• Title/Summary/Keyword: geometric standard deviation

Search Result 101, Processing Time 0.029 seconds

Particle Size of Aerosol from 0.25% Cadmium Chloride Nebulizing Solution for Inhalation Toxicology Study (흡입독성 연구에 이용될 0.25% 염화카드뮴 네뷸라이징 용액 에어로졸의 입경)

  • Jeung Jae Yeal;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.17 no.5
    • /
    • pp.1257-1263
    • /
    • 2003
  • The modified engineering methodology and the modified electronic circuit in classical ultrasonic principles were applied to ultrasonic aerosol nebulizer for inhalation toxicology study of cadmium aerosol. 1532.96ppm Cd nebulizing solution was used to generate cadmium aerosol for particle size analysis with the modifying source and inlet temperatures. The results of particle size analysis for cadmium aerosol were as following. The highest particle counting for source temperature 20℃ was 399.75 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 50℃ was 399.70 × 10² in inlet temperature 50℃ and particle diameter 0.75㎛. The highest particle counting for source temperature 70℃ was 411.14 × 10² in inlet temperature 100℃ and particle diameter 0.75㎛. The ranges of geometric mean diameter were 0.74-0.79㎛ in source temperature 20℃, 0.65-0.72㎛ in source temperature 50℃, and 0.65-0.80㎛ in source temperature 70℃. The smallest geometric mean diameter was 0.65㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest geometric mean diameter was 0.80㎛ in source temperature 70℃ and inlet temperature 100℃. The ranges of geometric standard deviation were 1.71-1.80 in source temperature 20℃, 1.27-1.61 in source temperature 50℃, and 1.27-2.29 in source temperature 70℃. The lowest geometric standard deviation was 1.27 in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the highest geometric standard deviation was 2.29 in source temperature 70℃ and inlet temperature 100℃. Generated aerosol for cadmium inhalation toxicology study was polydisperse aerosol with the above geometric standard deviation 1.2. The ranges of mass median diameter(MMD) were 1.75-2.25㎛ in source temperature 20℃, 1.27-1.61㎛ in source temperature 50℃, and 1.27-2.29㎛ in source temperature 70℃. The smallest MMD was 1.27㎛ in source temperature 50, 70℃ and inlet temperature 20, 50℃, and the largest MMD was 2.29㎛ in source temperature 70℃ and inlet temperature 100℃. Cadmium chloride concentration in nebulizing solution affected the particle size and distribution of cadium aerosol in air. MMO for inhalation toxicology testing in OECD and EU is less than 3㎛ and EPA guidance is less than 4㎛. In our results, in source temperatures of 20, 50, 70℃, and inlet temperatures of 20, 50, 100, 150, 200, 250℃ were conformed to the those guidance.

Prediction of Maximum Dry Unit Weight of Sandy Soils From Grain-Size Distribution Parameters (입도분포계수를 이용한 사질토의 최대건조단위중량 예측)

  • Song, Young-Woo;Jin, Myung-Sub;Hong, Ki-Nam
    • International Journal of Highway Engineering
    • /
    • v.6 no.3 s.21
    • /
    • pp.55-64
    • /
    • 2004
  • Maximum dry unit weight, ${\gamma}_{dmax}$, is the most important engineering properties for subgrade soil. Existing models to predict ${\gamma}_{dmax}$ containing many parameters, seem to be rather complex. This paper presents new simple models to predict ${\gamma}_{dmax}$. for sandy soils, A number of sieve analysis and compaction tests for 36 types of sands were conducted to develop the regression-based models. Parameters used to estimate ${\gamma}_{dmax}$ are both the geometric mean and geometric standard deviation of the soils, or the particle-size distribution curve parameters. Maximum dry unit weights predicted by the models are in good agreement with the laboratory measurements for the soil samples obtained at 16 locations within the Korea.

  • PDF

Development of Korean Standard Horizontal Design Spectrum Based on the Domestic and Overseas Intra-plate Earthquake Records (국내외 판내부 지진기록을 이용한 한국 표준수평설계스펙트럼의 개발)

  • Kim, Jae Kwan;Kim, Jung Han;Lee, Jin Ho;Heo, Tae Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.369-378
    • /
    • 2016
  • The design spectrum for Korea, which is known to belong to an intra-plate region, is developed from the ground motion records of the earthquakes occurred in Korea and overseas intra-plate regions. The horizontal spectrum is defined as geometric mean spectrum, GMRotI50. From the statistical analysis of the geometric mean spectra, a mean plus one standard deviation spectrum in lognormal distribution is obtained. Regression analysis is performed on this curve to determine the shape of spectrum including transition periods. The developed design spectrum is valid for the estimation both spectral acceleration and displacement.

Prediction of Hydraulic Conductivity from Gran-size Distribution Parameters (입도분포를 이용한 투수계수의 예측)

  • Song, Young-Woo;Lee, In-Koo
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.3
    • /
    • pp.5-12
    • /
    • 2002
  • Hydraulic conductivity k is one of the most important engineering properties of soil. However, both field and laboratory procedures fur the determination of k are often tedious and expensive. This paper presents new models to predict k using statistical parameters from grain size distribution. A number of permeability tests far 36 types of sands mixed based on statistics were conducted to develop the regression-based models. Parameters used to estimate k are both the geometric mean and geometric standard deviation of the soil samples, or the particle-size distribution curve parameters such as D_{10},D_{50},D_{60}. Hydraulic conductivity predicted by this model is in good agreement with the laboratory measurements fir the soil samples obtained at 20 locations within the Korean Peninsula. The performances of the proposed models were also compared with those of existing models including Hazen's.

The change of air lead concentrations in litharge making and smelting industries (일부 제련 및 리사지 사업장에서 공기중 납 노출농도의 변화)

  • Choi, Jae-Wook;Kim, Nam-Soo;Cho, Kwang-Sung;Ham, Jung-O;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.10-18
    • /
    • 2010
  • To provide necessary information for future environmental monitoring of smelting and litharge making industries in Korea, environmental monitoring dataset of air lead concentration of 4 lead industries(1 primary smelting, 2 secondary smelting and 1 litharge making industry) were analyzed from 1994 to 2007. Data were compared using geometric mean and standard deviation with minimum and maximum values according to year of measurement, type of lead industries and type of operation of lead industries. The geometric mean and standard deviation of air concentration for a total of 1140 samples in all lead industries for overall 14 years were 70.7${\mu}g/m^3$ and 5.51 with minimum of 1${\mu}g/m^3$ and maximum of 9,185 ${\mu}g/m^3$. The overall geometric means of air concentration were above the permissible exposure levels(PEL) until year of 2001 and thereafter they were remained at the level of half of PEL. The geometric means of primary smelting, secondary smelting and litharge making industry for overall 14 years were 21.7${\mu}g/m^3$(number of samples: 353), 82.5${\mu}g/m^3$(number of samples: 357) and 164.2 ${\mu}g/m^3$(number of samples: 430) respectively. In primary smelting industry, the highest geometric mean air concentration was 35.4 ${\mu}g/m^3$ in the secondary smelting operation; followed by casting operation (24.9 ${\mu}g/m^3$) and melting operation (14.9 ${\mu}g/m^3$), respectively. On the other hand, in secondary smelting industries, the highest geometric mean air concentration was 125.4${\mu}g/m^3$ in melting operation; followed by casting operation (90.5${\mu}g/m^3$) and pre-treatment operation (43.4${\mu}g/m^3$), respectively. However, in litharge making industries, there were no significant differences of geometric mean air concentrations between litharge operation and stabilizer operation. The proportion of over PEL (50${\mu}g/m^3$) was highest in litharge industry and followed by secondary smelting industries. However The proportions of over PEL(${\mu}g./m^3.$) were decreased by the years of environmental monitoring. The significant reduction of mean air lead concentration since year of 2000 was observed due to more active environmental engineering control and new introduction of new operation in manufacturing process, but may be also influenced by non-engineering method such as reduction of operation hours or reduction of exposure time during actual environmental measurement by industrial hygienist according to more strict enforcement of occupational and safety law by the government.

Response Spectra of 2016 Gyeongju Earthquake and Comparison with Korean Standard Design Spectra (2016년 경주지진 스펙트럼과 한국표준설계스펙트럼의 비교)

  • Kim, Jae Kwan;Kim, Jung Han;Lee, Jin Ho;Heo, Tae Min
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.6
    • /
    • pp.277-286
    • /
    • 2017
  • On September 12, 2016, Gyeongju earthquake occurred. Its local magnitude was announced to be $M_L=5.8$ by Korea Meteorological Administration (KMA). Ground motion data recorded at KMA, EMC and KERC stations was obtained from their data bases. From the data, horizontal and vertical response spectra, and V/H ratio were calculated. The horizontal spectrum was defined as geometric mean spectrum, GMRotI50. From the statistical analysis of the geometric mean spectra, a mean plus one standard deviation spectrum in lognormal distribution is obtained. Regression analysis is performed on this curve to determine the shape of spectrum including transition periods. Applying the same procedure, the shape and transition periods of vertical spectrum was obtained. These results were compared with the Korean standard design spectra, which were developed from domestic and overseas intraplate earthquake records. The response spectra of Gyeongju earthquake were found to be almost identical with the newly proposed design spectra. Even the V/H ratios showed good agreement. These results confirmed that the method adopted when developing the standard design spectra were valid and the developed design spectra were reliable.

Adjustment of Control Limits for Geometric Charts

  • Kim, Byung Jun;Lee, Jaeheon
    • Communications for Statistical Applications and Methods
    • /
    • v.22 no.5
    • /
    • pp.519-530
    • /
    • 2015
  • The geometric chart has proven more effective than Shewhart p or np charts to monitor the proportion nonconforming in high-quality processes. Implementing a geometric chart commonly requires the assumption that the in-control proportion nonconforming is known or accurately estimated. However, accurate parameter estimation is very difficult and may require a larger sample size than that available in practice in high-quality process where the proportion of nonconforming items is very small. Thus, the error in the parameter estimation increases and may lead to deterioration in the performance of the control chart if a sample size is inadequate. We suggest adjusting the control limits in order to improve the performance when a sample size is insufficient to estimate the parameter. We propose a linear function for the adjustment constant, which is a function of the sample size, the number of nonconforming items in a sample, and the false alarm rate. We also compare the performance of the geometric charts without and with adjustment using the expected value of the average run length (ARL) and the standard deviation of the ARL (SDARL).

Influence of Atomizing Condition on Particle Size Distributions for High Pressure Water Atomized Powder

  • Nakabayashi, Koei;Tanaka, Yoshinari;Hirai, Masazumi
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.18-19
    • /
    • 2006
  • To improve the properties of fine metal powder, such as particle size distribution and geometric standard deviation, this work was done at various atomizing conditions. The new atomization mechanism and the correlation equation were proposed to estimate the mean particle diameter.

  • PDF

상압 분위기에서 QD 제작 및 이를 응용한 비휘발성 QD 메모리 특성 평가

  • 안강호;안진홍;정혁
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2005.09a
    • /
    • pp.137-141
    • /
    • 2005
  • Quantum dot(QD) 메모리용 silicon nano-particle을 corona 방전방법에 의해 상온에서 대량 발생하는 방법을 개발하였다. Silicon QD는 SiH4 가스를 코로나 방전 영역을 통과시켜 발생시켰으며, 코로나 전압은 2.75kV를 사용하였다. SiH4 몰농도 $0.33{\times}10^{-7}\;mol/l$ 일 경우 발생된 QD입자 크기는 약 10nm이며 기하학적 표준편차(geometric standard deviation)는 1.31이었다. 이 조건에서 nonvolatile quantum dot semiconductor memory (NVQDM)를 제작하였으며, 이렇게 제작된 NVQDM flat band voltage는 1.5 volt였다.

  • PDF

Analysis of Gravitational Coagulation of Aerosol Particles (중력 침강에 의한 입자 응집의 해석적 연구)

  • Jin, Hyeong-A;Jeong, Chang-Hun;Lee, Gyu-Won
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.14 no.4
    • /
    • pp.303-312
    • /
    • 1998
  • To obtain the solution to the time-dependent particle size distribution of an aerosol undergoing gravitational coagulation, the moment method was used which converts the non linear integro-differential equation to a set of ordinary differential equations. A semi-numerical solution was obtained using this method. Subsequently, an analytic solution was given by approximating the collision kernel into a form suitable for the analysis. The results show that during gravitational coagulation, the geometric standard deviation increases and the geometric mean radius decreases as time increases.

  • PDF