• Title/Summary/Keyword: light-scattering photometer

Search Result 5, Processing Time 0.022 seconds

Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air (대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정)

  • Kim, Jong Bum;Kim, Danbi;Noh, Sujin;Yoon, Kwan Hoon;Park, Duckshin;Lee, Jeong Joo;Kim, Jeongho
    • Particle and aerosol research
    • /
    • v.16 no.2
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Depolarization Ratio Retrievals Using AERONET Sun Photometer Data

  • Lee, Kyung-Hwa;Muller, Detlef;Noh, Young-Min;Shin, Sung-Kyun;Shin, Dong-Ho
    • Journal of the Optical Society of Korea
    • /
    • v.14 no.3
    • /
    • pp.178-184
    • /
    • 2010
  • We present linear particle depolarization ratios (LPDRs) retrieved from measurements with an AERONET Sun photometer at the Gwangju Institute of Science and Technology (GIST), Korea ($35.10^{/circ}N$, $126.53^{\circ}E$) between 19 October and 3 November 2009. The Sun photometer data were classified into three categories according to ${\AA}$ngstr$\ddot{o}$ exponent and size distribution: 1) pure Asian dust (19 October 2009), 2) Asian dust mixed with urban pollution observed in the period from 20-26 October 2009, and 3) clean conditions (3 November). We show that the LPDRs can be used to distinguish among Asian dust, mixed aerosol, and non-Asian dust in the atmosphere. The mean LPDR of the pure Asian dust case is 23 %. Mean LPDRs are 13 % for the mixed case. The lowest mean LPDR is 6 % in the clean case. We compare our results to vertically resolved LPDRs (at 532 nm) measured by a Raman LIDAR system at the same site. In most cases, we find good agreement between LPDRs derived with Sun photometer and measured by LIDAR.

PRODUCT10N OF KSR-III AIRGLOW PHOTOMETERS TO MEASURE MUV AIRGLOWS OF THE UPPER ATMOSPHERE ABOVE THE KOREAN PENINSULAR (한반도 상공의 고층대기 중간 자외선 대기광 측정을 위한 KSR-III 대기광도계 제작)

  • Oh, T.H.;Park, K.C.;Kim, Y.H.;Yi, Y.;Kim, J.
    • Journal of Astronomy and Space Sciences
    • /
    • v.19 no.4
    • /
    • pp.305-318
    • /
    • 2002
  • We have constructed two flight models of airglow photometer system (AGP) to be onboard Korea Sounding Rocket-III (KSR-III) for detection of MUV dayglow above the Korean peninsular. The AGP system is designed to detect dayglow emissions of OI 2972${\AA}$, $N_2$ VK(0,6) 2780${\AA}$, $N_2$ 2PG 3150${\AA}$ and background 3070${\AA}$ toward the horizon at altitudes between 100 km and 300 km. The AGP system consists of a photometer body, a baffle an electronic control unit and a battery unit. The MUV dayglow emissions enter through a narrow band interference filter and focusing lens of the photometer, which contains an ultraviolet sensitive photomultiplier tube. The photometer is equipped with an in-flight calibration light source on a circular plane that will rotate at the rocket's apogee. A bane tube is installed at the entry of the photometer in order to block strong scattering lights from the lower atmosphere. We have carried out laboratory measurements of sensitivity and in-flight calibration light source for the AGP flight models. Although absolute sensitivities of the AGP flight models could not be determined in the country, relative sensitivities among channels are well measured so that observation data during rocket flight in the future can be analyzed with confidence.

Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer (공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가)

  • Jeung Jae Yeal;Milton Donald K.;Kim Tae Hyeung;Lee Jong Young;Chong Myoung Soo;Ko Kwang Jae;Kim Sang Duck;Kang Sung Ho;Song Young Sun;Lee Ki Nam
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.16 no.3
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.

Preparation and Characterization of Cy5.5-conjugated Biocompatible Polymeric Micellar Nanoparticles for Optical Imaging (광학 영상을 위한 Cy5.5가 결합된 생체적합성 고분자 마이셀 나노입자의 제조 및 특성분석)

  • Kim, Hyo-Jeong;Kim, Byung-Jin;Lee, Ha-Yeong;Jung, Suk Hyun;Jeong, Seo-Young;Yuk, Soon-Hong;Shin, Byung-Cheo;Seong, Ha-Soo;Choi, Youn-Woong;Ha, Dae-Chul;Choi, Sun-Hang;Lee, Soo-Min
    • Journal of Pharmaceutical Investigation
    • /
    • v.39 no.6
    • /
    • pp.393-400
    • /
    • 2009
  • PHEA (hydroxyethyl-aspartamide)-mPEG (methoy-polyethyleneglycol)-$C_{16}$ (hexadecylamine)-ED (ethylenediamine) was prepared as a drug delivery carrier. The structure and molecular weight of polymers were characterized by $^1H$-NMR and gel permeation chromatography. Micelle size and shape were measured by electro-photometer light scattering and transmission electron microscope. The mean diameter of micelles was 23 nm in aqueous solution. To evaluate the potential of these polymeric micelles as a drug carrier, PSI-mPEG-$C_{16}$-ED was conjugated with Cy5.5 for Near-Infrared Fluorescent (NIRF) based optical imaging. PSI-mPEG-$C_{16}$-ED-Cy5.5 was injected intravenously into mice (n=5) and in vivo NIRF imaging was performed during 48 h after injection. The biodistribution study at 24 h after injection showed the longcirculation property of PSI-mPEG-$C_{16}$-ED-Cy5.5. Therefore, PSI-mPEG-$C_{16}$-ED micelles could be a promising drug carrier and imaging agent.