIVE ℓ1 - ℓ2 INEQUALITY FOR HILBERT C*-MODULES AND THE EXACT CONSTANT

  • Krishna, K. Mahesh;Johnson, P. Sam
    • Nonlinear Functional Analysis and Applications
    • /
    • 제27권2호
    • /
    • pp.249-259
    • /
    • 2022
  • Let 𝓐 be a unital C*-algebra. Then it follows that $\sum\limits_{i=1}^{n}(a_ia^*_i)^{\frac{1}{2}}{\leq}\sqrt{n}\(\sum\limits_{i=1}^{n}a_ia^*_i\)^{\frac{1}{2}}$, ∀n ∈ ℕ, ∀a1, …, an ∈ 𝓐. By modifications of arguments of Botelho-Andrade, Casazza, Cheng, and Tran given in 2019, for certain n-tuple x = (a1, …, an) ∈ 𝓐n, we give a method to compute a positive element cx in the C*-algebra 𝓐 such that the equality $$\sum\limits_{i=1}^{n}(a_ia^*_i)^{\frac{1}{2}}=c_x\sqrt{n}\(\sum\limits_{i=1}^{n}a_ia^*_i\)^{\frac{1}{2}}$$ holds. We give an application for the integral of Kasparov. We also derive a formula for the exact constant for the continuous ℓ1 - ℓ2 inequality.

주택 실내.외 이산화질소 측정을 이용한 환기량 및 발생량 추정 (Estimation of Ventilation and Generation Rates Using Nitrogen Dioxide Measurements of Indoor and Outdoor in Houses)

  • 양원호;임성국;손부순
    • 한국환경과학회지
    • /
    • 제17권10호
    • /
    • pp.1069-1073
    • /
    • 2008
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, the ventilation rate and $NO_2$ generation rate were estimated. Mean of ventilation rate was 1.41 ACH in houses, assuming a residential N02 deposition constant of 0.94 $hr^{-1}$. Mean generation rate of $NO_2$ was 16.5 ppbv/hr. According to house characterization, inside smoking and family number were higher $NO_2$ generation rates, and apartment was higher than single-family house. In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

비선형 시스템에 대한 T-S 퍼지 모델 구성 (Construction of T-S Fuzzy Model for Nonlinear Systems)

  • 정은태;권성하;이갑래
    • 제어로봇시스템학회논문지
    • /
    • 제8권11호
    • /
    • pp.941-947
    • /
    • 2002
  • Two methods of constructing T-S fuzzy model which is equivalent to a given nonlinear system are presented. The first method is to obtain an equivalent T-S fuzzy model by using the sum of linearly independent scalar functions with constant real matrix coefficients. The sum of products of linearly independent scalar functions is used in the second method. The former method is to formulate the procedures of T-S fuzzy modeling dealt in many examples of previous publications; the latter is a new method. By comparing the number of linearly independent functions used in the two methods, we can easily find out which method makes fewer rules than the other. The nonlinear dynamics of an inverted Pendulum on a cart is used as an equivalent T-5 fuzzy modeling example.

다중 프레임의 SAD를 이용한 드론 속도 측정 (Estimation of Drone Velocity with Sum of Absolute Difference between Multiple Frames)

  • 남돈호;염석원
    • 융합신호처리학회논문지
    • /
    • 제20권3호
    • /
    • pp.171-176
    • /
    • 2019
  • 드론은 원거리 동영상을 효율적으로 획득할 수 있어서 활용성이 높다. 드론 운용에서 속도의 크기인 속력은 설정할 수 있지만 이동하는 방위의 정확한 값은 설정이 불가능하다. 본 논문에서는 드론에서 획득한 동영상을 이용하여 일정한 속도로 이동하는 드론의 속도를 추정한다. 기준 프레임과 표적 프레임의 Sum of Absolute Difference(SAD)를 최소로 하는 표적 프레임의 변위를 구한다. 드론의 실제 속도(Ground Truth)는 각 프레임에서 일정한 동일 지점(Matching Point)의 위치를 이용하여 계산한다. 실험에서 150m 상공에서 일정한 속력으로 이동하는 드론으로 동영상을 획득하였다. 추정한 x와 y방향의 속도와 속력의 평균 제곱근 오차(RMSE)를 구하여 제안한 방법의 신뢰성을 보였다.

가중치 산출방법에 따른 고객만족도지수의 비교 (Comparison of Customer Satisfaction Indices Using Different Methods of Weight Calculation)

  • 이상준;김용태;김성윤
    • 디지털융복합연구
    • /
    • 제11권12호
    • /
    • pp.201-211
    • /
    • 2013
  • 본 연구는 다양한 가중치 산출방법을 적용하여 각 차원별 가중치 및 고객만족도지수를 비교하고 시사점을 밝혀보고자 한다. 이를 위해 가중치 산출방법을 주관적 방법과 통계적 방법으로 구분하고, 다시 주관적 방법은 고정총합법, 그리고 통계적 방법은 상관분석, 회귀분석, 주성분분석, 요인분석, 구조방정식으로 세분화하였다. 연구결과 주관적 방법과 통계적 방법에 의한 가중치는 서로 차이가 있는 것으로 나타났고, 분석방법에 따른 가중치의 순위는 유사한 패턴으로 구분되었다. 그리고 가중치 산출방법에 따른 각 차원별 가중치는 큰 편차를 보여 차원간의 변별력 및 안정성에 차이를 나타냈다. 마지막으로 다양한 가중치 산출방법에 따른 고객만족도지수는 구조방정식, 회귀분석, 상관분석, 산술평균, 주성분분석, 고정총합법, 요인분석의 순으로 높게 나타났고, 각 방법론에 따른 고객만족도지수는 통계적으로 유의한 차이가 있는 것으로 나타났다.

Characterization of Indoor Air Quality Using multiple Measurements of Nitrogen Dioxide and Volatile Organic Compounds

  • Son, Bu-Soon;Yang, Won-Ho;Sohn, Jong-Ryeal;Kim, Dae-Won;Jung, Soon-Won;Kim, Young-Hee
    • 한국환경보건학회:학술대회논문집
    • /
    • 한국환경보건학회 2005년도 국제학술대회
    • /
    • pp.293-298
    • /
    • 2005
  • Indoor air quality can be affected by indoor sources, ventilation, decay and outdoor levels. Although technologies exist to measure these factors, direct measurements are often difficult. The purpose of this study was to develop an alternative method to characterize indoor environmental factors by multiple indoor and outdoor measurements. Indoor and outdoor NO$_2$ and VOCs(benzene, toluene, xylene) concentrations were measured every 3 days for 60 consecutive days in 30 houses in Seoul, Asan and Daegu, Korea. Using a mass balance model and regression analysis, penetration factor (ventilation rate divided by the sum of ventilation rate and deposition constant) and source strength factor (source strength divided by the sum of ventilation rate and deposition constant) were calculated using multiple indoor and outdoor measurements. Subsequently, NO$_2$ and VOCs source strengths (ppb/hr) and deposition constant (K, hr$^{-1}$) were estimated. Deposition constants of NO$_2$, toluene and xylene were 0.98 ${\pm}$ 0.28, 0.71 ${\pm}$ 0.24 and 0.74 ${\pm}$ 0.53 hr$^{-1}$, respectively. Source strengths of NO$_2$, toluene and xylene were 16.28 ${\pm}$ 7.47,31.25 ${\pm}$ 38.45 and 23.45 ${\pm}$ 19.67 ppb/hr, respectively In conclusion, indoor environmental factors were effectively characterized by this method using multiple indoor and outdoor measurements.

  • PDF