• Title/Summary/Keyword: shaking table tests

Search Result 331, Processing Time 0.034 seconds

Effects of excess pore pressure dissipation on liquefaction-induced ground deformation in 1-g shaking table test

  • Wang, B.;Zen, K.;Chen, G.Q.;Kasama, K.
    • Geomechanics and Engineering
    • /
    • v.4 no.2
    • /
    • pp.91-103
    • /
    • 2012
  • Focusing on the effect of excess pore pressure dissipation on liquefaction-induced ground deformation, a series of 1-g shaking table tests were conducted in a rigid soil container by use of saturated Toyoura sand, the relative density of which was 20-60%. These tests were subjected to the sinusoidal base shaking with step increased accelerations: 100, 200, 300 and 400 Gals for 2-4 seconds. Shaking table tests were done using either water or polymer fluid with more viscous than water, thus varying the sand permeability of model tests. Excess pore pressures, accelerations, settlements and lateral deformations were measured in each test. Test results are presented in this paper and the effect of sand permeability on liquefaction and liquefaction-induced ground deformation was discussed in detail.

A Study on Similitude Law for Pseudodynamic Tests and Shaking Table Tests on Small-scale R/C Models (철근콘크리트 축소모형의 유사동적실험과 진동대 실험을 위한 상사법칙 연구)

  • Yang, Hui-Gwan;Seo, Ju-Won;Cho, Nam-So;Chang, Sung-Pil
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2006.03a
    • /
    • pp.545-552
    • /
    • 2006
  • Small-scale models have been frequently used for seismic performance tests because of limited testing facilities and economic reasons. However, there are not also enough studies on similitude law for analogizing prototype structures accurately with small-scale models, although conventional similitude law based on geometry similitude is not well consistent in their inelastic seismic behaviors. When fabricating prototype and small-scale model of reinforced concrete structures by using the same material, added mass is demanded from a volumetric change and scale factor could be limited due to aggregate size. Therefore, it is desirable to use different materials for small-scale model. In our recent study, a modified similitude law was derived depending on geometric scale factor, equivalent modulus ratio and ultimate strain ratio. And quasi-static and pseudo-dynamic tests on the specimens are carried out using constant and variable modulus ratios, and correlation between prototype and small-scale model is investigated based on their test results. In this study, tests on scaled model of different concrete compressive strength aye carried out. In shaking table tests, added mass can not be varied. Thus, constant added mass on expected maximum displacement was applied and the validity was verified in shaking table tests. And shaking table tests on non-artificial mass model is carried out to settle a limitation of acceleration and the validity was verified in shanking table tests.

  • PDF

Experimental identification of the six DOF C.G.S., Algeria, shaking table system

  • Airouche, Abdelhalim;Bechtoula, Hakim;Aknouche, Hassan;Thoen, Bradford K.;Benouar, Djillali
    • Smart Structures and Systems
    • /
    • v.13 no.1
    • /
    • pp.137-154
    • /
    • 2014
  • Servohydraulic shaking tables are being increasingly used in the field of earthquake engineering. They play a critical role in the advancement of the research state and remain one of the valuable tools for seismic testing. Recently, the National Earthquake Engineering Research Center, CGS, has acquired a 6.1m x 6.1 m shaking table system which has a six degree-of-freedom testing capability. The maximum specimen mass that can be tested on the shaking table is 60 t. This facility is designed specially for testing a complete civil engineering structures, substructures and structural elements up to collapse or ultimate limit states. It can also be used for qualification testing of industrial equipments. The current paper presents the main findings of the experimental shake-down characterization testing of the CGS shaking table. The test program carried out in this study included random white noise and harmonic tests. These tests were performed along each of the six degrees of freedom, three translations and three rotations. This investigation provides fundamental parameters that are required and essential while elaborating a realistic model of the CGS shaking table. Also presented in this paper, is the numerical model of the shaking table that was established and validated.

Tests of Visco-elastic-Damping Models Using A Small Shaking Table (소형진동대를 이용한 점탄성감쇠 모델실험)

  • 이한선
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.04a
    • /
    • pp.188-195
    • /
    • 1998
  • The main objective of this study is to observe the effect of visco-elastic damper on seismic behavior of structure. A small shaking table was designed and manufactured using the materials and machinery available in the market by the authors. Also, two small-scale models with and without visco-elastic dampers were made. Dynamic characteristics, such as natural periods and damping ratios, were measured with free vibration tests. Finally, the earthquake simulations tests by using this shaking table were performed to these models. Based on the test results, the effect of visco-elastic damper on the seismic response of models is evaluated.

  • PDF

Evaluation of the seismic performance of butt-fusion joint in large diameter polyethylene pipelines by full-scale shaking table test

  • Jianfeng Shi;Ying Feng;Yangji Tao;Weican Guo;Riwu Yao;Jinyang Zheng
    • Nuclear Engineering and Technology
    • /
    • v.55 no.9
    • /
    • pp.3342-3351
    • /
    • 2023
  • High-density polyethylene (HDPE) pipelines in nuclear power plants (NPPs) have to meet high requirements for seismic performance. HDPE pipes have been proved to have good seismic performance, but joints are the weak links in the pipelines, and pipeline failures usually initiate from the defects inside the joints. Limited data are available on the seismic performance of butt-fusion joints of HDPE pipelines in NPPs, especially in terms of defects changes inside the joints after earthquakes. In this paper, full-scale shaking table tests were performed on a test section of suspended HDPE pipelines in an NPP, which included straight pipes, elbows, and 10 butt-fusion joints. During the tests, the seismic load-induced strain of the joints was analyzed by strain gauges, and it was much smaller than the internal pressure and self-weight-induced strain. Before and after the shaking table tests, phased array ultrasonic testing (PA-UT) was conducted to detect defects inside the joints. The locations, numbers, and dimensions of the defects were analyzed. It was found that defects were more likely to occur in elbows joints. No new defect was observed after the shaking table tests, and the defects showed no significant growth, indicating the satisfactory seismic performance of the butt-fusion joints.

Technical Review on the Multipurpose Biaxial Shaking Table System (다목적 이축 진동시험 설비의 기술적 검토)

  • 안희재
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1998.10a
    • /
    • pp.163-172
    • /
    • 1998
  • The design fundamentals of the shaking tables are briefly discussed. In order to understand the recent trends in development of the shaking tables, the characteristics and performances of the major seismic testing facilities are investigated. The international standards related to the vibration tests using shaking table are also overviewed. The newly designed multipurpose biaxial shaking table of Hyundai Heavy Industries, Co., Ltd. is introduced. It has the capabilities to perform the vibration, shock and seismic qualification tests in two simultaneous and independent directions (vertical and horizontal directions). Since the shaking table adapts four extremely stiff torque instead of much more expensive hydraulic actuators, these tubes can restrain two undesired rotational motions. Regarding the manufacturing and maintenance costs, two system is more economical since it has only two hydraulic actuators unlike others.

  • PDF

Time Domain based Structural System Identification using Shaking Table Test (진동대 실험을 통한 시간영역에 기반한 시스템 식별)

  • 이상현;민경원;강경수;이명규
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2004.10a
    • /
    • pp.331-338
    • /
    • 2004
  • In this paper, stiffness and damping matrices are experimentally constructed using structural modal information on frequencies, damping ratios and modal vectors, which are obtained by shaking table tests. The acceleration of the shaking table is used as the input signal, and the resulting acceleration of each floor is measured as output signal. The characteristic and limitation of modal information from shaking table test are obtained by Common Based-normalized System Identification(CBSI) technique which is based on time domain information.

  • PDF

Seismic Performance Evaluation of Non-seismic T-bar type Steel-Panel Suspended Ceiling using Shaking Table Test (비내진 상세를 갖는 금속마감패널 천장시스템의 진동대 실험을 통한 내진성능평가)

  • Lee, Jae-Sub;In, Sung-Woo;Jung, Dam-I;Lee, Doo-Yong;Lee, Sang-Hyen;Cho, Bong-Ho
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.35 no.10
    • /
    • pp.171-180
    • /
    • 2019
  • In Korea, the seismic design of non-structural elements was interested by Earthquake of the 2016 Gyeong-ju and 2017 Po-hang. Among the non-structural elements, the ceiling system with steel panel used in Po-hang station showed failure examples of non-seismic design ceiling. In this study, the seismic performance of suspended ceiling with steel-panel, such as those used in Po-hang Station, was evaluated by shaking table tests. The shaking table tests were performed in accordance with the ICC-ES AC156 standard with floor acceleration being applied horizontally in one direction using a $3.3{\times}3.3m^2$ frame. The ceiling system consists of steel-panels, carrying channels, main and cross T-bars, and anti-falling clips. The anti-falling clip prevents the steel panel falling completely. The shaking table test confirmed that the damage at the previous stage had a direct impact on the damage state at the next stage. Through the shaking table test, the damage state of the T-bar type steel-panel suspended ceiling system was defined.

Shake Table Tests for the Evaluation of Seismic Behavior of RC piers (RC 교각의 내진거동 평가를 위한 진동대 실험)

  • Chung, Young-Soo;Shim, Chang-Su;Park, Chang-Kyu;Park, Chang-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.85-88
    • /
    • 2006
  • This paper deals with shaking table tests on RC piers to evaluate the seismic performance under near fault motion. Small scale models were fabricated and axial force was applied by introducing prestress at the centroid of the column section. Mass effect of the superstructures was simulated by mass frame which was linked with a pier model by steel bars because of the limited payload of shaking table. Friction of the mass frame when it moves was minimized by special details and it was proved before tests. Scale factor of the RC piers was 4.25. Main parameters of the test were details of reinforcements. After verifying the results of shaking table tests, seismic performance was evaluated by increasing the acceleration of the near fault motion.

  • PDF

A Study on Stability of Earthquake in Estuary Barrage through Shaking Table Test (실내 진동대 실험을 통한 하구둑 구조물의 내진 안정성에 관한 연구)

  • Shin, Eun-Chul;Kang, Hyoun-Hoi;Ryu, Byung-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2010.09b
    • /
    • pp.38-44
    • /
    • 2010
  • Shaking table tests were performed to reproduce the dynamic behavior of estuary barrage and its subbase soil which can be potentially damaged during earthquake loading. For understanding the vibration effect to the ground during earthquake, the model was formulated with 1/300 scale of prototype estuary barrage and subbase soil. Scott and Iai(1989) proposed the law of the similarity for similar experimental conditions. The laboratory model shaking table test was conducted under the vibration condition of simulated earthquake of 0.154g. The horizontal displacement on the structure was measured during the shaking table test. The pore water pressure was also monitored for the underground layers of soil. The field horizontal displacement and the pore water pressure can be predicted by using the results of the laboratory shaking table test.

  • PDF