• 제목/요약/키워드: inyoung pulse

검색결과 13건 처리시간 0.023초

정상인에게서 측정되는 인영촌구맥의 경향성 분석 (Analysis of Inyoung-Chongu Pulse Measured on Normal People)

  • 최찬헌
    • 동의생리병리학회지
    • /
    • 제24권1호
    • /
    • pp.158-164
    • /
    • 2010
  • The aim of this study is to examine the reliability of Inyoung-Chongu pulse diagnosis by analyzing Inyoung-Chongu pulse measured on normal people. I measure the size of Inyoung & Chongu pulse, ratio of Inyoung to Chongu, and ratio of Chongu to Inyoung on 50 normal people. Inyoung pulse of normal people is $6.44{\pm}1.62$ volt and Chongu pulse of normal people is $6.81{\pm}1.70$ volt. The ratio of Inyoun to Chongu is $1.03{\pm}0.50$ and that of Chongu to Inyoung is $1.12{\pm}0.41$. Through this experiment, I conclude that the Inyoung-Chongu pulse diagnosis is reproducible on normal people and can develop pulse diagnosis device through comparison between Inyoung and Chongu pulse.

기구인영맥(氣口人迎脈)에 관한 연구 (A study on Gigoo-inyoung pulse)

  • 석진한;심철웅;최현배;이시형
    • 대한한의정보학회지
    • /
    • 제18권1호
    • /
    • pp.78-115
    • /
    • 2012
  • Pulse diagnosis has been highly valued in many East Asian medical books, since "Huangdaineijing(黃帝內經)" published. Gigoo-inyoung pulse method(氣口人迎脈法) is one of the four pulse diagnostic methods originally written in"Huangdaineijing(黃帝內經)". At the late 3rd century, "Maijing(脈經)" redefined the positions of Gigoo-inyoung pulse(氣口人迎脈). According to "Maijing(脈經)", both spots were 1fen(分) in front of guan(關) but Gigoo on the right hand and Inyoung on the left hand. At the middle of 13th century, "Maekgyolejijangbyungsikdoseol(脈訣指掌病式圖說)" had detailed view points about the manner of reading Gigoo-inyoung pulse. "Maekgyolejijangbyungsikdoseol(脈訣指掌病式圖說)" explained clearly the position of 1fen(分) in front of guan(關) by sketch of wrist. The location indicated the border of cun(寸) and guan(關). It also explained clearly corresponding certain cun-guan-chi(寸關尺) with Gigoo-inyoung pulse by sketch. "Euihackipmoon(醫學入門)" is a comprehensive book on medicine written by Lee-Cheon(李梴) in Ming(明) dynasty. In this book, pulse diagnosis is the most emphasized method among the four techniques of diagnosis(四診). Furthermore, it introduces detailed information about Gigoo-inyoung pulse method(氣口人迎脈法) in "Gigoo-inyoungmaekgyole(氣口人迎脈訣)". Lee-Cheon concured in the theory of "Yeongruegumbang(永類鈐方)" and "Maekgyolejijangbyungsikdoseol(脈訣指掌病式圖說)" and put a short essay about Gigoo-inyoung pulse named "Gigoo-inyoungmaekgyole(氣口人迎脈訣)" quoted from the two books. Therefore, throughout many chapters of "Euihackipmoon(醫學入門)", Gigoo-inyoung pulse is used in order to distinguish internal damage(內傷) and external contraction(外感). "Maekgyolejijangbyungsikdoseol(脈訣指掌病式圖說)" and "Euihackipmoon(醫學入門)" understood Gigoo-inyoung pulse commonly by corresponding certain cun-guan-chi(寸關尺) with Gigoo-inyoung pulse. Therefrom, Gigoo-inyoung pulse can distinguish seven emotions(七情) of internal damage(內傷) or six excesses(六淫) of external contraction(外感).

  • PDF

초음파와 맥진기로 살펴본 인영맥의 세기와 경동맥의 상관 요인 연구 (Association of the Strength of Inyoung Pulse and Carotid Artery Using Ultrasonography and Pulse Diagnosis Device)

  • 송민선;이상영;최찬헌
    • 동의생리병리학회지
    • /
    • 제26권5호
    • /
    • pp.610-614
    • /
    • 2012
  • This study was done to identify correlates of carotid artery ultrasonography's measurement and Inyoung pulse in college students. We measured the amplitude of Inyoung pulse, Chongu pulse, ratio of Inyoung to Chongu and ratio of Chongu to Inyoung on 30 college students. Also, We measured the Distance, Diameter), RI(resistivity index), S/D(systolic, diastolic ratio), PI(pulsatility index), PSV(peak systolic velocity), EDV(End diastolic velocity), Vmean using carotid artery ultrasonography. The data was analyzed by Pearson's correlation coefficient using SAS program. The results were as follow. Results showed a positive correlation between Inyoung pulse and diameter by carotid artery. It showed a positive correlation between Inyoung pulse and S/D. Also, It showed a positive correlation between Inyoung pulse and PSV. As a result, the strength of Inyoung pulse related with the diameter of carotid artery and blood flow velocity.

맥진기를 이용한 인영촌구맥과 체질량지수 및 사상체질간의 관계연구 (Relationship of Inyoung-Chongu Pulse, BMI and Sasang Constitution Using Pulse Diagnosis Device)

  • 송민선;박혜선;김오영;김병수;양동혁;최찬헌
    • 동의생리병리학회지
    • /
    • 제25권2호
    • /
    • pp.339-344
    • /
    • 2011
  • The purpose of this study was to evaluate the relationship of Inyoung-Chongu pulse, body mass index (BMI) and Sasang constitution using pulse diagnosis device in college women. We measured the amplitude of Inyoung pulse, Chongu pulse, ratio of Inyoung to Chongu and ratio of Chongu to Inyoung on 69 college women. The data was analyzed by ANOVA and Pearson's correlation coefficient using SAS program. The results were as follow. There was no significant difference in Inyoung pulse, Chongu pulse, Inyoung to Chongu ratio and Chongu to Inyoung ratio according to BMI and Sasang constitution. There was significant difference in BMI among Sasang constitution. BMI was significantly high in Taeeumin than in Soyangin and Soeumin. We concluded that there was no relation among Inyoung-Chongu pulse, BMI and Sasang constitution. Therefore, we need to expand the sample size for in depth study.

기구인영비교맥법에 대한 수지맥진과 기기측정치의 상관성 연구 (Study of the relationship between manual pulse diagnosis and machinery measurement on QiguㆍInyoung comparison pulse diagnosis)

  • 전용석;채우석;조명래;소철호;최찬헌;장경선
    • 동의생리병리학회지
    • /
    • 제16권1호
    • /
    • pp.201-208
    • /
    • 2002
  • The measurement parameter of QiguㆍInyoung pulse diagnosis distinguishes the excess, deficiency and quick-temper of pulse through relative comparison of Qigu and Inyoung. We have estimated the relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis by means of quantifying pulse peak and Inyoung/Qigu index. The results can be summarized as follows : When standardizing manual pulse diagnosis measurement was standardized, Inyoung index of machinery measurement was more significantly correlative with the index of manual pulse diagnosis than Qigu index of machinery measurement. The ratio of Inyoung/Qigu magnitude with machinery measurement was doser to manual pulse diagnosis than that of Qigu and Inyoung pulse magnitude measured separately. A linear proportion relationship was found between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis. It was necessary to adjust the output signal of pulse in order to estimate the exact relationship between measurement of QiguㆍInyoung pulse wave detection system and measurement of manual pulse diagnosis.

인영.촌구 대비법을 이용한 맥 진단 시스템 구현 (Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method)

  • 이호재;박영배;허웅
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

혈류역학을 이용한 촌구와 인영의 특성비교 (Comparative study of pulse point using hemodynamics)

  • 신상훈;박대훈;박영재;박영배
    • Journal of Acupuncture Research
    • /
    • 제21권5호
    • /
    • pp.241-248
    • /
    • 2004
  • Objectives : The purpose of this study is to examine the hemodynamic characteristics of pulse point. Methods : The computational analysis algorithms of arterial tree system was derived. In order to investigate the effect of internal organ on the pulse point, the diameter of celiac artery was reduced by half. Results : The sensitivity of flow change at the Inyoung(Renying) is better than that of the Chongu(Cunkou). but the Inyoung was worse than the Chongu in the point of the left and right symmetry. The pressure changes at the Inyoung and the Chongu were in the similar range. Conclusions : It was found from the result that the Chongu shows the more symmetrical hemodynamic characteristics than the Inyoung.

  • PDF

Immobilization of Heparin onto the Polyurethane

  • Cho, Chong-Su;Kim, Sung-Wan
    • 대한의용생체공학회:의공학회지
    • /
    • 제7권2호
    • /
    • pp.147-150
    • /
    • 1986
  • This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine.

  • PDF

침 처방용 진단 시스템 (A Diagnosis System for the Acupuncture Prescription)

  • 김진우;이호재;김홍오;허웅
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1992년도 춘계학술대회
    • /
    • pp.75-78
    • /
    • 1992
  • This paper describes research about the realization of a diagnosis system for the surgical operation of the acupuncture. The system consists of the Munjin, Bokjin and Makjin software. The Munjin system diagnoses the pain spots or each Kyoungnats of the hands, root and neck. The Bokjin system diagnoses pressure-pain spots of the twelve Kyoungnak at chest and abdomen by following the displayed positions on the monitor in sequentially. The Maekjin system diagnoses radial pulse or inyoung and chongu according to the Inyoung-Chongu comparison in ethod. Compound diagnosis verifies the results which obtained from each diagnosis routine by the interface rule. This developed system contains the database which for the paitents diagnosis and treatment process recoding.

  • PDF

《영추(靈樞)·경맥(經脈)》의 촌구인영맥진(寸口人迎脈診)에 관(關)한 연구(硏究) (A study on diagnosis method by chonguinyoung pulse(寸口人迎脈診) based on 《Youngchu·Kyoungmaek 靈樞·經脈》)

  • 신광순;장준혁;윤종화
    • Journal of Acupuncture Research
    • /
    • 제19권1호
    • /
    • pp.203-209
    • /
    • 2002
  • Objective : The chonguinyoung pulse diagnosis method is convenient than twelve meridian pulse diagnosis method The $\ll$Maek-bup(脉法)$\gg$ are founded at Mawangtweo(馬王堆) of the han dynasty tomb in 1973, but it could diagnosis the exsitance of illness of twelve meridian also . Methods : In accordance to $\ll$Naekuoung(內經)$\gg$ inyoungmaek(人迎脈) in could be taken at the which is the pulse point of carotid artery on the line of foot yangmyoung stomach meridian (足陽明胃經) and chongumaek (寸口脈) at the taeyoun acu-point (太淵穴) pulse point on the line of hand taeyeun lung meridian (手太陰肺經). Results : Chonguinyoung pulse diagnosis method could be emphased on the point of diagnosing sick person and healthy person by the balance of yin (陰) yan (陽) composition in the body. Conclusion : Chonguinyoung pulse diagnosis method could be the indication of improvement and progress of disease also it could be adapt to diagnosis of twelve meridian and it is impossible to making choice of acupuncture, medication, moxibustion, vene-section and strengthing-eleminating treatment method (補瀉方法).

  • PDF