• 제목/요약/키워드: geometric mean diameter

검색결과 57건 처리시간 0.024초

흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경 (Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study)

  • 정재열;이기남
    • 동의생리병리학회지
    • /
    • 제17권5호
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

응축입자 발생기에서의 입자 발생특성에 관한 실험적 연구 (An Experimental Study on the Characteristics of Generated Particle using Homogeneous Condensation Particle Generator)

  • 김진호;김상수
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집B
    • /
    • pp.392-397
    • /
    • 2000
  • Mono-disperse particles generated by a condensation particle generator are widely used to meet the experimental and industrial needs. The characteristics of particles generated by homogeneous nucleation have been studied experimentally using a laminar flow condensation particle generator. Dry nitrogen gas saturated with oleic acid vapor was cooled well below the saturation temperature causing the highly supersaturated vapor to nucleate. The dependence of GSD(Geometric Standard Deviation), GMD(Geometric Mean Diameter), and the mass concentration of particles on the temperature at the evaporator, flow rate and the temperature condition at condenser was studied. The experimental results show that the mass concentration of particles is affected by the radial temperature profile at condenser. Nucleation at the center of the condenser causes the mass concentration of particles to increase. The experimental results also show that the suppression of additional nucleation by a constant temperature condition at the condenser increases the mean diameter of particle.

  • PDF

파쇄프랙탈차원을 이용한 밭토양 내수성입단과 대공극률의 관계 평가 (Relationship between Water Stable Aggregate and Macroporosity in Upland Soils Calculated by Fragmentation Fractal Dimension)

  • 한경화;조현준;이협성;허승오;하상건
    • 한국토양비료학회지
    • /
    • 제42권1호
    • /
    • pp.58-64
    • /
    • 2009
  • 본 연구는 밭토양 내수성입단의 계절별 특성을 밝히고 파쇄프랙탈차원을 이용하여 대공극률과의 관계를 구명코자 수행하였다. 대상 토양은 토성이 다른 세 지점으로 고평통 (Fine, Typic Hapludalfs), 규암통 (Fine silty over coarse silty, Fluvaquentic Eutrudepts), 중동통(Coarse loamy, Typic Udifluvents)으로 경기도에 위치하였다. 봄, 여름, 가을에 불교란 시료를 채취하고 내수성입단과 대공극률, 토양이화학성을 측정하였다. 내수성입단은 파쇄프랙탈차원($D_f$), 기하평균지름(GMD), 중량평균지름(MWD)의 세 가지로 계수화하였다. $D_f$는 MWD보다 GMD와 상관이 높게 나타났고, 무차원의 입단파쇄과정에 근거하여서 실험에 사용한 입단크기와 전처리과정의 영향을 덜 받아 내수성입단의 계수화에 적절하다고 판단할 수 있었다. 계절적으로 내수성입단은 여름>봄>가을순으로 나타났고 생물활성과 토양수분의 영향으로 파악할 수 있었다. $D_f$ 3.1이하의 토양에서 $D_f$와 대공극률과역의 상관관계를 나타냈으며 특히 $99{\mu}m$ 이상의 공극률과 상관이 높았으며 $D_f$ 3.1이상의 토양에서는 상관이 나타나지 않았다. 또한 $D_f$ 3.1이하의 토양에서는 대공극률과 포화수리전도도의 누승함수 적합도가 높게 나타났다. 따라서 내수성입단의 파쇄프랙탈차원은 입단화에 의한 대공극형성과 해석에 유용하다고 판단할 수 있었다.

CWM의 미립화특성에 대한 실험적 연구 (An Experimental Study on the Atomization Characteristics of Coal-Water-Mxture)

  • 김윤태;전영남;채재우
    • 대한기계학회논문집
    • /
    • 제14권5호
    • /
    • pp.1330-1336
    • /
    • 1990
  • The factors to act on atomization of liquid fuel are viscosity, geometric shape of nozzle, atomizing pressure, etc. Most of high viscous liquid fuels show decrease in viscosity by raising the preheat temperature, but the viscosity of liquid fuel like CWM does not readily change with fuel temperature. As an experimental study to investigate the atomizing characteristics of CWM, CWM fuel is atomizing with a twin-fluid atomizer, and the effects of the geometric shape of spray nozzle on atomization are investigated by measuring the Sauter`s Mean Diameter (SMD) of CWM. The summarized results obtained in this study are as follows ; (1) As the ratio of the mass flows of atomizing air to that of fuel (W$_{a}$ /W$_{1}$) increases, 능 decreases when fuel temperature is constant. (2) At the ratio (t/d) 4 of thickness (t) of spray nozzle hole to the diameter (d) of the hole, there is the best atomization. And SMD decreases when t/d is between 1 to 4 and increases when t/d > 4.

Influence of Atomizing Condition on Particle Size Distributions for High Pressure Water Atomized Powder

  • Nakabayashi, Koei;Tanaka, Yoshinari;Hirai, Masazumi
    • 한국분말야금학회:학술대회논문집
    • /
    • 한국분말야금학회 2006년도 Extended Abstracts of 2006 POWDER METALLURGY World Congress Part 1
    • /
    • pp.18-19
    • /
    • 2006
  • To improve the properties of fine metal powder, such as particle size distribution and geometric standard deviation, this work was done at various atomizing conditions. The new atomization mechanism and the correlation equation were proposed to estimate the mean particle diameter.

  • PDF

모멘트 방법을 이용한 전기집진기의 집진 효율 (Collection Efficiency of Electrostatic Precipitator using Moment Method)

  • 정창훈;이규원
    • 한국대기환경학회지
    • /
    • 제18권5호
    • /
    • pp.345-353
    • /
    • 2002
  • A study of polydispersed aerosol dynamics by Electrostatic Precipitator (ESP) was carried out. The log-normal particle size distribution was assumed and moment method was considered. In order to apply moment method in Deutsch-Anderson equation, Cunningham slip correction factor and Cochet's charge equation were simplified for certain range of particle size. The three parameters, which explain the particle size distribution, such as total number concentration, geometric mean diameter, and geometric standard deviation were considered to derive the analytic solution. The obtained solution was compared with available numerical results (Bai et al., 1995). The comparison of the numerical and analytic results showed a good agreement.

수정된 화학증착공정에서 에어로졸 역학, 열전달 및 물질전달 해석 (Analysis of Aerosol Dynamics, Heat and Mass Transfer in the Modified Chemical Vapor Deposition)

  • 박경순;이방원;최만수
    • 대한기계학회논문집B
    • /
    • 제23권2호
    • /
    • pp.262-271
    • /
    • 1999
  • A study of aerosol dynamics has been done to obtain axially and radially varying size distributions of particles generated in the Modified Chemical Vapor Deposition process. Heat and mass transfer have also been studied since particle generation and deposition strongly depend on the temperature field in a tube. Bimodal size distributions of particles have been obtained both in the particulate flow and in the deposited particle layer for the first time using the sectional method to solve aerosol dynamics. Variations of geometric mean diameter, geometric standard deviation have been studied for various parameters; flow rates and maximum wall temperature. The comparison between one-dimensional and two-dimensional approaches has also been made.

충진층식 세정집진기의 집진특성 실험 (An Experiment on the Particle Collection Characteristics in a Packed Wet Scrubber)

  • 유경훈;노희환;최은수;김종균
    • 설비공학논문집
    • /
    • 제15권4호
    • /
    • pp.305-311
    • /
    • 2003
  • DOP aerosol particles with geometric mean diameter of 0.5-3.0 ${\mu}{\textrm}{m}$, geometric standard deviation of 1.1-1.3 and total number concentration of 1,500-8,000 Particles/㎤ were used to determine collection efficiencies of a packed wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. Meanwhile, as for the particle size variation, all of the collection efficiency curves increased rapidly between 0.57-1.41${\mu}{\textrm}{m}$ for the range of water injection rate above 30 L/min. It was also seen that the collection efficiency of a packed wet scrubber is mainly governed by the mechanism of inertial impaction.

덕트형 세정집진기의 입자포집 특성실험 (An Experiment on Particle Collection Characteristics of a Duct-type Wet Scrubber)

  • 유경훈;여국현;손승우;황광호;정진원;김윤신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1795-1800
    • /
    • 2004
  • DOS and NaCl aerosol particles with geometric mean diameter of $0.1{\sim}3.0{\mu}m$ geometric standard deviation of $1.1{\sim}1.8$ and total number concentration of $450{\sim}400$ $particles/cm^3$ were used to determine collection efficiencies of a duct-type wet scrubber with respect to particle size. The tested operating variables included air velocity and water injection rate. It was shown from the experimental results that the collection efficiencies increased with increasing water injection rate and decreasing air velocity. It was also seen that the collection efficiency of the Duct-type wet scrubber is mainly governed by the mechanism of inertial impaction.

  • PDF

OPERATION OF TILTING 5-PADS proceeding BEARING AT DIFFERENT GEOMETRIC PARAMETERS OF PADS

  • Strzelecki, S.
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 2002년도 proceedings of the second asia international conference on tribology
    • /
    • pp.99-100
    • /
    • 2002
  • Radial, tilting-pad proceeding bearings are applied in high speed rotating machines operating at stable small and mean loads and the peripheral speeds of proceeding reaching 150 m/s. The operation of bearing can be determined by static characteristics including the oil film pressure, temperature and viscosity distributions, minimum oil film thickness, load capacity, power loss, oil flow. The operation of 5-lobe tilted-pad proceeding bearing has been introduced at the assumption of adiabatic oil film. The oil film pressure, temperature and viscosity distributions habe received by iterative solution of the Reynolds', energy and viscosity equations. The resulting oil film force, minimum oil film thickness, power loss. oil flow, maximum oil film pressure, maximum temperature were computed for different sets of bearing geometric parameters as: bearing length to diameter ratio, pad angular length and width as well as pad relative clearance.

  • PDF