• Title/Summary/Keyword: radial pulse

Search Result 191, Processing Time 0.028 seconds

Implementation of Radial Pulse Diagnosis System using Inyoung-Cheongu Comparison Method (인영.촌구 대비법을 이용한 맥 진단 시스템 구현)

  • Lee, Ho-Jae;Park, Young-Bae;Huh, Woong
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1993
  • This paper describes the implementation of a computerized radial pulse diagnosis by Elds of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diag nosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed It. Then, we have got the characteristic parameters of radial pulse wave and also quantified thats according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial Pulse diagnosis system and then we confirmed the PossibiliLy for realization of automatic radial Pulse diagnosis in korean traditional medicine.

  • PDF

Immobilization of Heparin onto the Polyurethane

  • Cho, Chong-Su;Kim, Sung-Wan
    • Journal of Biomedical Engineering Research
    • /
    • v.7 no.2
    • /
    • pp.147-150
    • /
    • 1986
  • This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine.

  • PDF

A study on Radial pulse diagnosis of the korean medicine (한방 맥 진단에 관한 연구)

  • Lee, H.J.;Kim, J.W.;Huh, W.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.71-74
    • /
    • 1992
  • This paper describes research about the realization of computerized radial pulse diagnosis system in order to remove the subjectivity of a diagnostician, when diagnostician diagnoses a sickness using tactile percept ion in korean traditional medicine. Using radial pulse wave detection system, we effectively measured pressure radial pulse rave and after analyzing it, we detected the characteristic parameters and also quantified it and then we objectified more or less the judgement standard of radial pulse diagnosis by the aids of a clinical expert. on this base, we confirmed the possibility for realizing of automatic radial pulse diagnosis by radial pulse diagnosis system.

  • PDF

The Effect of Sa-Am Stomach Tonifying Acupuncture on Radial Pulse in Healthy Human Subjects (위정격(胃正格) 자침이 정상 성인의 맥파(脈波)에 미치는 영향)

  • Choi, Joo Young;Kang, Jae Hui;Yim, Yun Kyong;Lee, Hyun
    • Journal of Acupuncture Research
    • /
    • v.29 no.6
    • /
    • pp.57-71
    • /
    • 2012
  • Objectives : The purpose of this study is to find the effects of Sa-Am stomach tonifying acupuncture on radial pulse through the parameters difference. Methods : Forty healthy subjects participated in this study, acupuncture group and control group were divided. Radial pulse were measured using 3 dimensional pulse imaging system(DMP-3000). 19 parameters that significantly changed were selected after comparing between acupuncture group and control group. Then, 19 parameters were analyzed before, immediately after, 30 minutes after and 60 minutes after acupuncture in acupucture group. Results : 1. Heart rate, pulse period, T/T1, T2/T, T4/T, T5/T, T-T4, (T-T4)/T and T4/(T-T4) significantly changed after acupuncture. 2. H1 Amplitude, H2 Amplitude, H4 Amplitude and H5 Amplitude significantly changed after acupuncture. 3. Area of Pulse Wave, Systolic Pulse Area, Diastolic Pulse Area and Area of W significantly changed after acupuncture. 4. AIx/HR significantly changed after acupuncture. Conclusion : Stomach Tonifying Acupuncture exerts an influence on radial pulse parameters. Further radial pulse change study on various acupuncture treatment is required.

Precise Measurement Method of Radial Artery Pulse Waveform using Robotic Applanation Tonometry Sensor (로보틱 토노메트리 센서를 이용한 요골 동맥 파형 정밀 측정 방법)

  • Kim, Young-Min
    • Journal of Sensor Science and Technology
    • /
    • v.26 no.2
    • /
    • pp.135-140
    • /
    • 2017
  • In this paper, a novel measurement method of radial artery pulse waveform using robotic applanation tonometry (RAT) was present to reduce the errors by the pressing direction of the vessel. The RAT consisted of an array of pressure sensors and 2-axis tilt sensor, which was attached to the universal joint with a linear spring and five-DOF robotic manipulator with a one-axis force sensor. Using the RAT mechanism, the pulse sensor could be manipulated to perpendicularly pressurize the radial artery. A pilot experimental result showed that the proposed mechanism could find the optimal pressurization angles of the pulse sensor within ${\pm}3^{\circ}$standard deviations. Coefficient values of variation of maximum pulse peaks extracted from the pulse waveforms were 4.692, 6.994, and 11.039 % for three channels with the highest magnitudes. It is expected that the proposed method can be helpful to develop more precise tonometry system measuring the pulse waveform on the radial artery.

The Classification and Frequency Analysis in Radial Pulse (맥파의 인식상의 분류와 주파수 해석)

  • Kil, S.K.;Han, S.H.;Kwon, O.S.;Park, S.H.;Hong, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.263-264
    • /
    • 1998
  • In this paper, we present the result of feature points recognition and classification of radial pulse by the shape of pulse wave. And we analyze radial pulse in frequency domain. The recognition algorithm use the method which runs in parallel with both the data of ECG and differential pulse simultaneously to recognize the feature points. Also fie specified 3-time elements of pulse wave as main parameters for diagnosis and measured them by execution of algorithm, then we classify the shape of radial pulse by existence and position of feature points. lastly we execute frequency analysis on the feature points and get the power spectrum of radial pulse.

  • PDF

The Effects of Sa-Am Acupuncture on the Radial Pulse in Healthy Human Subjects: A Comparative Study of Pericardium jung-gyuck and Triple Energizer jung-gyuck

  • Kim, Tae-Min;Kim, Jea-Hong;Lee, Hyun-Suk;Yim, Yun-Kyoung
    • The Journal of Korean Medicine
    • /
    • v.38 no.4
    • /
    • pp.41-54
    • /
    • 2017
  • Objectives: The purpose of this study is to investigate the effects of Sa-am acupuncture with Pericardium jung-gyuck (SA-acu-PC) and Triple Energizer jung-gyuck (SA-acu-TE) on the radial pulse in healthy human subjects. Methods: Sixty healthy subjects participated in this study and divided into three groups randomly: Control group(C), Pericardium jung-gyuck group(PC), Triple Energizer jung-gyuck group(TE). Radial pulse was measured by 3 dimensional pulse imaging system (DMP-3000) before, right after, 30 minutes after, and 60 minutes after acupuncture. Results: 1. The changes observed in periodic parameters are considered as the common effects of both SA-acu-TE and SA-acu-PC. SA-acu-TE was more effective than SA-acu-PC in these effects. 2. The effects of SA-acu-PC appeared in the pulse amplitude, pulse area, and pulse power volume mainly at the left chon position, and 3. The effects of SA-acu-TE appeared in the radial augmentation index and main peak angle mainly at the right gwan position. Conclusions: The effects of SA-acu-PC and SA-acu-TE can be observed in the radial pulse. The increases in pulse amplitude, pulse area, and pulse power volume at the left chon may imply the effects of SA-acu-PC. And the decrease in the pulse power volume, the increases in radial augmentation index and main peak angle may imply the effects of SA-acu-TE.

Detection of Radial Pulse Wave by Photoplethysmogram (광전용적맥파를 이용한 요골동맥 맥파 검출)

  • 정동근;김광년;연규선;최병철;서덕준
    • Journal of Life Science
    • /
    • v.13 no.1
    • /
    • pp.42-46
    • /
    • 2003
  • Photoplethysmogram is widely used to measure heart rate and arterial blood oxygen saturation in human. This paper describes radial pulse waves recorded by photoplethysmogram with 940 nm wavelength infra red light. Radial pulse waves were varied according to the recording site. When recorded on the skin over radial artery, the radial pulse wave was inverted, comparing to the photoplethysmogram at fingertip. The mechanism of inverted pulse wave seemed to be caused by the change of the blood volume in the subcutaneous tissue between radial artery and the skin, which was reduced during systolic period and increased during diastolic period of the cardiac cycle. These results suggest that radial arterial wall may reflect infra red ray.

The Effect of Food Intakes on Radial Pulse Amplitude (음식섭취에 따른 좌우(左右) 촌관척(寸關尺) 6부위 맥압 변화 연구)

  • Yim, Yun-Kyoung;Kang, Hee-Jung;Lee, Byung-Ryul;Yang, Gi-Young;Lee, Hyun;Kim, Kyung-Cheol
    • Korean Journal of Acupuncture
    • /
    • v.28 no.2
    • /
    • pp.13-22
    • /
    • 2011
  • Objectives : The purpose of this study is to investigate the effect of food intake on radial pulse amplitude. Methods : Thirty one healthy male subjects participated in this study. Radial pulse was measured using 3 dimensional pulse imaging system (DMP-3000) before, right after, 40 minutes after, 80 minutes after and 120 minutes after food intake. Results : 1. The amplitude of h1 increased significantly right after food intake compared to 'before food intake' at all 6 measuring points. Later on, it decreased back as time passed, however, even 120 minutes later, it was still higher than 'before food intake' 2. Pulse energy, which is calculated from pulse waves acquired with five sensors, increased after food intake as well. Conclusions : Food intake exerts an influence on radial pulse amplitude, resulting in increase of h1 and pulse energy.

The Effects of Sa-am Acupuncture on Radial Pulse in Healthy Human Subjects: A Comparative Study of Liver Tonifying and Sedating (간정격 및 간승격 자침이 정상 성인의 맥파에 미치는 영향 비교 연구)

  • Yuk, Dong Il;Jeon, Ju Hyun;Kim, Young Il;Kim, Jung Ho
    • Journal of Acupuncture Research
    • /
    • v.32 no.2
    • /
    • pp.169-185
    • /
    • 2015
  • Objectives : The purpose of this study is to find the effects of Sa-am liver tonifying and sedating acupuncture on radial pulse. Methods : Sixty healthy people were divided into a liver tonifying acupuncture(LTA) group, liver sedating acupuncture(LSA) group, and control group. The LTA group and LSA group received acupuncture for 20 minutes with a supine position. The Control group took a rest without receiving acupuncture. Radial pulse was measured by three dimensional pulse imaging system(DMP-3000) at four different time points (before, right after, 30 minutes after, and 60 minutes after acupuncture). We compared the three groups and figure out determined the parameters which significantly changed after acupuncture treatment. Results : 1. Pulse period, T1/T, T4/T, (T-T4)/T, T4/(T-T4), T5/T significantly changed after acupuncture. 2. H4, pulse area, systolic pulse area, diastolic pulse area, radial augmentation index(RAI), and pulse power volume / min significantly changed after acupuncture. 3. Frequency of Fourier components, ratio of frequencies of Fourier components, magnitude of Fourier components, and ratio of magnitudes of Fourier components significantly changed after acupuncture. Conclusions : LTA and LSA have an effect on the radial pulse parameters. Further studies on radial pulse change using Sa-Am acupuncture are needed.