FTIR Analysis of the Aqueous Solutions of Urea and Ammonium Carbamate(AC)

요소와 암모니움 카바메이트 수용액의 FTIR 분석

  • 변홍식 (계명대학교 공과대학 공업화학과)
  • Received : 1994.03.02
  • Accepted : 1994.05.23
  • Published : 1994.08.01

Abstract

A method to analyse the concentration of mixture (AC/urea) and the concentration of urea or AC alone was developed. In this study, the decomposition of AC solution to ammonium bicarbonate was suppressed by using of 15% w/v ammonia as a solvent and the error of equilibrium point was maintained less than 1 %. Strong peaks at $1600cm^{-1}$ for urea and at $1405cm^{-1}$ for AC, corresponding to the N-H bending and symmetric carboxylate ion stretch were used to construct calibration graph and equations for the measurement of concentration. The errors of calculated concentration were ${\pm}0.1%$ w/v for AC and ${\pm}0.3%$ w/v for urea.

FTIR을 이용하여 암모니움 카바메이트와 요소의 혼합액은 물론, 각각의 농도를 분석하는 방법을 연구하였다. 본 연구에서는 15% w/v암모니아 용액을 용매로 이용하여 암모니움 카바메이트 수용액에서 발생하는 ammonium bicarbonate의 생성을 억제하였으며, 평형위치에 대한 오차를 1% 미만으로 유지하였다. $1600cm^{-1}$에서의 N-H bending에 의한 요소 흡수 피크와 $1405cm^{-1}$에서의 symmetric carboxylate ion stretch에 의한 암모니움 카바메이트 흡수 피크를 이용하여 보정 그래프를 그린 후 농도 계산식을 만들었다. 농도 측정간에 대한 오차는 암모니움 카바메이트에 대하여 ${\pm}0.1%$ w/v이었으며, 요소에 대하여 ${\pm}0.3%$ w/v이었다.

Keywords