• Title/Summary/Keyword: pCR

Search Result 1,850, Processing Time 0.033 seconds

Magnetic Properties of Co-P and Co-P-Cr Thin Films for Longitudinal Magnetic Recording (수평자기기록용 Co-P, Co-P-Cr 박막의 자기적특성)

  • Pyun-Woo Jang;Hong-Kyun Sohn;Taek-Dong Lee
    • Journal of the Korean Magnetics Society
    • /
    • v.4 no.2
    • /
    • pp.160-167
    • /
    • 1994
  • In order to develop new magnetic media with higher coercivity, we have investigated the magnetic properties of Co-P/Cr and Co-P-Cr/Cr films. The coercivity of Co-P binary films deposited at RT was around 835 Oe in the range of 9-12 at.% P. In the Co-P binary system coercivity decreased with increasing substrate temperature for P contents of 9-12 at.%, which may be due to the decomposition of Co-P single phase to Co and $Co_{2}P$ phase. However, the coercivity of the films containing more than 12 at.% P is very low due to the formation of amorphous phase. The coercivity of Co-P-Cr ternary films increased with increasing Cr contents and reached the maximum value of 1020 Oe in the water $Co_{84}P_{10}Cr_{6}$ Film.

  • PDF

Electro-deposition and Crystallization Behaviors of Cr-C and Cr-C-P Alloy Deposits Prepared by Trivalent Chromium Sulfate Bath (황화물계 3가 크롬도금욕에서 크롬-탄소 및 크롬-탄소-인 합금도금의 전착과 결정화거동)

  • Kim, Man;Kim, Dae-Young;Park, Sang-Eon;Kwon, Sik-Chul;Choi, Yong
    • Journal of the Korean institute of surface engineering
    • /
    • v.37 no.2
    • /
    • pp.80-85
    • /
    • 2004
  • Chromium-carbon (Cr-C) and chromium-carbon-phosphorus (Cr-C-P) alloy deposits using trivalent chromium sulfate baths containing potassium formate were prepared to study their current efficiency, hardness change and phase transformations behavior with heat treatment, respectively. The current efficiencies of Cr-C and Cr-C-P alloy deposits increase with increasing current density in the range of 15-35 A/dm$^2$. Carbon content of Cr-C and phosphorous of Cr-C-P layers decreases with increasing current density, whereas, the carbon content of Cr-C-P layer is almost constant with the current density. Cr-C deposit shows crystallization at $400^{\circ}C$ and has (Cr+Cr$_{ 23}$$C_{6}$) phases at $800^{\circ}C$. Cr-C-P deposit shows crystallization at $600^{\circ}C$ and has (Cr+Cr$_{23}$ $C_{6}$$+Cr_3$P) phases at $800^{\circ}C$. The hardness of Cr-C and Cr-C-P deposits after heating treatment for one hour increase up to Hv 1640 and Hv 1540 and decrease about Hv 820 and Hv 1270 with increasing annealing temperature in the range of $400~^{\circ}C$, respectively. The hardness change with annealing is due to the order of occurring of chromium crystallization, precipitation hardening effect, softening and grain growth with temperature. Less decrease of hardness of Cr-C-P deposit after annealing above $700^{\circ}C$ is related to continuous precipitation of $Cr_{23}$ $C_{6}$ and $Cr_3$P phases which retard grain growth at the temperature.

First-principles Study on the Half-metallicity and Magnetism of the (001) Surfaces of (AlP)1/(CrP)1 Superlattice ((AlP)1/(CrP)1 초격자계에서 (001) 표면의 자성과 반쪽금속성에 대한 제일원리 연구)

  • Bialek, Beata;Lee, Jae Il
    • Journal of the Korean Magnetics Society
    • /
    • v.25 no.6
    • /
    • pp.175-179
    • /
    • 2015
  • The half-metallicity and magnetism of the (001) surfaces of $(AlP)_1/(CrP)_1$ superlattice were investigated by means of FLAPW (Full-potential Liniarized Augmented Plane Wave) method. We considered four types of (001) surface termination, i.e., Al(S)-, Cr(S)-, P(S)Al(S-1)- and P(S)Cr(S-1)-term systems. We found that only Cr(S)-term system maintains the half-metallicity at the surface as only this system has the calculated magnetic moment of integer number of bohr magnetons. The magnetic moment of Cr(S) atom in the system was $3.02{\mu}_B$ which was increased from the bulk value by the effects of band narrowing and increased spin-splitting at the surface. The electronic density of states of the P(S) atom in the P(S)Al(S-1)-term showed very sharp surface states due to the broken $p_z$ bonds at the surface. We found there is still a strong p-d hybridization between the P(S) and Cr(S-1) layers in the P(S)Cr(S-1)-term which causes a considerable increase of magnetic moment of P(S) atom.

Effects of Different Sources of Dietary Chromium on Growth, Blood Profiles and Carcass Traits in Growing-finishing Pigs

  • Park, J.K.;Lee, J.Y.;Chae, B.J.;Ohh, S.J.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.11
    • /
    • pp.1547-1554
    • /
    • 2009
  • This study was carried out to evaluate the effects of dietary supplementation of different sources of chromium on growth performance, blood profile and carcass trait in growing-finishing pigs. A total of 200 growing pigs (Landrace${\times}$Yorkshire)${\times}$Duroc, average initial weight 8.5 kg) were allotted to 5 treatments with 4 replicates per treatment and 10 pigs per replicate. Five treatments were designated as follows according to the source of chromium. i) Control (No chromium): corn-soybean meal based basal diet, ii) $CrCl_{3}$: control diet+200 ppb Cr as $CrCl_{3}$, iii) CrPic: control diet+200 ppb Cr as Cr picolinate, iv) CrMet-1: control diet+100 ppb Cr as Cr methionine, and v) CrMet-2: control diet+200 ppb Cr as Cr methionine. After the feeding trial, three pigs per replicate (12 pigs per treatment) were slaughtered for the evaluation of carcass traits. Average daily gain (ADG), average daily feed intake (ADFI), and feed: gain ratio (F/G) were not different (p>0.05) among dietary Cr sources. However, whole-period ADG of pigs fed CrPic, CrMet-1 and CrMet-2 diets was higher (p<0.05) than for the control diet. Nutrient digestibility was not different (p>0.05) among dietary Cr sources, but the nutrient digestibility of pigs fed CrPic, CrMet-1 and CrMet-2 diets was higher (p<0.05) than for the control diet. BUN level decreased with more magnitude (p<0.05) in pigs fed Cr during the 20 to 50 kg period. Although both serum cholesterol and triglyceride were different (p<0.05) among treatments, there was no consistent response that could be related to the dietary Cr sources regardless of growth phase. However, the overall data suggested that serum cholesterol level increased as BW of pigs increased. Blood total protein (TP) increased (p<0.05) in pigs fed Cr only during the 90-110 kg phase, and blood creatinine (Creat) level was higher in $CrCl_{3}$ and CrPic treatments than in the control only during the 90-110 kg phase. Backfat thickness was thinner (p<0.05) in pigs fed CrMet-2 than in the control treatment. Therefore, lean percentage was higher (p<0.05) in CrMet-2 than in control pigs. However, dressing percentage and Longissimus muscle area (LMA) were not different (p>0.05) among treatments. In conclusion, dietary supplementation of 200 ppb Cr, via either CrPic or CrMet, improved pig growth performance and nutrient digestibility. Moreover, dietary CrMet supplementation for the growing-finishing pig is evidently remarkable for improving both lean percentage of the carcass and backfat thickness.

Kinetics of Cr(VI) Sorption/Reduction from Aqueous Solution on Activated Rice Husk

  • El-Shafey, E.I.;Youssef, A.M.
    • Carbon letters
    • /
    • v.7 no.3
    • /
    • pp.171-179
    • /
    • 2006
  • A carbonaceous sorbent was prepared from rice husk via sulphuric acid treatment. After preparation and washing, the wet carbon with moisture content 85% was used in its wet status in this study due to its higher reactivity towards Cr(VI) than the dry carbon. The interaction of Cr(VI) and the carbon was studied and two processes were investigated in terms of kinetics and equilibrium namely Cr(VI) removal and chromium sorption. Cr(VI) removal and chromium sorption were studied at various initial pH (1.6-7), for initial Cr(VI) concentration (100 mg/l). At equilibrium, maximum Cr(VI) removal occurred at low initial pH (1.6-2) where, Cr(III) was the only available chromium species in solution. Cr(VI) removal, at such low pH, was related to the reduction to Cr(III). Maximum chromium sorption (60.5 mg/g) occurred at initial pH 2.8 and a rise in the final pH was recorded for all initial pH studied. For the kinetic experiments, approximate equilibrium was reached in 60-100 hr. Cr(VI) removal data, at initial pH 1.6-2.4, fit well pseudo first order model but did not fit pseudo second order model. At initial pH 2.6-7, Cr(VI) removal data did not fit, anymore, pseudo first order model, but fit well pseudo second order model instead. The change in the order of Cr(VI) removal process takes place in the pH range 2.4-2.6 under the experimental conditions. Other two models were tested for the kinetics of chromium sorption with the data fitting well pseudo second order model in the whole range of pH. An increase in cation exchange capacity, sorbent acidity and base neutralization capacity was recorded for the carbon sorbent after the interaction with acidified Cr(VI) indicating the oxidation processes on the carbon surface accompanying Cr(VI) reduction.

  • PDF

Urine Specific Gravity as a Useful Tool for Screening Proteinuria in Children (소아 단백뇨 검사에 있어서 요비중의 유용성)

  • Kim, Jong-Hwa;Yoo, Kee-Hwan;Hong, Young-Sook;Lee, Joo-Won;Kim, Soon-Kyum
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.1-5
    • /
    • 2000
  • Purpose: The plcr of spot urine has been uised to predict the timed urine protein excretion. Although this method reduces errors caused by variations in urine volume, it is relatively thconvenient and expensive. Recently, a more rapid and less expensive screening method with specific gravity(SG) has been reported, and we have examined whether estimated-creatinine(Cr-est) with urine 5G could be used in place of urine creatinine to predict 24-hour collected urine protein excretion in children. Methods: We had retrospectively analyzed protein, creatinine and urine SG in randomized spot urine samples of 147 patients from March 1998 till June 1998 in Korea university Guro hospital and compared the urinary protein creatinine ratio(P/Cr) with the protein estimated-creatinine ratio(P/Cr-est). We compared the correlation of urinary creatinine vs-urine 5G with the timed urine pretein excretion. Results: 1) urine SG accurately estimated urine creatinine concentration (r=0.407, P<0.001, Cr=SG x 4485.82-4482.87). 2) P/Cr correlated with urine protein excretion measured in a 24-hour urine collection (r=0.771, P<0.001, 24-hour collected urine protein : 0.338 x (P/Cr) 4+667.885). 3) P/Cr-est correlated with a 24-hour collected urine protein (r=0.723, P<0.001, 24-hour collected urine protein =0.354 x (P/Cr-est)+726.044), Conclusions: These results suggest that P/Cr-est with urine SG could be useful method for screening proteinuria in children.

  • PDF

The Properties of Alloyed Ohmic Contact to p-InP (p-InP의 저항성 합금 접촉 특성 연구)

  • 이중기;박경현;한정희;이용탁
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.27 no.4
    • /
    • pp.555-562
    • /
    • 1990
  • Alloyed ohmic contact properties of Au-Zn/Au, Au-Be/Au,Au-Zn/Cr/Au, and Au-Be/Cr/Au metal system to p-InP were investigated. Optimum alloying conditions were obtained at the annealing temperature of 425\ulcorner for all the metal systems using a rapid thermal annealing system. Surface AES analysis and auger depth profiling were done for each metal system annealed at the optimum conditions. Outdiffusions of In and P from the InP substrate were found in the metal systems without Cr intermediate layer. Also, small amount of In. P and Cr were detected at the surface in the case of Au-Zn/Cr/Au system, while there were occured no outdiffusion of In, P, and Cr for Au-Be/Cr/Au system. The best surface morpholoty and specific contact resistivity of 4.5x 10**-5 \ulcornercm\ulcornerhave been obtained in this Au-Be/Cr/Au material system alloyed at 425\ulcorner for 60 second.

  • PDF

Cr(VI) Removal from Artificial Groundwater by Granular Activated Carbon and Regeneration of the Spent Carbon (입상활성탄을 이용한 인공 조제 지하수내의 Cr(VI) 제거와 그 활성탄의 재생)

  • Ihnsup Han
    • Journal of Korea Soil Environment Society
    • /
    • v.4 no.2
    • /
    • pp.11-31
    • /
    • 1999
  • Removal of hexavalent chromium from artificial groundwater (AGW) by granular activated carbon (GAC) was investigated in batch and continuous-flow column studies. Experimental parameters that were examined included solution pH, presence of dissolved oxygen (DO), and GAC pretreatment with Fe(II). As the solution pH increased from 4 to 7.5, the amount of Cr(VI) removed by both GACs decreased significantly. Exclusion of DO from the experimental systems resulted in greater removal of Cr(VI) from solution, possibly as a result of reduction to Cr(III). However, pretreatment of the GAC with a reductant (Fe(II)) did not improve Cr(VI) removal. Equilibration With 0.01 M $K_2$$HPO_4$[to extract adsorbed Cr(VI)] followed by a wash with 0.02 N $K_2$$HPO_4$[to remove precipitated/sorbed Cr(III)] proved to be a viable approach for the regeneration of carbons whose Cr(VI) removal capacities had been exhausted. The performance of the regenerated carbons exceeded that of the virgin carbons, primarily because of the favorable adsorption of Cr(VI) at lower pH values and the reduction of Cr(VI) to Cr(III), The presence of Cr(III) in acid wash solutions provides direct evidence that Cr(VI) is reduced to Cr(III) in GAC systems under relatively acidic conditions. GAC performance over five complete cycles was consistently high, which suggests that such a system will be able to function over many operation cycles without deleterious effects.

  • PDF

Evaluations of Inhomogeneous Shimming in $^1$H MR Spectroscopy (자기공명분광에서 비균질 자장보정에 관한 평가)

  • Choe, Bo-Young;Baik, Hyeon-Man;Suh, Tae-Suk;Lee, Hyoung-Koo;Chun, Heung-Jae;Shim, Kyung-Sub
    • Progress in Medical Physics
    • /
    • v.11 no.1
    • /
    • pp.73-83
    • /
    • 2000
  • In this study, we investigate the effects of poor shimming on quantitative measurement of ratios of metabolite levels by proton magnetic resonance spectroscopy ($^1$H MRS). Coefficient of variation (COV) of metabolite ratios for point resolved spectroscopy (PRESS) and stimulated-echo acquisition mode (STEAM) spectra was evaluated from a phantom containing in vivo levels of metabolites using a conventional whole body 1.5T MR system and conventional acquisition and analysis protocol. A statistical P-value was also calculated from a linear regression for relationship of metabolite ratios. N-acetylaspartate (NAA)/ creatine (Cr) and NAA/ choline (Cho) had low COV values for the long and short TE spectra (29.1 and 27.5%; 23.8 and 12.6 %), whereas Cho/Cr and Cr/Cho had high COV values (50.0 and 68.6 %; 27.5 and 29.3 %). A linear relationship between NAA/Cr and Cho/Cr, and between NAA/Cho and Cr/Cho revealed the statistical significance in the long and short TE spectra, respectively (P < 0.0001 and P < 0.0001; P = 0.015 and P = 0.005). There was no significant relationship between Cho/NAA and Cr/NAA in the measurement (P = 0.159; P = 0.910). The present study suggested that NAA/Cr and NAA/Cho could be useful for data with poor shimming in $^1$H MR spectroscopy. In conclusion, statistical significance of metabolite ratios indicated that the Cr and Cho levels could be interpreted as a significant alteration factor in the long and short TE spectra, and then should be used with care to provide precise metabolite quantification.

  • PDF

CR MANIFOLDS OF ARBITRARY CODIMENSION WITH A CONTRACTION

  • Kim, Sung-Yeon
    • The Pure and Applied Mathematics
    • /
    • v.17 no.2
    • /
    • pp.157-165
    • /
    • 2010
  • Let (M,p) be a germ of a $C^{\infty}$ CR manifold of CR dimension n and CR codimension d. Suppose (M,p) admits a $C^{\infty}$ contraction at p. In this paper, we show that (M,p) is CR equivalent to a generic submanifold in $\mathbb{C}^{n+d}$ defined by a vector valued weighted homogeneous polynomial.