• Title/Summary/Keyword: quality check

Search Result 1,024, Processing Time 0.029 seconds

Development of Check-list for BIM Based Architectural Design Quality Check (BIM 기반 건축설계 품질검토를 위한 체크리스트 개발 연구)

  • Choi, Jungsik;Kim, Inhan
    • Korean Journal of Computational Design and Engineering
    • /
    • v.18 no.3
    • /
    • pp.177-188
    • /
    • 2013
  • The construction industry consists of various and massive architectural information as an architectural process includes a variety of design stages with cooperation of many disciplines. Particularly, architectural information is generated and managed through the life cycle of a building, from conceptual design stage to the construction and maintenance. A Building Information Model (BIM) serves as a shared knowledge resource for information about a facility forming a reliable basis for decisions during its life-cycle from inception onward. BIM technology accomplished quantitative development being utilized in various disciplines. However, it is necessary to develop environment and requirement for qualitative improvement of BIM based project. Particularly, requirement is very important for architectural design evaluations. The purpose of this study is to develop and apply of quality control check-list for improving the quality of architectural design in BIM environments. To achieve this purpose, the authors have investigated case study for open BIM data quality control (software, guideline and application case) and classified quality control targets according to physical/logical quality control and data quality. In addition, the authors have defined open BIM based quality control process and developed quality control check-list. Finally, the authors have developed automatic quality check system using requirements for efficient quality control based on open BIM.

Development of a Quality Check Algorithm for the WISE Pulsed Doppler Wind Lidar (WISE 펄스 도플러 윈드라이다 품질관리 알고리즘 개발)

  • Park, Moon-Soo;Choi, Min-Hyeok
    • Atmosphere
    • /
    • v.26 no.3
    • /
    • pp.461-471
    • /
    • 2016
  • A quality check algorithm for the Weather Information Service Engine pulsed Doppler wind lidar is developed from a view point of spatial and temporal consistencies of observed wind speed. Threshold values for quality check are determined by statistical analysis on the standard deviation of 3-component of wind speed obtained by a wind lidar, and the vertical gradient of horizontal wind speed obtained by a radiosonde system. The algorithm includes carrier-to-noise ratio (CNR) check, data availability check, and vertical gradient of horizontal wind speed check. That is, data sets whose CNR is less than -29 dB, data availability is less than 90%, or vertical gradient of horizontal wind speed is less than $-0.028s^{-1}$ or larger than $0.032s^{-1}$ are classified as 'doubtful', and flagged. The developed quality check algorithm is applied to data obtained at Bucheon station for the period from 1 to 30 September 2015. It is found that the number of 'doubtful' data shows maxima around 2000 m high, but the ratio of 'doubtful' to height-total data increases with increasing height due to atmospheric boundary height, cloud, or rainfall, etc. It is also found that the quality check by data availability is more effective than those by carrier to noise ratio or vertical gradient of horizontal wind speed to remove an erroneous noise data.

A Study on Methods of Quality Check for Digital Basemaps using Statistical Methods for the Quality Control (통계적 품질관리기법을 도입한 수치지도의 검수방법에 관한 연구)

  • 김병국;서현덕
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.17 no.1
    • /
    • pp.79-86
    • /
    • 1999
  • In this study, we investigated methods of quality check for digital basemaps and proposed effective methods of quality check. We used new statistical methods for quality control in order to carry out quality check for digital basemaps. We proposed 2-stage complete sampling and 2-stage cluster sampling method to improve present statistical methods of quality check(1-stage complete sampling method). We estimated error rate and number of omitted objects using simulated data about all delivered digital basemaps and estimated variances about it. We could determine confidence interval about error rate and number of omitted objects.

  • PDF

Validation of Quality Control Algorithms for Temperature Data of the Republic of Korea (한국의 기온자료 품질관리 알고리즘의 검증)

  • Park, Changyong;Choi, Youngeun
    • Atmosphere
    • /
    • v.22 no.3
    • /
    • pp.299-307
    • /
    • 2012
  • This study is aimed to validate errors for detected suspicious temperature data using various quality control procedures for 61 weather stations in the Republic of Korea. The quality control algorithms for temperature data consist of four main procedures (high-low extreme check, internal consistency check, temporal outlier check, and spatial outlier check). Errors of detected suspicious temperature data are judged by examining temperature data of nearby stations, surface weather charts, hourly temperature data, daily precipitation, and daily maximum wind direction. The number of detected errors in internal consistency check and spatial outlier check showed 4 days (3 stations) and 7 days (5 stations), respectively. Effective and objective methods for validation errors through this study will help to reduce manpower and time for conduct of quality management for temperature data.

Current Status and Appropriate Check Method of Construction Quality Control for Rebar Coupler Splice (철근 커플러이음의 시공품질 확인 현황 및 적정 시공품질 확인 방안)

  • Kim, Ju-Yong;Kim, Jin-Dong;Lee, Young-Do;Kim, Gwang-Hee
    • Journal of the Korea Institute of Building Construction
    • /
    • v.22 no.6
    • /
    • pp.531-542
    • /
    • 2022
  • As buildings become taller, the strength of structural materials must increase and the amount of rebar reinforcement also increases while the application of an appropriate rebar splice method in the construction process become one of the essential factors. In this research, the current status of quality check for rebar coupler is identified by an expert questionnaire and an appropriate quality check method is proposed through a quality test on specimens similar to actual on-site construction. In the test results, it was revealed that, among the quality check methods for rebar coupler joints, the coupler tightening method and face to face degree of between upper and lower rebar did not affect the strength the specimen. Therefore, it is considered to be an appropriate way to check the coupler quality check to check whether the threads are completely assembled during on-site construction through manufacture the number of threads of rebar and coupler with a margin beyond the calculated thread number.

Improvement and Evaluation of Automatic Quality Check Algorithm for Particulate Matter (PM10) by Analysis of Instrument Status Code (부유분진(PM10) 측정기 상태 코드 분석을 통한 자동 품질검사 알고리즘 개선 및 평가)

  • Kim, Mi-Gyeong;Park, Young-San;Ryoo, Sang-Boom;Cho, Jeong Hoon
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.501-509
    • /
    • 2019
  • Asian Dust is a meteorological phenomenon that sand particles are raised from the arid and semi-arid regions-Taklamakan Desert, Gobi Desert and Inner Mongolia in China-and transported by westerlies and deposited on the surface. Asian dust results in a negative effect on human health as well as environmental, social and economic aspects. For monitoring of Asian Dust, Korea Meteorological Administration operates 29 stations using a continuous ambient particulate monitor. Kim et al. (2016) developed an automatic quality check (AQC) algorithm for objective and systematic quality check of observed PM10 concentration and evaluated AQC with results of a manual quality check (MQC). The results showed the AQC algorithm could detect abnormal observations efficiently but it also presented a large number of false alarms which result from valid error check. To complement the deficiency of AQC and to develop an AQC system which can be applied in real-time, AQC has been modulated. Based on the analysis of instrument status codes, valid error check process was revised and 6 status codes were further considered as normal. Also, time continuity check and spike check were modified so that posterior data was not referred at inspection time. Two-year observed PM10 concentration data and corresponding MQC results were used to evaluate the modulated AQC compared to the original AQC algorithm. The results showed a false alarm ratio decreased from 0.44 to 0.09 and the accuracy and the probability of detection were conserved well in spite of the exclusion of posterior data at inspection time.

Site Quality Evaluation Prototype for Building Deck-plate Construction

  • Shim, Young-Bo;Cho, Dong-Hyun;Koo, Kyo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.13 no.1
    • /
    • pp.90-100
    • /
    • 2013
  • Deck-plates are widely used on construction sites, and have the advantage of enabling contractors to achieve a relatively uniform quality. But nevertheless, quality deviation in deck-plate construction can occur as the result of differences in site conditions and the experience of crew workers. In this study, the authors present a site quality evaluation prototype for building deck-plate construction. Through analyses of case studies and interviews with experts, standard quality check sheets and a quality management index were developed by estimating the importance of quality check items based on a Failure Mode and Effects Analysis (FMEA) method. The applicability and effectiveness of the prototype was evaluated through a case study and interviews with case participants. It was found that the prototype promoted an active quality management as a way of continuously improving quality management in deck-plate construction instead of passive quality inspection practice.

Consistency Check of a House of Quality Chart by Limiting Probability Concept and Median Rank (극한확률의 개념과 Median Rank를 이용한 HOQ 도표의 일관성 검정)

  • Won, Yu-Woong;Kim, Ki-Young;Yun, Deok-Kyun
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.33 no.3
    • /
    • pp.22-29
    • /
    • 2010
  • Six sigma has been the most influential management innovation tool in order to achieve the customer's satisfaction and keep the competition in the age of limitless competition. The success in six sigma is to find the correct CTQ (Critical to Quality). QFD (Quality function deployment) is the efficient too ever created to tie product and service design decisions directly to customer wants and needs. One of the mistakes in QFD is to analyze using an inconsistent HOQ (House of quality) chart. An inconsistent HOQ chart is one in which the information from the correlation matrix is inconsistent with that from the relationship matrix. This study presents the consistency check and inconsistency check in case of failing the consistency check. Also we propose the procedures using the Limiting Probability in correlation matrix and the Median Rank in relationship matrix in order to be consistent in HOQ chart.

Examining User Perception about Airline Untact Service Quality (항공사 비대면 서비스 품질에 대한 이용자 인식 연구)

  • Lee, Sojeong;An, Jaeyoung;Yun, Haejung
    • Journal of Korean Society for Quality Management
    • /
    • v.50 no.3
    • /
    • pp.545-570
    • /
    • 2022
  • Purpose: The purpose of this study was to explore dimensions to improve airline non-face-to-face(untact) service quality and identify shadow work dimensions in the digital environment among them. Methods: This study conducted mixed method. First of all, For finding out the dimensions of airline untact service quality, in-depth interviews were conducted from passengers. The collected data through the survey were analyzed using improved importance-performance analysis(IPA). Second, An online survey was conducted to quantitatively analyze user perception about airline untact service quality, and the importance performance of service quality at each dimension was identified through the revised IPA method. Results: The results of this study are as follows; Through in-depth interviews, 11 dimensions found out and 32 measurement items were developed. and then, through the revised IPA analysis, passengers were highly satisfied with "Cleanliness of in-flight service" and "Reliability of self check-in". Also, We found 3 shadow work dimensions such as "Ease of use of self check-in", "Usefulness of self check-in", and "Responsiveness of self check-in". Conclusion: Airline service providers have to keep high-satisfaction services and urgently improve less satisfied services. In particular, the dimensions related to shadow work have to be improved.

Development and Assessment of Real-Time Quality Control Algorithm for PM10 Data Observed by Continuous Ambient Particulate Monitor (부유분진측정기(PM10) 관측 자료 실시간 품질관리 알고리즘 개발 및 평가)

  • Kim, Sunyoung;Lee, Hee Choon;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.541-551
    • /
    • 2016
  • A real-time quality control algorithm for $PM_{10}$ concentration measured by Continuous Ambient Particulate Monitor (FH62C14, Thermo Fisher Scientific Inc.) has been developed. The quality control algorithm for $PM_{10}$ data consists of five main procedures. The first step is valid value check. The values should be within the acceptable range limit. Upper ($5,000{\mu}g\;m^{-3}$) and lower ($0{\mu}g\;m^{-3}$) values of instrument detectable limit have to be eliminated as being unrealistic. The second step is valid error check. Whenever unusual condition occurs, the instrument will save error code. Value having an error code is eliminated. The third step is persistence check. This step checks on a minimum required variability of data during a certain period. If the $PM_{10}$ data do not vary over the past 60 minutes by more than the specific limit ($0{\mu}g\;m^{-3}$) then the current 5-minute value fails the check. The fourth step is time continuity check, which is checked to eliminate gross outlier. The last step is spike check. The spikes in the time series are checked. The outlier detection is based on the double-difference time series, using the median. Flags indicating normal and abnormal are added to the raw data after quality control procedure. The quality control algorithm is applied to $PM_{10}$ data for Asian dust and non-Asian dust case at Seoul site and dataset for the period 2013~2014 at 26 sites in Korea.