• Title/Summary/Keyword: protection level

Search Result 2,211, Processing Time 0.029 seconds

Environmental Radiation Protection in Medical Institutions

  • Han, Eun-Ok;Dong, Kyung-Rae
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.3
    • /
    • pp.91-95
    • /
    • 2010
  • The study aimed to measure the levels of radiation protection for radiologists in medical institutions in three environmental categories (physical, administrative and social) and to establish a data base which can be used to increase awareness of environmental radiation protection in medical institutions within Korea. The study surveyed 10% of radiologists working in radiology departments in medical institutions which are supervised by the National Dose Registry overseen by the Korean Food and Drug Administration(KFDA). This study found that the level of environmental radiation protection was higher in the capital area and in larger hospitals. On the other hand, the study shows environmental radiation protection was lower in the Youngnam area and in clinics. Results from the questionnaires indicate the level of environmental radiation protection was higher when radiologists were given an individual dosimeter but lowest when the radiation protection apron quality test was conducted. Environmental radiation protection is an important factor for radiologists to conduct activities in a safe and protected environment. However, this study shows there are differences in the level of environmental radiation protection in medical institutions and location within Korea. In particular, the level of environmental radiation protection was lower in clinics, appropriate intervention strategies befitting these conditions are needed based on medical institution classification and location in order to improve the level of environmental protection.

A Study on determining Flood Protection Elevation in Urban Area (도시지역 방어침수위 설정에 관한 연구)

  • Shin, Sang-Young;Lee, Yang-Jae
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.649-652
    • /
    • 2008
  • In urban area, flood risk is getting higher because of inland flood risk has grown up by changing rainfall intensity, rainfall pattern, changing land use and so on. Urban area is needed higher flood protection level to protect accumulated people, buildings and other infrastructures. However, even though former flood protection has focused on overflow from river, there is not a guide line for evaluating proper flood protection level. Thus, it is necessary to protect flood from inland flooding as well as overflow from river and need a proper method to evaluating flood protection level. This study present a method of determining flood protection elevation by using GIS tools for deciding proper flood protection level. The study result may contribute to urban flood protection measures in which inland flood risk increases.

  • PDF

Analysis of GBAS Availability and Requirement with respected to Protection Level at Jeju International Airport (제주 국제 공항의 Protection Level 관점에서 GBAS 가용성 및 요구 조건 분석)

  • Ahn, Jong-Sun;Won, Dae-Hee;Sung, San-Kyung;Heo, Moon-Beom;Lee, Eun-Sung;Lee, Young-Jae
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.10
    • /
    • pp.946-951
    • /
    • 2011
  • This paper presents the simulation results of GBAS availability and requirement (with respected to Vertical Protection Level) using simulated data at CAT I, CAT II/III DH point (Decision Height), which are generated using Jeju international GNSS reference position, aircraft horizontal velocity and reference/aircraft GNSS antenna performance index and so on. Two kinds of protection levels are presented, one is from a hypothesis (H0) and other is from a alternative hypothesis (H1). These protection levels are compared with AL (Alert Limit), and we analyse the GBAS availability and requirement for CAT I and CAT II/III at the airport.

A Study on the Method for Judging the EMP Protection Plan and Required Level through Decision Making (의사결정론을 통한 EMP 방호대책 및 수준 판단방안 제시에 관한 연구)

  • Kim, Kuk-Joo;Park, Sang-Woo;Baek, Jang-Woon;Park, Young-Jun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.2
    • /
    • pp.193-200
    • /
    • 2019
  • In the context of increasing threats of EMP by neighboring countries in the security situation on the Korean peninsula, EMP protection facilities are a very important means of ensuring military operational capability. These EMP protection facilities should be constructed by comprehensively judging various factors about operation units. However, Defense Military Facilities Criteria and National Technical Guideline for EMP protection require at least 80dB shielding effectiveness without considering other options. In this study, we use objective and statistical methods to refine the consideration of the required EMP protection level based on the opinions of the experts. To do this, the Delphi technique is used for this study, and the survey was conducted from 53 experts related to EMP protection standard in the military and civilian sectors. The first questionnaire investigated the appropriate level of EMP protection, and the second questionnaire analyzed the factors considered in establishing EMP protection level. As a result of the factor analysis on the opinions of the experts, it was concluded that the EMP protection requirement level should be determined by variables of METT + TC.

Trend and Analysis of Protection Level Calculation Methods for Centimeter-Level Augmentation System in Maritime

  • Jaeyoung Song;TaeHyeong Jeon;Gimin Kim;Sang Hyun Park;Sul Gee Park
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.12 no.3
    • /
    • pp.281-288
    • /
    • 2023
  • The International Maritime Organization (IMO) states that the recommended horizontal accuracy for coastal and offshore areas is 10 m, the Alert Limit (AL) is 25 m, the time to alert is 10 seconds, and the integrity risk (IR) is 10-5 per three hours. For operations requiring high accuracy, such as tugs and pushers, icebreakers, and automated docking, the IMO dictates that a high level of positioning accuracy of less than one meter and a protection level of 0.25 meters (for automated docking) to 2.5 meters should be achieved. In this paper, we analyze a method of calculating the user-side protection level of the centimeter-level precision Global Navigation Satellite System (GNSS) that is being studied to provide augmentation information for the precision Positioning, Navigation and Timing (PNT) service. In addition, we analyze standardized integrity forms based on RTCM SC-134 to propose an integrity information form and generate a centimeter-level precise PNT service plan.

Protection Level Evaluation of Distribution Systems Based on Dempster-Shafer Theory of Evidence (Dempster-Shafer 증거 이론을 이용한 배전계통 보호도 평가)

  • Kim, He-Chul;Lee, Seung-Jae;Kang, Sang-Hee;Ahn, Bok-Shin;Park, Jong-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.896-898
    • /
    • 1998
  • Recent development of the digital computer and communication technology has made the concept of the adaptive protection possible, which is to adapt the operating parameters of the protective devices to the system changes, so that the best protection function can be maintained all the time. In order to achieve the adaptive protection, it is necessary to have the way to determine whether the change of the settings is needed under the certain system change or how good the current protection level is. This paper proposed the protectability index, which is a way to evaluate the protection level of the system under arbitary conditions and the operating strategy of the adaptive protection utilizing this index. It is based on an hierachical evaluation model and the evidence combination rule of the Dempster-Shafer theory.

  • PDF

A Source-Related Approach for Discussion on Using Radionuclide-Contaminated Materials in Post-accident Rehabilitation

  • Kazuji Miwa;Takeshi Iimoto
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.68-76
    • /
    • 2023
  • Background: In the process of discussion on the possibility of using radionuclide-contaminated soil and debris generated by radiation disasters, a strategy for the proper management of radiation exposure protection while considering the source of the contaminated materials is necessary. Materials and Methods: The radiological protection criteria that are likely to be applied to the source-related approach based on the International Commission on Radiological Protection recommendations and the International Atomic Energy Agency safety standards are summarized. We proposed five interpretations of radiation protection to contribute to the promotion of discussion on the possibility of using a part of low-level-radionuclide-contaminated soil and debris in the post-accident rehabilitation. Interpretations I to III are based on the idea of "using a reference level to protect the public in post-accident rehabilitation," whereas IV and V are based on the idea of "using the dose constraint to protect the public in the post-accident rehabilitation when the sources are handled in a planned activity." The former idea is subdivided into three based on the definition of the source, which is managed by the reference level, and the latter idea is divided into two depending on whether or not additional dose from using contaminated materials is deemed acceptable. Results and Discussion: To confirm the applicability of the five interpretations presented, we suggested the concrete values of protection criteria via two feasible cases. In this case study, we proposed radiation protection by the dose constraint based on the Interpretation IV and chose 1 mSv/yr for the public and 20 mSv/yr for workers dealing with radionuclide-contaminated materials. Conclusion: We concretely and systematically demonstrated how the concept of radiation protection can be applied to the process of discussion on the possibility of using radionuclide-contaminated materials within the framework of an international system of protection. This study's findings can provide necessary information to discuss the possibility of using radionuclide-contaminated materials as an alternative option for recovery and reconstruction after a radiation disaster from the viewpoint of radiation protection.

A Study for the Designing and Efficiency Measuring Methods of Integrated Multi-level Network Security Domain Architecture (Multi-level 네트워크의 보안 도메인을 위한 통합 아키텍쳐 설계 및 효율성 측정방법 연구)

  • Na, Sang Yeob;Noh, Si Choon
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.5 no.4
    • /
    • pp.87-97
    • /
    • 2009
  • Internet network routing system is used to prevent spread and distribution of malicious data traffic. This study is based on analysis of diagnostic weakness structure in the network security domain. We propose an improved integrated multi-level protection domain for in the internal route of groupware. This paper's protection domain is designed to handle the malicious data traffic in the groupware and finally leads to lighten the load of data traffic and improve network security in the groupware. Infrastructure of protection domain is transformed into five-stage blocking domain from two or three-stage blocking. Filtering and protections are executed for the entire server at the gateway level and internet traffic route ensures differentiated protection by dividing into five-stage. Five-stage multi-level network security domain's malicious data traffic protection performance is better than former one. In this paper, we use a trust evaluation metric for measuring the security domain's performance and suggested algorithm.

An Empirical Study on the Effect of Protection of Property Right on Foreign Direct Investment - Focused on US. Multinational Corporations - (지적재산권 보호가 해외직접투자 유입에 미치는 영향에 관한 실증연구 - 미국 다국적기업을 중심으로 -)

  • Kang, Seok-Min
    • Management & Information Systems Review
    • /
    • v.33 no.3
    • /
    • pp.21-33
    • /
    • 2014
  • This study investigated the effect of protection of property right on foreign direct investment. With the US. multinational corporations over the periods from 2000 to 2008, this study used the FEM and system GMM, and found that the change of protection of property right level positively affects attracting foreign direct investment while protection of property right level itself does not. In the analyses on high income and low income countries(by income level), only the change of protection of property right level positively affects attracting foreign direct investment in low income countries. In considering the problem of heteroscedasticity on the error term, this study used FGLS and PCSE estimation methods. It is reported that the change of protection of property right level positively affects attracting foreign direct investment while protection of property right level itself does not. And only the change of protection of property right level positively affects attracting foreign direct investment in low income countries. This result means the change of protection of property right level is a key determinant to attract foreign direct investment.

  • PDF