• Title/Summary/Keyword: upper cold low

Search Result 74, Processing Time 0.029 seconds

The Study on Cold Hypersensitivity of Upper Abdomen in Gastrointestinal Patients by Using D.I.T.I. (D.I.T.I,를 이용한 위장병(胃腸病) 환자(患者)의 상복부(上腹部) 온도(溫度) 관찰(觀察))

  • Yoon, Seong-Woo;Lee, Kyung-Sub
    • Journal of Oriental Medical Thermology
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2002
  • Cold hypersensitivity is excessive sensitivity of each body part, particularly limbs and low backs, but sometimes it affects upper abdomen region in G-I trouble patients. We conducted this research on 69 patients who came and took the both exam of gastroscopy and D.I.T.I. in Kangnam korean hospital Kyung Hee university. So, we researched the significance of temperature deviations on upper abdomen which was studied separately by gastritis group, digestive function group and H. pylori group. The result was : 1. The temperature deviation of Zhongwan(Ren12)-Danzhong(Ren17) of gastritis group was significant, it means that patients with severe gastritis have more significant cold hypersensitivity in upper abdomen than the patients who has not gastritis(p<0.005). 2. The temperature deviation of Zhongwan(Ren12)-Danzhong(Ren17) of indigestive patients in digestive function group was significant(p<0.05) 3. The temperature deviation of Zhongwan(Ren12)-Danzhong(Ren17) of H.pylori positive patients in H.pylori group was not significant. 4. The clinical relationship or tendency was not found both between H.pylori group and gastritis group and between H.pylori group and digestive function group.

  • PDF

Characteristics of Atmospheric Circulation and Heat Source related to Winter Cold Surge in Korea (한반도 겨울철 한파와 관련된 대기 순환과 열원의 특성)

  • Kim Maeng-Ki;Shin Sung-Chul;Lee Woo-Seop
    • Journal of the Korean earth science society
    • /
    • v.26 no.6
    • /
    • pp.560-572
    • /
    • 2005
  • This study investigates the characteristics of atmospheric circulation and the heat source $(Q_1)$ related to the winter cold surge in Korea from 1979 to 1999. The occurrence frequency of cold surge is about one event per year and $60\%$ of the total events occurred during the former period, before 1989. During the cold surge, the pressure pattern shows more dominant east-west dipole circulation pattern in the lower troposphere and the effect of upper level trough is stronger than normal cases. Temperature falling pattern over Korea shows that the pattern opposite to the temperature structure over Lake Baikal and temperature change has opposite signs between the low-middle level and upper level, with the boundary at 400 hPa. The analysis of heat source shows that atmospheric cooling by cold advection during the cold surge is balanced by adiabatic warming due to downward motion, indicating that the movement path of cold core is associated with that of heat sink. Therefore, the movement mechanism of the heat source and sink should be well known for understanding the maintenance mechanism of cold surge and predicting cold surges.

Using Digital Infrared Thermal Image on Diagnosing Gastrointestinal Disease (위장병(胃腸病) 환자(患者)에서 적외선체열진단기(赤外線體熱診斷器)의 활용(活用))

  • Ko, Chang-Nam;Kim, Seung-Eun;Lee, Sang-Uk;Kim, Do-Hyung;Yoon, Seong-Woo
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.4
    • /
    • pp.567-571
    • /
    • 2001
  • Objective : Cold hypersensitivity is excessive sensitivity of each body part. particularly limbs and low backs, but sometimes it affects upper abdomen region in G-I trouble patients. Methods : We conducted this research on 69 patients who came and took the both exam of gastroscopy and D.I.T.I. in kangnam korean hospital kyung hee university. So, we researched the significance of temperature deviations on upper abdomen which was studied separately by gastritis group, digestive function group and H. pylori group. Results and Conclusion : The temperature deviation of Zhongwan(Ren12)-Danzhong(Ren17) of gastritis group and indigestive patients was significant, it means that patients who have severe gastritis and indigestion have more significant cold hypersensitivity in upper abdomen. The temperature deviation of Zhongwan(Ren12)-Danzhong(Ren17) of H.pylori positive patients in H.pylori group was not significant. The clinical relationship or tendency was not found both between H.pylori group and gastritis group and between H.pylori group and digestive function group.

  • PDF

Mesoscale Features and Forecasting Guidance of Heavy Rain Types over the Korean Peninsula (한반도 호우유형의 중규모 특성 및 예보 가이던스)

  • Kim, Sunyoung;Song, Hwan-Jin;Lee, Hyesook
    • Atmosphere
    • /
    • v.29 no.4
    • /
    • pp.463-480
    • /
    • 2019
  • This study classified heavy rain types from K-means clustering for the hourly relationship between rainfall intensity and cloud top height over the Korean peninsula, and then examined their statistical characteristics for the period of June~August 2013~2018. Total rainfall amount of warm-type events was 2.65 times larger than that of the cold-type, whereas the lightning frequency divided by total rainfall for the warm-type was only 46% of the cold-type. Typical cold-type cases exhibited high cloud top height around 16 km, large reflectivity in the upper layer, and frequent lightning flashes under convectively unstable condition. Phenomenally, the cold-type cases corresponded to cloud cluster or multi-cell thunderstorms. However, two warm-type cases related to Changma and typhoon were characterized by heavy rainfall due to long duration, relatively low cloud top height and upper-level reflectivity, and the absence of lightning under the convectively neutral and extremely humid conditions. This study further confirmed that the forecast skill of rainfall could be improved by applying correction factor with the overestimation for cold-type and underestimation for warm-type cases in the Local Data Assimilation and Prediction System (LDAPS) operational model (e.g., BIAS score was improved by 5%).

Finite Element Analysis of Natural Convection of Fluids with Low Prandtl Number in a Square Enclosure (유한요소법을 이용한 정방형 밀폐용기내의 플란틀수가 낮은 유체의 자연대류에 관한 연구)

  • 김무현;이진호;강신형;손영석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.12 no.3
    • /
    • pp.541-550
    • /
    • 1988
  • Natural convection in a square enclosure was investigated numerically for low prandtl number fluids using Finite Element Method. In case of Ra=10$^{4}$, 10$^{5}$ and 10$^{6}$ the temperature gradient decreases gradually at the lower end of the hot wall(or at the upper end of the cold wall) as prandtl number decreases in the range of 0.01 .leq. Pr .leq. 10. Maximum heat transfer occurs at a somewhat higher point from the lower end of hot wall(or at somewhat lower point from the upper end of the cold wall) and it draws near to the lower end of the hot wall(or draws near to the upper end of the cold wall) with increasing prandtl number. The flow in the enclosure appears as an Unicell Pattern for Ra .leq. 10$^{4}$ and secondarily flows(or tertiary flows) appears in the core region for Ra .geq. 10$^{5}$ . The line joining the center of secondary cells skewes in a clockwise direction as the Prandtl number decreases.

Relationship between Low-level Clouds and Large-scale Environmental Conditions around the Globe

  • Sungsu Park;Chanwoo Song;Daeok Youn
    • Journal of the Korean earth science society
    • /
    • v.43 no.6
    • /
    • pp.712-736
    • /
    • 2022
  • To understand the characteristics of low-level clouds (CLs), environmental variables are composited on each CL using individual surface observations and six-hourly upper-air meteorologies around the globe. Individual CLs has its own distinct environmental conditions. Over the eastern subtropical and western North Pacific Ocean in JJA, stratocumulus (CL5) has a colder sea surface temperature (SST), stronger and lower inversion, and more low-level cloud amount (LCA) than the climatology whereas cumulus (CL12) has the opposite characteristics. Over the eastern subtropical Pacific, CL5 and CL12 are influenced by cold and warm advection within the PBL, respectively but have similar cold advection over the western North Pacific. This indicates that the fundamental physical process distinguishing CL5 and CL12 is not the horizontal temperature advection but the interaction with the underlying sea surface, i.e., the deepening-decoupling of PBL and the positive feedback between shortwave radiation and SST. Over the western North Pacific during JJA, sky-obscuring fog (CL11), no low-level cloud (CL0), and fair weather stratus (CL6) are associated with anomalous warm advection, surface-based inversion, mean upward flow, and moist mid-troposphere with the strongest anomalies for CL11 followed by CL0. Over the western North Pacific during DJF, bad weather stratus (CL7) occurs in the warm front of the extratropical cyclone with anomalous upward flow while cumulonimbus (CL39) occurs on the rear side of the cold front with anomalous downward flow. Over the tropical oceans, CL7 has strong positive (negative) anomalies of temperature in the upper troposphere (PBL), relative humidity, and surface wind speed in association with the mesoscale convective system while CL12 has the opposite anomalies and CL39 is in between.

A Case Study on the Polar Low Developed over the Sea Near Busan on 11~12 February 2011 (2011년 2월 11~12일 부산 근해에서 발달한 극저기압에 대한 사례연구)

  • Lee, Jae Gyoo;Kim, Hae-Min;Kim, Yu-Jin
    • Atmosphere
    • /
    • v.26 no.2
    • /
    • pp.301-319
    • /
    • 2016
  • The evolutionary process of the polar low, which caused the heavy snowfall in the East Coast area on 11~12 February 2011, was investigated to describe in detail using synoptic weather charts, satellite imageries, and ERA (European Centre for Medium-Range Weather Forecasts Re-Analysis) -Interim reanalysis data. It was revealed that 1) the polar low was generated over the sea near Busan where a large cyclonic shear in the inverted trough branched from the parent low existed, 2) during the developing and mature stages, there was a convectively unstable region in the lower layer around the polar low and its south side, 3) the polar low was developed in the region where the static stability in the 500~850 hPa layer was the lowest, 4) the result from the budget analysis of the vorticity equation indicated that the increase in the vorticity at the lower atmosphere, where the polar low was located, was dominated mainly by the stretching term, 5) the warm core structure of the polar low was identified in the surface-700 hPa layer during the mature stage, 6) there was a close inverse relationship between a development of the polar low and the height of the dynamic tropopause over the polar low, and 7) for generation and development of the polar low, large-scale circulation systems, such as upper cold low and its combined short wave trough, major low (parent low), and polar air outbreak, should be presented, indicating that the polar low has the nature of the baroclinic disturbance.

The Characteristics of Heavy Rainfall over the Korean Peninsular - Case Studies of Heavy Rainfall Events during the On- and Off- Changma Season- (장마기와 장마 후의 한반도 집중호우 특성 사례분석)

  • Chung, Hyo-Sang;Chung, Yun-Ang;Kim, Chang-Mo;Ryu, Chan-Su
    • Journal of Environmental Science International
    • /
    • v.21 no.12
    • /
    • pp.1511-1521
    • /
    • 2012
  • An attempt is made to analyse characteristic features of heavy rainfalls which occur at the metropolitan area of the Korean peninsular the on- and off- Changma season. For this, two representative heavy rainfall episodes are selected; one is the on-Changma season wherein a torrential rain episode happened at Goyang city on 12 July 2006, and the other is the off-Changma season, a heavy rainfall event in Seoul on 21 September 2006. Both recorded considerable amounts of precipitation, over 250mm in a half-day, which greatly exceeded the amount expected by numerical prediction models at those times, and caused great damage to property and life in the affected area. Similarities in the characteristics of both episodes were shown by; the location of upper-level jet streak and divergence fields of the upper wind over heavy rainfall areas, significantly high equivalent potential temperatures in the low atmospheric layer due to the entrainment of hot and humid air by the low-level jet, and the existence of very dry air and cold air pool in the middle layer of the atmosphere at the peak time of the rainfall events. Among them, differences in dynamic features of the low-level jet and the position of rainfall area along the low-level jet are remarkable.

Water Mass Distribution and Currents in the Vicinity of the Hupo Bank in Summer 2010 (2010년 하계 후포퇴 근해의 수괴분포와 해류)

  • Lee, Jae Chul
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.49 no.1
    • /
    • pp.61-73
    • /
    • 2016
  • Water mass distribution and currents were investigated off the east coast of Korea near the Hupo Bank using the CTD and ADCP data from June to August 2010. The typical water masses were: (1) Tsushima Surface Water (TSW) from the East Korean Warm Current (EKWC) in the surface layer, (2) a shallow thermocline at 20-30 m depth, (3) Tsushima Middle Water (TMW) of high salinity (>34.2) below the pycnocline, (4) North Korean Cold Water (NKCW) of low salinity (<34.05) and low temperature (<4°C) in the lower layer. In June, a double eddy was observed in which a cold filament intruded cyclonically from the south around a pre-existing cold-core eddy. A burst of strong southward current was recorded in mid-August due to a warm filament from the meandering EKWC. Current in the N-S direction was predominant due to topographic effects, and the direction of the northward EKWC was frequently reversed in its direction due to the eddy-filament activity, whereas the influence of the wind was not noticeable. The vertical structure of the current was of a two-layer system, with the northward EKWC in the upper layer and weak southward flows corresponding to the North Korean Cold Current (NKCC) in the deeper layer.

A Study on Flow and Mixing Caracteristics according to Hot Water Extraction (온수 추출에 따른 유동 및 혼합 특성에 관한 연구)

  • 장영근;박이동;김철주;황영규
    • Proceedings of the Korea Society for Energy Engineering kosee Conference
    • /
    • 1995.05a
    • /
    • pp.53-59
    • /
    • 1995
  • In a hot water extraction process, the flow pattern of upper region in a storage tank is a major reason of mixing between hot water and cold water. In this study, the temperature distribution in a storage tank was measured to predict the flow pattern of upper region, and the degree of stratification was analysed to the variables dominating a extraction process. And also, it was found that the degree of stratification improved expecially in a low flow rate in case of using modified distributor I(DMI) as a outlet port type.

  • PDF