• Title/Summary/Keyword: filtration length

Search Result 40, Processing Time 0.022 seconds

A Study on Prediction of On-line Type Pulse Air Jet Bag Filter Effective Pulsing Distance (연속탈진형 충격기류식 여과집진장치의 여과포 유효탈진거리 예측)

  • Jeong-Sam Son;Jeong-Min Suh;Jeong-Ho Park
    • Journal of Environmental Science International
    • /
    • v.32 no.8
    • /
    • pp.555-561
    • /
    • 2023
  • A study is to predict the effective pulsing distance following to the pulsing pressure, nozzle diameter, filtration velocity using numercial analysis techniques and use it as an efficient operation condition and economic data for on-line type pulse air jet bag filter. Filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the primary experiments using coke dust. For CFD simulation, analysis pulsing characteristics about nozzle diameter, filtration velocity and pulsing pressure. The maximum pulsing length of on-line type pulse air jet bag filter, in 10mm nozzle, filtration velocity 1.5m/min and pulsing pressure 5 bar conditions, is 2,285 mm, maximum length is 76.2% of the total filter bag, which is sufficient to pulsing. In 12mm nozzle, pulsing pressure 5 bar and filtration area 1.22 m2 conditions, the maximum pulsing length of on-line type pulse air jet bag filter is 1,744~2,952 mm, and the maximum length is 2,952 mm indicates pulsing air can be reached to the bottom of filter bag. When the nozzle diameter is increased 8mm to 10mm, maximum pulsing length is extended 40~47%, and increased 10mm to 12 mm, maximum pulsing length is extended 10~17%. For effective pulsing, over the 5bar of pulsing pressure and larger than 10 mm of nozzle diameter are required.

Influence of Water Temperature and Salinity on Oxygen Consumption and Filtration Rate of on Oxygen Consumption and Filtration Rate of Ark Shell, Anadara granosa bisenensis

  • Kang, Kyoung-Ho;Kim, Jae-Min;Kim, Young-Hun
    • The Korean Journal of Malacology
    • /
    • v.20 no.2
    • /
    • pp.107-110
    • /
    • 2004
  • The filtration rate and oxygen consumption of Anadara granosa bisenensis were measured at 4 different temperature (10$^{\circ}C$, 15$^{\circ}C$, 20$^{\circ}C$, and 25$^{\circ}C$) and 4 different salinity levels (20, 25, 35, and 40 psu), using an direct method under laboratory conditions. The samples were divided into two groups: a large-sized group (shell length: 34.58 ${\pm}$ 2.23 mm, body weight: 12.43 ${\pm}$ 0.44 g) and a small-sized group (shell length: 20.60 ${\pm}$ 0.85 mm, body weight: 4.41 ${\pm}$ 2.30 g). Filtration rate and oxygen consumption increased with the increase of various temperatures and salinity levels. Also, the filtration rate and oxygen consumption of the small-sized group were higher than those of the large-sized group. These results indicate that the filtration rate and oxygen consumption of Anadara granosa bisenensis depends on environmental conditions, especially on water temperature and salinity.

  • PDF

Effect of Refining Load on the Drainage Characteristics of Pulp (고해부하가 지층 형성시 탈수특성에 미치는 영향)

  • 김용식;원종명
    • Journal of Korea Technical Association of The Pulp and Paper Industry
    • /
    • v.32 no.4
    • /
    • pp.10-17
    • /
    • 2000
  • The change of fiber length, freeness, initial forming drainage velocity, specific filtration resistance, final drainage time and wet web dryness were measured to investigate the effect of the refining load on the drainage characteristics of pulp. The arithmetic average fiber length after refining with higher refining load was shorter than that obtained with lower refining load. Higher refining load decreased initial forming drainage velocity, final drainage time and wet web dryness. The refining load also affected the relationship between freeness and specific filtration resistance, initial forming drainage velocity, final drainage time. It was found that the specific filtration resistance is better than freeness to predict the drainage characteristics of pulp and the wet dryness.

  • PDF

TORSION IN THE COHOMOLOGY OF FINITE H-SPACES

  • Choi, Young-Gi
    • Journal of the Korean Mathematical Society
    • /
    • v.39 no.6
    • /
    • pp.963-973
    • /
    • 2002
  • We study torsion phenomena in the integral cohomology of finite if-spaces X through the Eilenberg-Moore spectral sequence converging to H*($\Omega$X; Z$_{p}$). We also investigate how the difference between the Z$_{p}$-filtration length f$_{p}$(X) and the Z$_{p}$-cup length c$_{p}$(X) on a simply connected finite H-space X is reflected in the Eilenberg-Moore spectral sequence converging to H*($\Omega$X;Z$_{p}$). Finally we get the following result: Let p be an odd prime and X an n-connected finite H-space with dim QH* (X;Z$_{p}$) $\leq$ m. Then H*(X;Z) is p-torsion free if (equation omitted).tion omitted).

A Study on Backwashing of Granular Fiters Used in Water Treatment (정수처리를 위한 여과지의 역세척에 관한 연구)

  • Lee, Jung Taek;Ahn, Jong Ho;Choi, Keun Ho
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.13 no.3
    • /
    • pp.61-72
    • /
    • 1999
  • To obtain the experimental data for design and operation of actual filtration processes, a sand filter and three kinds of dual media filters in pilot-plant scale were operated in this study. We analyzed the effect of filter medium composition on the filter performance and the effects of backwash water flow rates, length of stream line and air flow rate on the filter backwash efficiency. We also compared the efficiencies of the combined air-water backwashing and the water backwashing in dual media filters. As the backwash water flow rates or the length of stream line increased, the final turbidity of backwash water was decreased and the filtration duration time after backwash was increased. In the case of the combined air-water backwashing, the backwash water quantity needed for backwashing the dual media filters could be decreased. The total volume of filtered water for the dual media filters during filter run was over three times larger than that for the sand filter. The dual media filters could be operated at a high filtration rate of 360 m/day.

  • PDF

Modeling of Particle Removal in the Coarse Media of Direct Horizontal-Flow Roughing Filtration (Direct Horizontal-Flow Roughing Filtration의 조립 여상에서의 입자 제거 모델링)

  • Ahn, Hyo-Won;Park, No-Suk;Lee, Sun-Ju;Lee, Kyung-Hyuk;Wang, Chang-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.338-347
    • /
    • 2005
  • Horizontal-Flow Roughing Filtration (HRF) is one of altemative pretreatment methods e.g. prior to Slow Sand Filtration (SSF). However, some of its limitations are that the effluent quality drops drastically at higher turbidity (>200 NTU) and at higher filtration rate (>1 m/h). To overcome these drawbacks, we suggested Direct Horizontal-Flow Roughing Filtration (DHRF), which is a modified system of Horizontal-Flow Roughing (HRF) by addition of low dose of coagulant prior to filtration. In this study to optimize the DHRF configuration, a conceptual and mathematical model for the coarse compartment has been developed in analogy with multi-plate settlers. Data from simple column settling test can be used in the model to predict the filter performance. Furthermore, the model developed herein has been validated by successive experiments carried out. The conventional column settling test has been found to be an handy and useful to predict the performance of DHRF for different raw water characteristics (e.g. coagulated or uncoagulated water, different presence of organic matter, etc.) and different inital process conditions (e.g. coagulant dose, mixing time and intensity, etc.). An optimum filter design for the coarse compartment (grain size 20mm) has been found to be of 3 m/h filtration rate with filter length of 4-4.5 m.

Site Suitability and Developable Amount Assessment for Riverbank Filtration in the Han River (II) (한강에서의 강변여과수 개발을 위한 적지선정 및 개발가능량 산정(II))

  • Lee, Sang-Il;Yoo, Sang-Yeon;Lee, Sang-Sin
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.8
    • /
    • pp.835-843
    • /
    • 2008
  • In Korea, riverbank filtration has drawn attention since 1990's as an alternative having potential to stably meet the ever-increasing water demand. Some cities located in the Nak-dong River Basin are currently supplying water through riverbank filtration. This research is on the application of riverbank filtration for stable water quality in Seoul. For this purpose, we have evaluated developable amount of water with riverbank filtration for the Han River. This paper focuses on the Kwangnaru site, which was selected through a systematic analysis in the companion paper. We have conducted groundwater modeling for a proposed system of wells and an artificial lake. In the Kwangnaru district, the river length to constitute a well system was identified to be about 1,200m, due to the topography and the field condition such as ecosystem preservation zone. After many design changes, it was found that the maximum developable amount of $23.36\;million\;m^3$/year could be obtained, when 16 pumping wells were built in every 80 meters along with an artificial lake upstream.

An Experimental Study on the Distributions of Residual Head and Discharge Rate along Collector Well Laterals of a Model Riverbed Filtration (하상여과의 집수관 모형에서 잔류수두와 유입율 분포에 관한 실험연구)

  • Ahn, Kyu-Hong;Moon, Hyung-Joon;Kim, Kyung-Soo;Kim, Seung-Hyun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.12
    • /
    • pp.1305-1310
    • /
    • 2005
  • As a way to the optimum design of the collector well lateral in riverbed filtration, experiments were performed using sand tanks which were connected to form a model lateral system. Measured were the residual hydraulic heads along the laterals, the discharge rates at each sand tank and the production rates at the collector well while the model laterals were operated with various scenarios of changing parameters including water level of the collector well, the lateral diameter and length, and the hydraulic conductivity of the sand. Results showed that riverbed filtration could be more efficient when the resistance in the lateral was weak compared with the resistance in the sand, which was indicated by the more flattened distribution of the residual hydraulic heads along the lateral. Results also showed that the discharge rate increased exponentially with the approach to the collector well, and that the exponent increased as the lateral diameter decreased and/or the hydraulic conductivity of the sand increased. It was also seen that the well production increased with the increase in the lateral length and diameter although the marginal productivity decreased. It could be concluded that the axial flow velocity in the lateral was an important factor governing the efficiency of a lateral in riverbed filtration and that the maximum entrance velocity to the collector well, over which the efficiency decreased drastically, was about 1 m/sec under the conditions of this study.

Development of Water-Source Heat Pump System Using Riverbank Filtration Water on the Waterfront (친수지역 강변여과수 열원을 활용한 냉난방시스템 개발)

  • Cho, Yong;Kim, Dea Geun;Moon, Jong-Pil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.201.2-201.2
    • /
    • 2011
  • A water-source heat pump system has been developed for cooling and heating of a green house on the waterfront in Jinju. In order to supply a heat source/sink of water in alluvium aquifer to the heat pump system, the riverbank filtration facility (two pumping wells and one recharge well) for water intake and injection has been constructed. To pump and recharge water sufficiently, the geometric design such as depth and diameter for the wells have been completed, and details of the well such as slot size and length of the screen and filter pack size have been designed based on the practical and theoretical design method including D30 technique. For the investigation of the hydrogeological characteristics, step-drawdown test, long-term pumping test, and recovery test have been carried out for two developed pumping wells. Step-drawdown test has been performed on 4 step flowrates of 150, 300, 450, $600m^3$/day for 1 hour, and long-term pumping test on flowrate of $500m^3$/day for 24 hours, and recovery test for 6 hours. Since the underground water filtrated by riverbank is flowing smoothly into the well, the water level goes down slightly for the long-term test. Consequently, the stable pumping flowrate for two pumping well has been predicted at least over $1,647m^3$/day which is larger than the flowrate of $1,000m^3$/day for a 60 RT heat pump system.

  • PDF

Prediction of Off-line Type Pulse Air Jet Bag Filter Reflection Distance (간헐탈진형 충격기류식 여과집진장치의 여과포 반사거리 예측)

  • Jeong-Sam Son;Yong-Hyun Chung;Jeong-Min Suh
    • Journal of Environmental Science International
    • /
    • v.32 no.11
    • /
    • pp.801-809
    • /
    • 2023
  • The purpose of this study is to predict the reflection distance following to the pulsing pressure, total air supplying, filter bag size using numercial analysis techniques and use it as an efficient operation condition and economic data for off-line type pulse air jet bag filter. In this research, filtration area 6 m2 condition, calculate filter resistance coefficient for simulation through the main experiments using coke dust. Ansys fluent V19.0 apply to CFD simulation, and analysis pulsing characteristics about pulsing pressure, filtration velocity and nozzle diameter. The maximum reflecting distance of off-line type pulse air jet bag filter is 1,000 mm regardless of total air supplying at over the 42 L/m2 conditions, that indicates off-line type can extend filter bag length 1,000 mm than on-line type. In order to effective primary and secondary pulsing of off-line type pulse air jet bag filter, over the 5 bar of pulsing pressure and over the 42 L/m2 of total air supplying are needed.