• 제목/요약/키워드: width variable

검색결과 441건 처리시간 0.026초

마이크로컨트롤러를 위한 variable width system bus 제어기 구현 (Design and Implementation of variable width system bus controller for microcontroller)

  • 김도집;이문기
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2001년도 하계종합학술대회 논문집(2)
    • /
    • pp.317-320
    • /
    • 2001
  • In this paper, Variable width system bus provides a variable data bus width from 8bit to 128bit. This paper has designed variable width system bus controller for microcontroller to connect to peripherals.

  • PDF

Contact problem for a stringer plate weakened by a periodic system of variable width slots

  • Mir-Salim-zada, Minavar V.
    • Structural Engineering and Mechanics
    • /
    • 제62권6호
    • /
    • pp.719-724
    • /
    • 2017
  • We consider an elastic isotropic plate reinforced by stringers and weakened by a periodic system of rectilinear slots of variable width. The variable width of the slots is comparable with elastic deformations. We study the case when the slots faces get in contact at some area. Determination of parameters characterizing the partial closure of variable width slots is reduced to the solution of a singular integral equation. The action of the stringers is replaced with unknown equivalent concentrated forces at the points of their connection with the plate. The contact stresses and contact zone sizes are found from the solution of the singular integral equation.

IBS-2000보정기기를 이용한 체형측정방법에 따른 사상체질 진단정확률 비교연구 (Comparative Study of Sasang Constitutions Diagnostic Accuracy Rate on Measurement Method of Body Shape by IBS-2000 Compensator)

  • 설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.78-89
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method & Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated width 5 places and hand-operated circumference 8 places, Automatic width 5 places) and analyzed the anthropometric data dividing into sex, age, BMI. 1057 patients's data are used in the analysis. 3. Results and Conclusions 1) 5th Width variable which was measured during lying down was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement by Width which was measured during lying down and Width which IBS standing was 40-60%. 3) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF

주기적인 하폭 변화 수로에서 사주의 거동에 관한 수치실험 (Numerical Experiments of the Behavior of Bars in the Channels with Periodic Variable Width)

  • 장창래
    • 한국수자원학회논문집
    • /
    • 제47권1호
    • /
    • pp.37-47
    • /
    • 2014
  • 본 연구에서는 하폭의 주기적인 변화에 의하여 교호사주와 복렬사주가 발생하는 수리학적 조건에서 주기적인 하폭변화에 의한 강제사주의 형성과정과 거동 특성을 2차원 수치모형을 이용하여 파악하였다. 하폭변화의 진폭이 크면, 사주의 파장은 짧아지고, 사주의 이동성은 크게 감소하였다. 교호사주가 발생할 수 있는 영역에서는 하폭의 변화에 대하여 강제효과가 크게 작용하며, 복렬사주가 발생할 영역에서는 하폭의 변화에 의한 강제효과가 상대적으로 작은 특성을 보여주었다. 복렬사주가 발달한 조건에서는 하도변화의 진폭 대 평균하폭의 비인 무차원 진폭이 0.25로 증가할 때 사주의 이동속도는 증가하지만, 이보다 크면 사주의 이동속도가 급격하게 감소하였다. 교호사주가 발생하는 조건에서는 사주의 파장 대하폭 변화의 파장 비인 무차원 사주의 파장이 증가할수록 사주의 이동속도가 증가하지만, 무차원 사주의 파장이 1에 가까운 경우에 사주의 이동속도가 급격하게 감소하였다. 즉, 사주의 파장과 하폭의 파장이 일치할 때, 하폭변화에 의한 강제효과가 강하게 작용하여 사주가 압박되기 때문이다.

두께가 변화하는 부재 내의 혼합모드(모드 I/II) 균열의 응력확대계수 (Stress Intensity Factors of Combined Mode(Mode I/II) Crack in a Variable Thickness Plate)

  • 조명래;양원호;최용식
    • 대한기계학회논문집
    • /
    • 제17권8호
    • /
    • pp.1875-1882
    • /
    • 1993
  • Variable thickness plates are commonly used as structural members in the majority of industrial sectors. Previous fracture mechanics researches on variable thickness plates were limited to mode I loading cases. In practice, however, cracks are usually located inclined to the loading direction. In this respect, combined mode(mode I/II) stress intensity factors $K_{I}$ and $K_{II}$ at the crack tip for a variable thickness plate were obtained by 3-dimensional finite element analysis. Variable thickness plates containing a slant edge crack were chosen. The parameters used in this study were dimensionless crack $length{\lambda}$, slant $angle{\alpha}$, thickness $ratio{\beta}$ and width ratio{\omega}$. Stress intensity factors were calculated by crack opening displacement(COD) and crack sliding displacement(CSD)method proposed by Ingraffea and Manu.

탄성지반 위에 놓인 단면폭이 변화하는 수평 곡선보의 자유진동 해석 (Free Vibration Analysis of Horizontally Curved Beams with Variable Cross Sectional Width on Elastic Foundation)

  • 이병구;박광규;오상진;이태은
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.29-36
    • /
    • 2003
  • This paper deals with the free vibration analysis of horizontally circular mea beams with variable cross sectional width on elastic foundations. Taking into account the effects of rotatory inertia and shear deformation differential equations governing the free vibrations of such beams are derived, in which the Whlkler foundation model is considered as the elastic foundation. The variable width of beam is chosen as the linear equation. The differential equations are solved numerically to calculate natural frequencies. In numerical examples, the curved beam with the hinged-hinged, hinged-clamped, clamped-hinged and damped-clamped end constraints are considered The parametric studies are conducted and the lowest four frequency parameters are reported in figures as the non-dimensional forms.

  • PDF

Effects of Address Electrode Width on Address Discharge Under Variable Ambient Temperature in AC-PDP

  • Jang, Soo-Kwan;Tae, Heung-Sik;Jung, Eun-Young;Ahn, Jung-Chull;Yoo, Min-Sun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.412-415
    • /
    • 2008
  • It is known that the address discharge delay time during an address period strongly depends on the wall charge leakage. It was observed that the wall charge leakage during an address period is related to both the address width and the ambient temperature. Accordingly, the effects of address electrode width on the address discharge and wall voltage variation during an address period were examined under variable temperatures.

  • PDF

강철도교의 응력발생모형을 이용한 피로수명 추정에 관한 연구 (A Study on the Estimation of the Fatigue Life Using the Stress Generated Models in the Steel Railroad Bridges)

  • 용환선;김석태;이승수
    • 한국강구조학회 논문집
    • /
    • 제8권4호통권29호
    • /
    • pp.19-29
    • /
    • 1996
  • In this paper, it is presumed that the stress time history was generated by simulation method and investigated compatibility in regard to the reappearance of stress time history. In this procedure, the identified frequency distribution of stress range of the steel railroad bridge varies with the rational values of cut off point and bar width. Thus, we show variable aspect of the equivalent stress range results from change of cut off point and bar width. In addition, we analyze the variable of RMC and RMS model due to the cut off point and bar width of the measured stress history which influencs the prediction of fatigue life in the steel railroad bridge. The simulated stress time history is carried out by the superposition method incorporating the vertical load with rotation moment obtained from the Hermition interpolation function, and compared with developing stress results from measured maxi mum stress. Through this study, we can estimate the remaining fatigue life from a safety point of view and comparative accuracy.

  • PDF

가변폭 Double-Pulse Generator에 관한 연구 (Research on the Variable-Width and Double-Pulse Generator)

  • 이병선
    • 대한전자공학회논문지
    • /
    • 제7권4호
    • /
    • pp.6-13
    • /
    • 1970
  • 여기에 기술된 가변폭 double-pulse generator는 완전 transistor화 되어서 소형이고 사용하기 간편하다 주파수는 1KHz까지 가변할 수 있으며 pulse의 폭은 0.4μsec에서 8μsec까지, pulse의 진폭은 1V에서 10V까지, double pulse 간의 간폭은 0μsec에서 12μsec까지 가별할 수 있다. 정 또는 부의 single 또는 double pulse를 얻을 수 있다. 각단마다의 해석을 하였으며 아울러 설계식을 유도하고 실험과 비교하였다.

  • PDF

3D체형측정기와 수동측정 방법간의 사상체질별 ${\cdot}$ 성별 진단정확률 비교연구 (Diagnosis Accuracy Rate Comparative Study of Each Sasang Constitutions and Sex Distinction by Body Measurement Method between 3D Body Measuring Instrument and Hand-operating)

  • 권석동;설유경;이의주;김규곤;김종원
    • 사상체질의학회지
    • /
    • 제19권1호
    • /
    • pp.60-77
    • /
    • 2007
  • 1. Objectives This is the comparative study with hand-operated measurement method and Automatic measurement method, in order to convert the automatic measurement method. 2. Methods We measured the body of patients(hand-operated Width 5 Places and hand-operated circumference 8 place,Automatic Width 5 and automatic circumference 8 place by 3D body measuring instrument) and analyzed the anthropometric data divding into sex&age. 362 patient's data are used in the analysis. 3. Results and Conclusions 1) 1th circumference variable which standing was not a sasang constitutional difference. 2) Diagnostic accuracy rate of the body measurement was 50-80%. 3) Diagnostic accuracy rate of man is higher than Diagnostic accuracy rate of women 4) Diagnostic accuracy rate of Automatic & hand-operated measuring was not a big difference.

  • PDF