• Title/Summary/Keyword: the second derivative of photoplethysmogram waveform

Search Result 11, Processing Time 0.027 seconds

Comparison of vascular compliance between normal and replanted fingers using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상과 재접합 손가락의 혈관 탄성도 비교)

  • Kim, Sung-Woo;Kim, Jin-Tae;Hong, Hyun-Ki;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.42-44
    • /
    • 2006
  • Up to the present, finger replantation patients have complained about various symptoms because of blood circulatory failure. Objective evaluation methods for the level of the blood circulatory failures in fingers were needed other than patient's subjective symptoms and complaints. Photoplethysmogram(PPG) measured from fingers is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, vascular compliance study for finger replantation patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and replanted finger vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. For 43 finger replantation patients, the average vascular compliance of replanted finger is lower than the normal finger statistically(p=0.001). we suggested an objective evaluation of finger vascular compliance for finger replantation patients and effect of surgical operation.

  • PDF

Comparison of peripheral vascular compliance between normal and diabetic group using second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Kang, Eun-Seok;Kim, Soo-Chan;Kim, Deok-Won
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.67-69
    • /
    • 2007
  • Recently, the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular. Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal and diabetic group vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a represents vascular compliance. Study found out that when vascular compliance is decreased, b/a is increased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy is statistically lower than the normal group(p<0.05). We suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

  • PDF

Effects of Acupuncture at GV 20(Baihui) Evaluated by the Second Derivative of Photoplethysmogram Waveform under Stress (백회혈(百會穴) 자침(刺鍼)이 스트레스 상태에서의 가속도맥파에 미치는 영향)

  • Lee, Jin-Hwan;Kim, Jin-Yi;Kim, Soo-Jung;Seo, Joo-Hee;Sung, Woo-Yong
    • Journal of Oriental Neuropsychiatry
    • /
    • v.21 no.3
    • /
    • pp.19-27
    • /
    • 2010
  • Objectives : This study was designed to report the effect of acupuncture at GV 20(Baihui) evaluated by the second derivative of photoplethysmogram waveform(SDPTG) under stress. Methods : 15 healthy volunteers participated in this study. 1. After 5 minutes rest, mental stress was provided for 5 minutes. And then subjects rested for 15 minutes. SDPTG was recorded before and after mental stress and after 15 minutes restness. 2. After 5 minutes rest, mental stress was provided for 5 minutes. And acupuncture at GV 20 remained for 15 minutes. SDPTG was recorded before and after mental stress and after 15 minutes acupuncture. Results : 1. Mental Stress didn't make significant change at SDPTG. 2. In a comparison of pre-acupuncture and post-acupuncture at the GV 20, b/a ratio(P<0.05) and Sano aging index(P<0.05) was decreased significantly. Conclusions : We concluded that acupuncture at the GV 20 may be effective method to recover vascular function.

Elevated Levels of Serum Lipids Accelerate Biological Vascular Aging evaluated by the Second Derivative of Photoplethysmogram Waveform in the Middle-Age Adults (중년 성인남녀의 혈중 지질농도가 가속도맥파에 미치는 영향)

  • Nam, Tong-Hyun;Koh, Hyung-Kyun;Park, Young-Bae
    • Journal of Acupuncture Research
    • /
    • v.19 no.3
    • /
    • pp.126-137
    • /
    • 2002
  • Objective : There is accumulating data that cardiovascular diseases, including hypertension, cerebro-vascular accident, coronary heart disease, relate to atherosclerotic changes. Increased serum levels of lipids could play a role in these circumstances. the SDPTG(the second derivative of photoplethysmogram waveform) is noninvasive methods for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. Methods : To study the effects of serum lipid levels on the SDPTG in the middle-age adults, data on serum lipid levels and the SDPTG were collected in 80 healthy middle age with varying serum lipid concentrations. Biological vascular age was assessed using the SDPTG. the SDPTG consists of an a, b, c, and d wave in systole and an e wave in diastole; an SDPTG aging index(Al) was calculated as (b-c-d-e)/a. Results : Serum triglyceride, total cholesterol, total lipid, phospholipid, HDL cholesterol levels were respectively and significantly correlated with SDPTG Al. Serum lipid levels and blood pressure are age-dependent and the SDPTG is blood pressure-dependent. Restricting analysis to age and blood pressure yield strong positive correlations between serum triglyceride, total lipid levels and SDPTG Al, but no correlations between serum total cholesterol, phospholipid levels and SDPTG Al. Conclusion : The results of this study suggest that preventive acupuncture programs or herbal medications for reducing serum lipid, especially triglyceride, levels in middle-age should include a evaluation of biological vascular aging with the second derivative of photoplethysmogram waveform.

  • PDF

Algorithm of the Detection of the Feature points using distributed feature points of the Second Derivative of Photoplethysmogram waveform (이차 미분 맥파의 변곡점 분포를 이용한 특징점 추출 알고리즘)

  • Kim, Pan-Ki;Ahn, Chang-Beom
    • Proceedings of the KIEE Conference
    • /
    • 2009.07a
    • /
    • pp.1988_1989
    • /
    • 2009
  • 본 논문은 이차 미분 맥파(SDPTG, Second Derivation of Photoplethysmogram)를 측정하여 이차 미분 맥파의 5개의 특징점을 검출하는 방법에 대한 내용을 기술한다. 본 논문에서는 측정된 신호의 신호대 잡음비(SNR)을 높이는 방법과 기존의 미분을 이용한 변곡점 추출의 한계적인 부분, 그리고 본 논문에서 제안하는 이차 미분 맥파의 특징점의 분포를 이용한 특징점 추출 알고리즘에 대해서 설명한다.

  • PDF

Assessment of Pulsed Magnetic Field Stimulus by Using Finger Photoplethysmogram and Pressure Pulse Waveform

  • Lee, Jin-Yong;Go, In-Suk;Choi, Jae-Won;Jang, Tae-Sun;Shin, Sang-Hoon;Lee, Hyun-Sook;Hwang, Do-Guwn;Kim, Sun-Wook
    • Journal of Magnetics
    • /
    • v.15 no.4
    • /
    • pp.209-212
    • /
    • 2010
  • Photoplethysmogram (PPG) and pressure pulse waveform (PPW) were compared and evaluated for the efficacy of stimulating knuckles by using the pulsed magnetic field. Both signals were observed simultaneously while the knuckles were exposed for 10 min to the pulsed magnetic field, with maximum field intensity of 0.8 T and transition time of 0.126 msec. After 5 min stimulation of the knuckles, the results showed that the aging indexes calculated from the second derivative of the PPG were increased from -1.913 to 0.072, and that of the PPW from -0.063 to 0.387. However, for the relatively long-term stimulation for 10 min, we found that the values of both the aging indexes of the second derivatives and augmentation index of the PPW returned to the starting level. The changes observed in characteristic factors such as the aging indexes of the second derivatives and augmentation index of the PPW indicate the potential of pulsed magnetic field stimulation as a therapeutic method for the treatment of patients with peripheral vascular disease.

Effects of Acupuncture at Palsa(BaXie) Evaluated by the Second Derivative of Photoplethysmogram Waveform in Hemiparetic Patients after Stroke (편마비 환자에서 팔사혈(八邪穴) 자침(刺鍼)이 가속도맥파에 미치는 영향)

  • Yeo, Kyeong-Chan;Yoon, In-Ae;Kim, Ji-Na;Bang, Sung-Pil;Moon, Sung-Il
    • Journal of Acupuncture Research
    • /
    • v.27 no.2
    • /
    • pp.23-30
    • /
    • 2010
  • Objectives : The second derivative of photoplethysmogram waveform(SDPTG) is a simple, convenient and non-invasive technique for pulse wave analysis. This study was designed to investigate the differences in the SDPTG between the affected side and the unaffected side in hemiparetic patients after stroke, and the effects of acupuncture at Palsa(BaXie) in hemiparetic patients after stroke. Methods : To evaluate the differences between the affected side and the unaffected side in hemiparetic patients after stroke, their SDPTG were recorded by using a Cardio Peri SA6000. To evaluate the effects of acupuncture at Palsa(BaXie) in 20 hemiparetic patients after stroke and 20 healthy subjects, their SDPTG were recorded 2 times(pre-acupuncture and post-acupuncture). The SDPTG consists of an a, b, c and d wave in systole and an e wave in diastole. Sano aging index was defined as (b-c-d)/a. Results : 1. The affected side in hemiparetic patients after stroke had higher average b/a ratio(p<0.05)and Sano aging index(p<0.05) than the unaffected side 2. In a comparison of pre-acupuncture and post-acupuncture at the Palsa(BaXie), b/a ratio(p<0.05) and Sano aging index(p<0.05) was decreased significantly in both hemiparetic patients and healthy subjects. Conclusions : These findings suggest that acupuncture at Palsa(BaXie) may be effective method of reverting some of the deleterious effects on vascular function produced by stroke.

Gender-Related Differences in the Second Derivative of Photoplethysmogram Waveforms in the Fourth Decade (30대 성인남녀의 성별에 따른 가속도맥파 차이에 관한 연구)

  • 남동현;박연재;박영배
    • The Journal of Korean Medicine
    • /
    • v.23 no.3
    • /
    • pp.1-10
    • /
    • 2002
  • Objective: There exist gender differences in pulsatile contour waveform. Women have a greater age-related increase in left ventricular mass than do men and more likely to experience symptomatic heart failure after infarction. SDPTG (the second derivative of photoplethysmogram waveform) is a noninvasive method for evaluating the pulse wave and is correlated with age and other risk factors for atherosclerosis. We studied the effect of gender on SDPTG and made clear why the gender differences appear. Methods: To study the effects of effect factors, including height and blood pressure, on SDPTG in the fourth decade, data on height, weight, PTD (pulse transit distance), blood pressure, serum lipid levels, and SDPTG were collected in 115 laboratory healthy men and women. SDPTG is derived from double-differential processing of fingertip photoplethysmography and consists of a, b, c, and d waves in systole and an e wave in diastole; SDPTG aging index (AI) was calculated as (b-c-d-e)/a. Results: There were significant gender-related differences of SDPTG AI, height, and blood pressure. Age, height, and mean blood pressure were respectively and significantly correlated with SDPTG AI. SDPTG is dependent upon age, height, and blood pressure. Restricting analysis to SDPTG AI, age, height, and mean blood pressure, yielded that there were gender-related differences in SDPTG AI (P<0.05) which were derived from those of height (F<0.001, df=l, P=0.994). Conclusions: These new data may help to explain previous findings about age-related differences in pulsatile contour waveforms and why gender differences of SDPTG appear. The results of this study suggest that SDPTG AI, used for evaluation of biological vascular aging, should be calibrated by height as well as age and blood pressure.

  • PDF

Comparison of peripheral vascular compliance between normal and diabetic groups using the second derivative of photoplethysmogram (PPG 2차 미분을 이용한 정상인과 당뇨병 환자의 말초혈관 탄성도 비교)

  • Kim, Sung-Woo;Lee, Ju-Hyung;Nam, Ki-Chang;Kim, Su-Chan;Cha, Eun-Jong;Kim, Deok-Won
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.15-20
    • /
    • 2007
  • Recently the prevalence rate of diabetes in Korea has been increasing rapidly due to high growth of economy and changes in dietary lifestyle. Vascular complication is one of diabetic complications which have frequently occurred by obesity, hyperglycemia and impaired glucose metabolism. Photoplethysmogram(PPG) measured from finger and toe is very useful for evaluation of vascular aging and sclerosis level since the PPG signal represents characteristics of peripheral vascular Several researchers have reported that second derivative of the finger PPG waveform was useful to evaluate vascular compliance and developed various analysis methods for vascular compliance. However, peripheral vascular compliance study for diabetic patient was never evaluated by using second derivative of PPG. Therefore, we aimed to objectively compare and to assess normal(n=850) and diabetic(n=50) groups vascular compliance using the second derivative of PPG waveform in this study. The evaluated factors of the second derivative of PPG are 'a', 'b', 'c', 'd', 'e' and b/a rapresents vascular compliance. This study found out that when vascular compliance is decreased, the absolute value of b/a is decreased. The average vascular compliance of 50 diabetic patients with neuropathy, $-1.09{\pm}0.14$ is statistically lower than the normal group, $-0.81{\pm}0.09$ (p<0.05). In conclusion, we suggest an objective evaluation of peripheral vascular compliance for diabetic patients and prevention of vascular complication.

Clinical Study on Relationship between Pattern Identifications for Stroke and the Second Derivative of Photoplethysmogram Waveform from Stroke Preventive Examination (중풍 예방 검진에서 중풍 표준화 변증과 가속도맥파의 상관성 연구)

  • Jung, So Youn;Hur, Hee Soo;Jeong, Hae Ryong;Kim, Kyoung Min;Kim, Young Kyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.230-239
    • /
    • 2015
  • This study was performed to find a relationship between each pattern identification and vascular status using the second derivative of photoplethysmogram waveform(SDPTG) indices. We analyzed 200 subjects who participated in stroke preventive examination. We classified the subjects into four groups of pattern identifications; Fire-Heat pattern(火熱證; FH), Yin Deficiency pattern(陰虛證; YD), Qi Deficiency pattern(氣虛證; QD) and Dampness-Phlegm pattern(濕痰證; DP) that based on Korean Standard Pattern Identifications for Stroke-Ⅲ. We studied a relationship between each pattern identification and the SDPTG. The total number of the subject group was 200, whereas the groups were divided into four groups; Fire-Heat pattern group(n=49), Yin Deficiency pattern(n=57), Qi Deficiency pattern(n=45), and Dampness-Phlegm pattern(n=49). b/a ratio was related with age and systolic blood pressure, c/a ratio was associated with age, systolic blood pressure, fasting blood sugar and Total cholesterol, d/a ratio was affected with age, diastolic blood pressure, and hypertension, e/a ratio was related with age and sex and SDPTG AI was associated with age. c/a ratio and d/a ratio were significantly higher in the Fire-Heat group than in the Qi Deficiency group. SDPTG AI was significantly higher in the Qi Deficiency group than in the Fire-Heat group. The Qi Deficiency group was significantly older than the Fire-Heat group and the number of hypertension patients was significantly more in the Fire-Heat group than in the Qi Deficiency group. Through this study, we found out some significant relationships between each pattern identification group and the SDPTG indices.