• Title/Summary/Keyword: engineering application

Search Result 26,628, Processing Time 0.047 seconds

The detection efficiency study of NaI(Tl) scintillation detector with the different numbers of SiPMs

  • Wang, Bao;Zhang, Xiongjie;Wang, Qingshan;Wang, Dongyang;Li, Dong;Xiahou, Mingdong;Zhou, Pengfei;Ye, Hao;Hu, Bin;Zhang, Lijiao
    • Nuclear Engineering and Technology
    • /
    • v.54 no.7
    • /
    • pp.2564-2571
    • /
    • 2022
  • SiPMs are generally coupled into whole columns in gamma energy spectrum measurement, but the relationship between the distribution of whole SiPM columns and the energy resolution of the measured energy spectra is rarely reported. In this work, ∅ 3 × 3 inch NaI scintillator is placed on an 8 × 8 SiPM array, and the energy resolution of the 137Cs peak at 662 keV corresponding to the γ-ray is selected as a reference. Each SiPM is switched to explore the influence of the number of SiPM arrays, distribution position, and reflective layer on the energy resolution of SiPMs. Results show that without coupling, the energy resolution is greatly improved when the number of SiPMs ranges from 4 to 32. However, after 32 slices (the area covered by SiPMs relative to the scintillator reaches 25.9%), the improvement in energy resolution and total pulse count is not obvious. In addition, the position of SiPMs relative to the scintillator does not exert much impact on the energy resolution. Results also indicate that by adding a reflective film (ESR), the energy resolution of the tested group increases by 10.38% on average. This work can provide a reference for the design and application of miniaturized SiPM gamma spectrometers.

A Modeling Tool for X-Window Application Software Development

  • Lee, Joon-Seok;Lee, Sang-Bum;Chi, Dong-Hae
    • ETRI Journal
    • /
    • v.15 no.2
    • /
    • pp.75-84
    • /
    • 1993
  • This paper presents a modeling tool, so-called X-ADD (X-window application Analysis & Design Diagram), which is useful for the understanding of existing X-window application program and the development of new X-window application software. This X-ADD tool is available for the X-window applications maintenance activities such as program understanding, and program analysis by the concept of reverse engineering. In addition, it supports the analysis and design for the new X-window application system development. Therefore, by the use of this tool, the visibility of the existing X-window application programs can be enhanced and modeling for the design of new X-window application systems can be easily made.

  • PDF

A Mobile Color-compensating Application using RGB Color Compensation Algorithm (RGB 색 보정 알고리즘을 활용한 모바일 색 보정 애플리케이션)

  • Kwak, Ki Hyun;Jun, Yong Chan;Choi, Sul In;Shin, Hee Jung;Hwang, Sung Soo
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.12
    • /
    • pp.1936-1942
    • /
    • 2016
  • This paper presents a mobile color-compensating application using a RGB color compensation algorithm. The proposed application enables color vision deficiencies to differentiate images which cannot be distinguished by them. The suggested mobile application has two functions: converting images taken by camera and converting contents in the device screen. The proposed application is computationally inexpensive, since it does not require color space transformation. Simulation results show that the proposed application enables color vision deficiencies to receive information expressed by colors such as subway line maps.

The Chaos Application of a Point of View Engineering Application (공학적 응용에서 바라본 카오스 응용)

  • Bae, Young-Chul
    • Journal of Information Management
    • /
    • v.31 no.3
    • /
    • pp.21-34
    • /
    • 2000
  • In recent year, much progress has been made in understanding the application of the chaos in the engineering. In the electrical engineering, electronics, communication, mechanical, chemistry as well as mathematics, physics, there are extended to the application of chaos. In this review, I explained chaos engineering application and future application possibility.

  • PDF

A Method of Information Management for BIM Based Building Permission (BIM기반 건축물 인허가 신청을 위한 정보 관리방안)

  • Yeo, ChangJae;Kim, Karam;Kim, Gutak;Yu, JungHo
    • Korean Journal of Computational Design and Engineering
    • /
    • v.21 no.3
    • /
    • pp.242-251
    • /
    • 2016
  • Around the world, BIM application has been mandated. In Korea, an announcement was made in 2016 that BIM application will be required for all public constructions ordered by the Public Procurement Service. However, BIM cannot be used for building permits as Seumter, a building permit system, doesn't support BIM, even if it was used for building design. To utilize BIM for permit application, this study introduces a method of management for BIM-used permit application information. It was done by analyzing the data entered for new building permit application in Seumter. For the analysis, the permit application information is classified as internal BIM information and external BIM information and the required information is defined. To easily create and utilize the data types at the design stage, this study introduces a method of creating and utilizing a permit template. Also, this study developed a tool for combining the area information to add up all the related information such as gross floor area and floor area ratio. This study is significant in that it analyzes the required information for new building permit application among all the permit application types in Korea.

Multi-channel analyzer based on a novel pulse fitting analysis method

  • Wang, Qingshan;Zhang, Xiongjie;Meng, Xiangting;Wang, Bao;Wang, Dongyang;Zhou, Pengfei;Wang, Renbo;Tang, Bin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.6
    • /
    • pp.2023-2030
    • /
    • 2022
  • A novel pulse fitting analysis (PFA) method is presented for the acquisition of nuclear spectra. The charging process of the feedback capacitor in the resistive feedback charge-sensitive preamplifier is equivalent to the impulsive pulse, and its impulse response function (IRF) can be obtained by non-linear fitting of the falling edge of the nuclear pulse. The integral of the IRF excluding the baseline represents the energy deposition of the particles in the detector. In addition, since the non-linear fitting process in PFA method is difficult to achieve in the conventional architecture of spectroscopy system, a new multi-channel analyzer (MCA) based on Zynq SoC is proposed, which transmits all the data of nuclear pulses from the programmable logic (PL) to the processing system (PS) by high-speed AXI-Stream in order to implement PFA method with precision. The linearity of new MCA has been tested. The spectrum of 137Cs was obtained using LaBr3(Ce) scintillator detector, and was compared with commercial MCA by ORTEC. The results of tests indicate that the MCA based on PFA method has the same performance as the commercial MCA based on pulse height analysis (PHA) method and excellent linearity for γ-rays with different energies, which infers that PFA method is an effective and promising method for the acquisition of spectra. Furthermore, it provides a new solution for nuclear pulse processing algorithms involving regression and iterative processes.

A field determination method of D-T neutron source yields based on oxygen prompt gamma rays

  • Xiongjie Zhang;Bin Tang ;Geng Nian;Haitao Wang ;Lijiao Zhang ;Yan Zhang ;Rui Chen ;Zhifeng Liu ;Jinhui Qu
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2572-2577
    • /
    • 2023
  • A field determination method for small D-T neutron source yield based on the oxygen prompt gamma rays was established. A neutron-gamma transport equation of the determination device was developed. Two yield field determination devices with a thickness of 20 mm and 50 mm were made. The count rates of the oxygen prompt gamma rays were calculated using three energy spectra processing approaches, which were the characteristic peak of 6.13 MeV, the overlapping peak of 6.92 MeV and 7.12 MeV, and the total energy area. The R-square of the calibration curve is better than 94% and the maximum error of the yield test is 5.21%, demonstrating that it is feasible to measure the yield of D-T neutron source by oxygen prompt gamma rays. Additionally, the results meet the requirements for field determination of the conventional D-T neutron source yield.