• 제목/요약/키워드: light-scattering photometer

검색결과 5건 처리시간 0.022초

대기환경에서 광산란 미세먼지 측정기의 PM2.5 보정계수 산정 (Estimation of PM2.5 Correction Factor for Optical Particle Counter in Ambient Air)

  • 김종범;김단비;노수진;윤관훈;박덕신;이정주;김정호
    • 한국입자에어로졸학회지
    • /
    • 제16권2호
    • /
    • pp.49-59
    • /
    • 2020
  • Various devices have been developed to the measurement of particulate matter pollutants, and Optical Particle Counter (OPC) that can be easily and quickly measured is widely used lately. The measured value by OPC is converted to weight concentration using the correction factor (CF). The calculation of CF is very important to improve the reliability and accuracy of OPC. In this study, the CF calculation study of light scattering laser photometer (model 8533, TSI) was carried out to measure in the atmospheric environment using 2 gravimetric devices and 3 light scattering laser photometer devices. Regression analysis and Tukey tests were used to significance the test of measurement devices. Measurements were carried out twice. There was a comparative analysis of measurement data between light scattering laser photometer and gravimetric devices in 1st measurement, and then the Evaluation of PM2.5 concentration corrected by CF performed in 2nd measurement. As a result of the significance analysis between light scattering laser photometer and gravimetric devices, the correlation between the same method was high, but the correlation between different methods was low. CF was calculated as 0.4258 based on the measurement results, and it is a similar level to previous studies at home and abroad. It is expected that these results can be used as basic data in the future study for air quality measurement research using light scattering laser photometer. Also, in order to improve the accuracy of the measurement techniques and the development of technology in the atmospheric environment, CF calculation research should be conducted continuously.

Depolarization Ratio Retrievals Using AERONET Sun Photometer Data

  • Lee, Kyung-Hwa;Muller, Detlef;Noh, Young-Min;Shin, Sung-Kyun;Shin, Dong-Ho
    • Journal of the Optical Society of Korea
    • /
    • 제14권3호
    • /
    • pp.178-184
    • /
    • 2010
  • We present linear particle depolarization ratios (LPDRs) retrieved from measurements with an AERONET Sun photometer at the Gwangju Institute of Science and Technology (GIST), Korea ($35.10^{/circ}N$, $126.53^{\circ}E$) between 19 October and 3 November 2009. The Sun photometer data were classified into three categories according to ${\AA}$ngstr$\ddot{o}$ exponent and size distribution: 1) pure Asian dust (19 October 2009), 2) Asian dust mixed with urban pollution observed in the period from 20-26 October 2009, and 3) clean conditions (3 November). We show that the LPDRs can be used to distinguish among Asian dust, mixed aerosol, and non-Asian dust in the atmosphere. The mean LPDR of the pure Asian dust case is 23 %. Mean LPDRs are 13 % for the mixed case. The lowest mean LPDR is 6 % in the clean case. We compare our results to vertically resolved LPDRs (at 532 nm) measured by a Raman LIDAR system at the same site. In most cases, we find good agreement between LPDRs derived with Sun photometer and measured by LIDAR.

한반도 상공의 고층대기 중간 자외선 대기광 측정을 위한 KSR-III 대기광도계 제작 (PRODUCT10N OF KSR-III AIRGLOW PHOTOMETERS TO MEASURE MUV AIRGLOWS OF THE UPPER ATMOSPHERE ABOVE THE KOREAN PENINSULAR)

  • 오태형;박경춘;김용하;이유;김준
    • Journal of Astronomy and Space Sciences
    • /
    • 제19권4호
    • /
    • pp.305-318
    • /
    • 2002
  • 한반도 상공의 중간 자외선 대기광을 측정하기 위해 3단형 과학로켓(KSR-III)에 탑재될 대기광도계(Airglow Photometer, AGP)가 제작되었다. 대기광도계 비행 모형(FM)은 4-channel로 이루어져 100km~300km 구간의 중간 자외선 영역의 OI 2972${\AA}$, $N_2$ VK(0,6) 2780${\AA}$, $N_2$ 2PG 3150${\AA}$ 대기광과 배경으로 3070${\AA}$을 지평선 방향으로 측정하게 된다. 대기광도계는 광도계 본체, 차폐경(Baffle), 전자제어부, 전원공급기로 구성되어 있다. 광도계 본체는 협대역 간섭 필터를 통해 선택된 파장의 대기광을 직경 2.5cm 렌즈로 초점면에 설치된 실틈(slit)을 통해 자외선 감지용 광전증배관으로 진입시키는 구조로 되어있다. 비행중 영점 측정을 위해 초점면 실틈 뒤편의 회전판에 영점광원을 설치하였다. 차폐경은 저충대기로부터 산란되는 태양광이 광도계로 진입하지 못하도록 성능을 최적화하여 설계 제작되었다. 대기광도계 비행모형의 지상 테스트로서 각광도계의 성능 테스트 및 감응도, 영점 측정 등을 실시하였다. 대기광도개가 미약한 빛을 감응하도록 제작되었기 때문에 국내에서 신뢰도를 갖고 절대 감응도를 결정할 수 없었다. 그러나 대기광도계 각 channel 간 상대 감응도 측정값은 안정되게 측정되었기 때문에, 추후 로켓 비행시 측정한 자료를 신뢰성있게 분석할 수 있을 것으로 기대된다.

공학적 기법을 응용한 카드뮴의 흡입독성 연구를 위한 초음파 네뷸라이져의 설계 그리고 광산란 광도계를 이용한 성능평가 (Design of Ultrasonic Nebulizer for Inhalation Toxicology Study of Cadmium with Application of Engineering Methodology and Performance Evaluation with Light-Scattering Photometer)

  • 정재열;도날드밀턴;김태형;이종영;정명수;고광재;김상덕;강성호;송용선;이기남
    • 동의생리병리학회지
    • /
    • 제16권3호
    • /
    • pp.464-471
    • /
    • 2002
  • Author applied several engineering methodologies to classical ultrasonic nebulizer to cope with it's demerits. After several trials and errors, we got the several meaningful results. To evaluate the modified ultrasonic nebulizer for inhalation toxicology of cadmium, author used light-scattering photometer. This paper is the one part of inhalation exposure systems for inhalation toxicology study of cadmium. According to the testing conditions, source temperature 50℃ and inlet-duct band temperature 150℃, aerosol generation results for sodium chloride and cadmium chloride were as followings: Coefficients of variation(CV) of sodium chloride and cadmium chloride for repeated trials were 3.38 and 4.77 for 10g, 2.47 and 5.02 for 5g, and 4.70 and 2.98 for 2.5g. All the CVs were within 10% of acceptance variability. Count Per Minute(CPM) changes of NaCl and CdCl₂ for 5 repeated trials were similar. CPM ratios of CdCl₂/NaCl were 1.13 for 10g, 0.76 for 5g, and 1.06 for 2.5g. Relative aerosol generation of cadmium chloride to sodium chloride was the highest in 10g. Efficiency increases of 24.50% for 5g NaCl, 14.91 % for 2.5g NaCl, and 16.48% for 2.5g CdCl₂ with respect to theoretical efficiency were observed but 0.04% efficiency decrease was observed in 5g CdC₂. According to the modifications of source temperature(20, 50, 70℃) and inlet-duct band temperature(20, 50, 100, 150, 200℃), aerosol generation results for NaCl and CdCl₂ were as followings: CPM trends for each quantity excepting 10g NaCl in inlet-duct band temperature 200℃ were similar, and the highest CPM was observed in source temperature 70℃ to each inlet-duct band temperature. The highest CPMs to 10, 5, and 2.5g NaCl were observed in source temperature 70℃ and inlet-duct band temperature 20℃. Aerosol generation of cadmium chloride was increased with the higher source temperature, excepting inlet-duct band temperature 200℃. The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this trend was similar to NaCl aerosol generation The highest CPMs for 10, 5, and 2.5g CdCl₂ were observed in source temperature 70℃ and inlet-duct band temperature 20℃, and this result was similar to NaCl aerosol generation. Observed efficiencies of 5 and 2.5g NaCl were similar to ifs theoretical efficiency but -3.08% efficiency decrease of 5g CdCl₂, 17.47% efficiency increase of 2.5g CdCl₂ were observed. CPM ratio of CdCl₂/NaCl of 10g was different to 5 and 2.5g, and 2.5g ratio was higher than 5g ratio. In conclusion, to get maximum aerosol generation for NaCl and CdCl₂ will be the conditions that set the appropriate inlet-duct band temperature for each materials and increase the source temperature. Sodium chloride can be used to evaluate the performance and predict the concentration for cadmium aerosol in aerosol generator and inhalation exposure system.

광학 영상을 위한 Cy5.5가 결합된 생체적합성 고분자 마이셀 나노입자의 제조 및 특성분석 (Preparation and Characterization of Cy5.5-conjugated Biocompatible Polymeric Micellar Nanoparticles for Optical Imaging)

  • 김효정;김병진;이하영;정석현;정서영;육순홍;신병철;성하수;최연웅;하대철;조선행;이수민
    • Journal of Pharmaceutical Investigation
    • /
    • 제39권6호
    • /
    • pp.393-400
    • /
    • 2009
  • PHEA (hydroxyethyl-aspartamide)-mPEG (methoy-polyethyleneglycol)-$C_{16}$ (hexadecylamine)-ED (ethylenediamine) was prepared as a drug delivery carrier. The structure and molecular weight of polymers were characterized by $^1H$-NMR and gel permeation chromatography. Micelle size and shape were measured by electro-photometer light scattering and transmission electron microscope. The mean diameter of micelles was 23 nm in aqueous solution. To evaluate the potential of these polymeric micelles as a drug carrier, PSI-mPEG-$C_{16}$-ED was conjugated with Cy5.5 for Near-Infrared Fluorescent (NIRF) based optical imaging. PSI-mPEG-$C_{16}$-ED-Cy5.5 was injected intravenously into mice (n=5) and in vivo NIRF imaging was performed during 48 h after injection. The biodistribution study at 24 h after injection showed the longcirculation property of PSI-mPEG-$C_{16}$-ED-Cy5.5. Therefore, PSI-mPEG-$C_{16}$-ED micelles could be a promising drug carrier and imaging agent.