• Title/Summary/Keyword: drill rod

Search Result 6, Processing Time 0.021 seconds

Dynamic response of free-end rod with consideration of wave frequency

  • Kim, Sang Yeob;Lee, Jong-Sub;Tutumluer, Erol;Byun, Yong-Hoon
    • Geomechanics and Engineering
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2022
  • The energy transferred on drill rods by dynamic impact mainly determines the penetration depth for in-situ tests. In this study, the dynamic response and transferred energy of drill rods are determined from the frequency of the stress waves. AW-type drill rods of lengths 1 to 3 m are prepared, and strain gauges and an accelerometer are installed at the head and tip of the connected rods. The drill rods are hung on strings, allowing free vibration, and then impacted by a pendulum hammer with fixed potential energy. Increasing the rod length L increases the wave roundtrip time (2L/c, where c is the wave velocity), and hence the transferred energy at the rod head. At the rod tip, the first velocity peak is higher than the first force peak because a large and tensile stress wave is reflected, and the transferred energy converges to zero. The resonant frequency increases with rod length in the waveforms measured by the strain gauges, and fluctuates in the waveforms measured by the accelerometer. In addition, the dynamic response and transferred energy are perturbed when the cutoff frequency is lower than 2 kHz. This study implies that the resonant frequency should be considered for the interpretation of transferred energy on drill rods.

Experimental Evaluation of Percussion Performance for Rock-Drill Drifter

  • Seo, Jaho;Park, Jin-Sun;Kim, Heungsub;Noh, Dae Kyung
    • Journal of Biosystems Engineering
    • /
    • v.40 no.1
    • /
    • pp.1-9
    • /
    • 2015
  • Purpose: The objective of this study was to understand the operating mechanism of the rock-drill drifter, to explain how to setup an experimental test system and measure the strain of the drifter's rod, and to evaluate the drifter's performance with respect to the impact energy and blow frequency. Methods: The structure of the rock-drill drifter and its operating principle regarding the impact process were analyzed. Static calibration was carried out to calculate the correction factor using a drifter rod as the first step of the experimental test. The impact energy and blow frequency were then calculated based on strain measurements of the drifter's rod. Results: Experimental results showed that the tested drifter elicited a blow frequency of 3330 BPM (Blows Per Minute) and generated impact energy of 170 J/blow. This indicates that the drifter elicits a higher percussion speed and results in a lower impact energy compared to the hydraulic breaker at the same input power. Conclusions: The study proposed methodologies that deal with the experimental setup and the evaluation of the performance of the rock-drill drifter. These methodologies can be extensively used for validating and improving the percussion performance of the drilling equipment.

A Study on the Strength Evaluation of Micropile with Expanded Drill Hole (확공형 마이크로 파일의 강도 평가에 관한 연구)

  • Lee, Jae-Min;Kim, Doo-Hwan
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.5
    • /
    • pp.74-81
    • /
    • 2014
  • This study proposes an advanced type of a micropile system. The proposed micropile system consists of perfobond ribs installed steel rod to improve shear capacity between the thread and the grout, and partially expanded drill holes to increase resistance capacity between the grout and the ground. This study contains experimental evaluations on the proposed micropile system to verify the shear capacity of perfobond rib installed on the steel rod and the load-carrying capacity of shear key created by the partially expanded drill hole. Push-out tests were conducted on a rolled screw thread and steel rods which perfobond ribs are installed instead of rolled screw, in order to compare their load-carrying capacity and behavioral characteristics. As a result, it was confirmed that the perfobond-rib steel rods show much superior structural behavior in terms of initial stiffness, ultimate load, and ductile behavior.

An Experimental Study on Drilling Conditions for the Instrumentation of Nuclear Fuel (핵연료 계장을 위한 천공조건에 대한 실험적 연구)

  • Hong, Jintae;Kim, Ka-Hye;Jeong, Hwang-Young;Ahn, Sung-Ho;Joung, Chang-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.1
    • /
    • pp.113-119
    • /
    • 2013
  • To develop a new nuclear fuel, it needs to make a test fuel rod and carry out burn-up test in the test loop of a research reactor to check the irradiation characteristics of the nuclear fuel. At that time, several sensors such as thermocouples, LVDTs and SPNDs are needed to be attached in and out of the fuel rod and connect them with instrumentation cables. Then, the instrumentation cables deliver the signals measured by the sensors to the measuring device located outside of the reactor pool. In particular, to install a thermocouple in a fuel rod, it needs to drill off holes on the alumina blocks and sintered $UO_2$ pellets. However, because the hardness of a sintered $UO_2$ pellet is 700 Hv (or HRC 61) and that of an alumina block is 1480 Hv, a special drilling machine which adapts a diamond coated drill bit had developed. In this study, several case experiments have been carried out to find an optimal drilling condition of the drilling machine. And, using the optimal drilling condition, minimum numbers of the holes that a drill bit can drill off are verified.

Development of Precision Drilling Machine for the Instrumentation of Nuclear Fuels (핵연료계장을 위한 정밀 드릴링장치 개발)

  • Hong, Jintae;Jeong, Hwang-Young;Ahn, Sung-Ho;Joung, Chang-Young
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.30 no.2
    • /
    • pp.223-230
    • /
    • 2013
  • When a new nuclear fuel is developed, an irradiation test needs to be carried out in the research reactor to analyze the performance of the new nuclear fuel. In order to check the performance of a nuclear fuel during the irradiation test in the test loop of a research reactor, sensors need to be attached in and out of the fuel rod and connect them with instrumentation cables to the measuring device located outside of the reactor pool. In particular, to check the temporary temperature change at the center of a nuclear fuel during the irradiation test, a thermocouple should be instrumented at the center of the fuel rod. Therefore, a hole needs to be made at the center of fuel pellet to put in the thermocouple. However, because the hardness and the density of a sintered $UO_2$ pellet are very high, it is difficult to make a small fine hole on a sintered $UO_2$ pellet using a simple drilling machine even though we use a diamond drill bit made by electro deposition. In this study, an automated drilling machine using a CVD diamond drill has been developed to make a fine hole in a fuel pellet without changing tools or breakage of workpiece. A sintered alumina ($Al_2O_3$) block which has a higher hardness than a sintered $UO_2$ pellet is used as a test specimen. Then, it is verified that a precise hole can be drilled off without breakage of the drill bit in a short time.

CW Laser Generation form Nd;YAG Single Crystal Grown by Czochralski Method (Czochralski 방법으로 육성된 Nd:YAG 단결정으로부터 CW mode laser 의 발진)

  • 이상호;배소익;김한태;정수진
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1997.08a
    • /
    • pp.85-85
    • /
    • 1997
  • Czochralski 방법에 의해 육성된 Nd:YAG 단결정으로부터 CW mode의 1064nm laser를 발진시켰다. 육성된 단결정은 직경 50mm, 길이 120mm 이었으며, Nd 이온 농도는 O.2~0.9at% 이었다. 육성된 단결정 boule로 부터 결정학적 결함부위인 core 및 facet가 없는 양질의 단결정 부위를 Twyman-Green interferometer로 선빌하였다. 추출핀 부위는 절단, 가공, 연마공정 및 코팅 공정을 통해 직경 6.35mm, 길이 lOOmm의 laser rod를 제작하였다. 절단은 core drill, 또는 원통 연삭기를 사용하여 rod 형태로 가공하였으며, 상$\cdot$하면 polishing은 평행도 10", 직각도 5', 평활도 $\lambda$/10 수준까지 실험실에서 자체 가공하여 일반적인 laser 발진용 rod의 spec.을 만족시킬 수 있었다.

  • PDF